1.
Pathol Oncol Res ; 10(3): 159-65, 2004.
Article in English | MEDLINE | ID: mdl-15448752

ABSTRACT

High-resolution, non-invasive imaging methods are required to monitor progression and regression of atherosclerotic plaques. We investigated the use of MRI to measure changes in plaque volume and vessel remodelling during progression and regression of atherosclerosis in New Zealand White rabbits. Atherosclerotic lesions were induced in the abdominal aorta by balloon injury and cholesterol feeding. MR images (2D) of the abdominal aorta were acquired with cardiac and respiratory gating using a fast spin echo sequence with and without fat-suppression. In an initial study on rabbits treated for 30 weeks we imaged the aortae with a spatial resolution of 250x250 micrometers with a slice thickness of 2 mm and achieved a close correlation between MRI-derived measurements and those made on perfusion pressure-fixed histological sections (r(1) = 0.83, slope p(1) < 0.01). We subsequently imaged 18 rabbits before and periodically during 12 weeks of cholesterol feeding (progression) followed by 12 weeks on normal diet (regression). Aortic wall (atherosclerotic lesion) volume increased significantly during progression and decreased during regression. In contrast, lumen volume increased during progression and did not change during regression. In conclusion, this study confirms that non-invasive, high-resolution MRI can be used to monitor progression and regression of atherosclerosis, each within 3 months and shows, for the first time in a short-term model, that positive remodelling occurs early during progression and persists through regression of atherosclerotic lesions.


Subject(s)
Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/pathology , Arteriosclerosis/diagnostic imaging , Arteriosclerosis/pathology , Cholesterol, Dietary , Animals , Aorta, Abdominal/metabolism , Arteriosclerosis/metabolism , Diet, Atherogenic , Disease Models, Animal , Female , Image Processing, Computer-Assisted , Immunohistochemistry , Magnetic Resonance Imaging , Rabbits , Radiography
2.
Toxicol Mech Methods ; 13(1): 39-43, 2003.
Article in English | MEDLINE | ID: mdl-20021181

ABSTRACT

The use of magnetic resonance imaging (MRI) for the measurement of cardiac output parameters in anesthetized adult male beagle dogs has been validated against a widely accepted thermodilution method. Using a multislice cine gradient echo MRI method to acquire images of the entire heart, left ventricular lumen volumes were measured at systole and diastole in seven animals. Cardiac output correlated well (R 2 = 0.88) with thermodilution measurements made in a parallel manner, both before and during acute stimulation with the inotrope dobutamine. In a chronic study of changes in cardiac morphology and function brought about by the antihypertensive minoxidil, MRI reliably detected the expected increases in stroke volume (28%) and cardiac output (58%) resulting from neural reaction to decreased blood pressure. Left ventricular lumen enlarged as well in response to fluid retention and plasma volume increase. Two in four minoxidil-treated animals also developed clear MRI-visible pericardial effusion.

SELECTION OF CITATIONS
SEARCH DETAIL
...