1.
Heart Rhythm ; 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38848856

ABSTRACT

BACKGROUND: Recurrent ventricular tachycardia (VT) can be treated by substrate modification of the myocardial scar by catheter ablation during sinus rhythm without VT induction. Better defining this arrhythmic substrate could help improve outcome and reduce ablation burden. OBJECTIVE: Limiting ablation within post-infarct scar to conduction channels within the scar to reduce VT recurrence. METHODS: Patients undergoing catheter ablation for recurrent implantable defibrillator (ICD) therapy for post-infarct VT were recruited at 5 centres. Left ventricular maps were collected on CARTO™ using a Pentaray™ catheter. Ripple mapping was used to categorise infarct scar potentials (SPs) by timing. Earliest SPs were ablated sequentially until there was loss of the terminal scar potentials without their direct ablation. The primary outcome measure was sustained VT episodes as documented by device interrogations at 1yr and was compared with VT episodes in the year pre-ablation. RESULTS: 50 pts were recruited (mean LVEF 33%±9) and 37pts (74%) met channel ablation endpoint with successful loss of latest SPs without direct ablation. There were 16 recurrences during 1yr follow up. There was a 90% reduction in VT burden from 30.2±53.9 to 3.1±7.5 (p<0.01) per patient, with a concomitant 88% reduction in appropriate shocks from 2.1±2.7 to 0.2±0.9 (p<0.01). There were 8 deaths during follow-up. Those who met channel ablation endpoint had no significant difference in mortality, recurrence or VT burden but had a significantly lower ablation burden 25.7±4.2 vs 39.9±6.1 mins (p=0.001). CONCLUSION: Scar channel ablation is feasible using ripple mapping and can be an alternative to more extensive substrate modification techniques.

2.
Article in English | MEDLINE | ID: mdl-38829298

ABSTRACT

BACKGROUND: The effect of left ventricular septal myocardial pacing (LVSP) and left bundle branch pacing (LBBP) on ventricular synchrony and left ventricular (LV) hemodynamic status is poorly understood. OBJECTIVES: The aim of this study was to investigate the impact of LVSP and LBBP vs biventricular pacing (BVP) on ventricular electrical synchrony and hemodynamic status in cardiac resynchronization therapy patients. METHODS: In cardiac resynchronization therapy candidates with LV conduction disease, ventricular synchrony was assessed by measuring QRS duration (QRSd) and using ultra-high-frequency electrocardiography. LV electrical dyssynchrony was assessed as the difference between the first activation in leads V1 to V8 to the last from leads V4 to V8. LV hemodynamic status was estimated using invasive systolic blood pressure measurement during multiple transitions between LBBP, LVSP, and BVP. RESULTS: A total of 35 patients with a mean LV ejection fraction of 29% and a mean QRSd of 168 ± 24 ms were included. Thirteen had ischemic cardiomyopathy. QRSd during BVP, LVSP, and LBBP was the same, but LBBP provided shorter LV electrical dyssynchrony than BVP (-10 ms; 95% CI: -16 to -4 ms; P = 0.001); the difference between LVSP and BVP was not significant (-5 ms; 95% CI: -12 to 1 ms; P = 0.10). LBBP was associated with higher systolic blood pressure than BVP (4%; 95% CI: 2% to 5%; P < 0.001), whereas LVSP was not (1%; 95% CI: 0% to 2%; P = 0.10). Hemodynamic differences during LBBP and LVSP vs BVP were more pronounced in nonischemic than ischemic patients. CONCLUSIONS: Ultra-high-frequency electrocardiography allowed the documentation of differences in LV synchrony between LBBP, LVSP, and BVP, which were not observed by measuring QRSd. LVSP provided the same LV synchrony and hemodynamic status as BVP, while LBBP was better than BVP in both.

3.
Heart Rhythm ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38762819

ABSTRACT

BACKGROUND: Conduction system pacing (CSP) by His bundle pacing or left bundle branch area pacing (LBBAP) is incorporated into Heart Rhythm Society guidelines for the management of bradycardia and cardiac resynchronization therapy. Despite increasing adoption with both lumenless leads and stylet-driven leads, concerns regarding the feasibility and safety of the extraction of CSP leads remain. OBJECTIVE: The aim of the study was to report on the safety, feasibility, and clinical outcomes of the extraction of CSP leads. METHODS: Patients undergoing the extraction of CSP leads from 10 international centers were enrolled in this retrospective study. Data regarding indications, lead location, lead type, extraction tools, procedural success, complications, and reimplantation in the conduction system were collected. RESULTS: Overall, 341 patients (age 69 ± 15 years; female 34%; cardiomyopathy 46%; lead dwell time 22 ± 26 months) underwent the extraction of 224 His bundle pacing and 117 LBBAP leads (lumenless leads 321; stylet-driven leads 20). Complete procedural success was achieved in 338 (99%), while clinical success was 100% with retained distal fragments in 3 patients (1%). Among patients with a lead dwell time of >6 months (6-193 months; n = 226), manual extraction was successful in 198 (87%), mechanical tools in 22 (10%), and laser in 6 (3%). Femoral tools were necessary in 3 patients. Minor complications occurred in 7 patients (2.1%). CSP reimplantation was successful in 233 of 244 patients attempted (95%). CONCLUSION: The overall success rates of the extraction of CSP leads were very high (although the LBBAP lead dwell time was <3 years), with a low need for extraction tools and minimal complication. Reimplantation in the conduction system is feasible and safe.

4.
Article in English | MEDLINE | ID: mdl-38649588

ABSTRACT

BACKGROUND: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. METHODS: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. RESULTS: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. CONCLUSIONS: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment.

5.
J Cardiovasc Dev Dis ; 11(3)2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38535115

ABSTRACT

Implantable cardioverter defibrillators (ICDs) have a long history and have progressed significantly since the 1980s. They have become an essential part of the prevention of sudden cardiac death, with a proven survival benefit in selected patient groups. However, with more recent trials and with the introduction of contemporary heart failure therapy, there is a renewed interest and new questions regarding the role of a primary prevention ICD, especially in patients with heart failure of non-ischaemic aetiology. This review looks at the history and evolution of ICDs, appraises the traditional evidence for ICDs and looks at issues relating to patient selection, risk stratification, competing risk, future directions and a proposed contemporary ICD decision framework.

6.
Eur Heart J Digit Health ; 5(1): 50-59, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38264702

ABSTRACT

Aims: Implantable cardioverter defibrillator (ICD) therapies have been associated with increased mortality and should be minimized when safe to do so. We hypothesized that machine learning-derived ventricular tachycardia (VT) cycle length (CL) variability metrics could be used to discriminate between sustained and spontaneously terminating VT. Methods and results: In this single-centre retrospective study, we analysed data from 69 VT episodes stored on ICDs from 27 patients (36 spontaneously terminating VT, 33 sustained VT). Several VT CL parameters including heart rate variability metrics were calculated. Additionally, a first order auto-regression model was fitted using the first 10 CLs. Using features derived from the first 10 CLs, a random forest classifier was used to predict VT termination. Sustained VT episodes had more stable CLs. Using data from the first 10 CLs only, there was greater CL variability in the spontaneously terminating episodes (mean of standard deviation of first 10 CLs: 20.1 ± 8.9 vs. 11.5 ± 7.8 ms, P < 0.0001). The auto-regression coefficient was significantly greater in spontaneously terminating episodes (mean auto-regression coefficient 0.39 ± 0.32 vs. 0.14 ± 0.39, P < 0.005). A random forest classifier with six features yielded an accuracy of 0.77 (95% confidence interval 0.67 to 0.87) for prediction of VT termination. Conclusion: Ventricular tachycardia CL variability and instability are associated with spontaneously terminating VT and can be used to predict spontaneous VT termination. Given the harmful effects of unnecessary ICD shocks, this machine learning model could be incorporated into ICD algorithms to defer therapies for episodes of VT that are likely to self-terminate.

7.
Heart Rhythm ; 21(5): 571-580, 2024 May.
Article in English | MEDLINE | ID: mdl-38286246

ABSTRACT

BACKGROUND: Three-dimensional (3D) mapping of the ventricular conduction system is challenging. OBJECTIVE: The purpose of this study was to use ripple mapping to distinguish conduction system activation to that of adjacent myocardium in order to characterize the conduction system in the postinfarct left ventricle (LV). METHODS: High-density mapping (PentaRay, CARTO) was performed during normal rhythm in patients undergoing ventricular tachycardia ablation. Ripple maps were viewed from the end of the P wave to QRS onset in 1-ms increments. Clusters of >3 ripple bars were interrogated for the presence of Purkinje potentials, which were tagged on the 3D geometry. Repeating this process allowed conduction system delineation. RESULTS: Maps were reviewed in 24 patients (mean 3112 ± 613 points). There were 150.9 ± 24.5 Purkinje potentials per map, at the left posterior fascicle (LPF) in 22 patients (92%) and at the left anterior fascicle (LAF) in 15 patients (63%). The LAF was shorter (41.4 vs 68.8 mm; P = .0005) and activated for a shorter duration (40.6 vs 64.9 ms; P = .002) than the LPF. Fourteen of 24 patients had left bundle branch block (LBBB), with 11 of 14 (78%) having Purkinje potential-associated breakout. There were fewer breakouts from the conduction system during LBBB (1.8 vs 3.4; 1.6 ± 0.6; P = .039) and an inverse correlation between breakout sites and QRS duration (P = .0035). CONCLUSION: We applied ripple mapping to present a detailed electroanatomic characterization of the conduction system in the postinfarct LV. Patients with broader QRS had fewer LV breakout sites from the conduction system. However, there was 3D mapping evidence of LV breakout from an intact conduction system in the majority of patients with LBBB.


Subject(s)
Catheter Ablation , Heart Conduction System , Heart Ventricles , Myocardial Infarction , Tachycardia, Ventricular , Humans , Male , Female , Heart Conduction System/physiopathology , Middle Aged , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Catheter Ablation/methods , Myocardial Infarction/physiopathology , Myocardial Infarction/complications , Electrocardiography , Purkinje Fibers/physiopathology , Aged , Imaging, Three-Dimensional , Body Surface Potential Mapping/methods
8.
Circulation ; 149(5): 379-390, 2024 01 30.
Article in English | MEDLINE | ID: mdl-37950738

ABSTRACT

BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Tachycardia, Ventricular , Humans , Cardiac Resynchronization Therapy/adverse effects , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/etiology , Ventricular Fibrillation/therapy , Heart Failure/epidemiology , Heart Failure/therapy , Electrocardiography
9.
JACC Clin Electrophysiol ; 10(1): 96-105, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37737782

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) using biventricular pacing (BVP) has been associated with greater clinical improvement in women than men. Recently, left bundle branch area pacing (LBBAP) has been shown to be an alternative form of CRT. OBJECTIVES: The purpose of this study was to investigate sex-specific outcomes for death and heart failure events in a large, international, multicenter, cohort of patients undergoing CRT with BVP or LBBAP. METHODS: In this international study of 1,778 patients (575 female and 1203 male), sex-specific survival analysis was performed to compare the effect of LBBAP-CRT relative to BVP-CRT on the combined endpoint of death or heart failure hospitalization (HFH), and secondary endpoints of HFH only, and death alone. RESULTS: Female patients were more likely to have nonischemic cardiomyopathy and left bundle branch block (LBBB) and less likely to have hypertension, diabetes, or coronary artery disease than were male patients. Overall, female patients had a better result with LBBAP compared with BVP than did male patients, with a significant 36% reduction in death or HFH (HR: 0.64; 95% CI: 0.43 to 0.97; P = 0.03) and a significant 60% reduction in HFH alone (HR: 0.4; 95% CI: 0.24 to 0.69, P < 0.01). Women had a greater reduction in death or HFH among those with nonischemic cardiomyopathy (HR: 0.45 95% CI: 0.26 to 0.79; P < 0.01) and LBBB (HR: 0.49; 95% CI: 0.27 to 0.87; P < 0.01). Sex-specific echocardiographic outcomes were better in women than in men. CONCLUSIONS: Women obtained significantly greater reductions in the combined endpoint of death or HFH (primarily driven by reduction in HFH) with LBBAP compared with BVP among patients requiring CRT than did men.


Subject(s)
Cardiac Resynchronization Therapy , Cardiomyopathies , Heart Failure , Humans , Male , Female , Cardiac Resynchronization Therapy/methods , Treatment Outcome , Bundle-Branch Block , Cardiomyopathies/therapy
10.
Article in English | MEDLINE | ID: mdl-38124803

ABSTRACT

Background: The prognostic impact of ventricular tachycardia (VT) catheter ablation is an important outstanding research question. We undertook a reconstructed individual patient data meta-analysis of randomised controlled trials comparing ablation to medical therapy in patients developing VT after MI. Methods: We systematically identified all trials comparing catheter ablation to medical therapy in patients with VT and prior MI. The prespecified primary endpoint was reconstructed individual patient assessment of all-cause mortality. Prespecified secondary endpoints included trial-level assessment of all-cause mortality, VT recurrence or defibrillator shocks and all-cause hospitalisations. Prespecified subgroup analysis was performed for ablation approaches involving only substrate modification without VT activation mapping. Sensitivity analyses were performed depending on the proportion of patients with prior MI included. Results: Eight trials, recruiting a total of 874 patients, were included. Of these 874 patients, 430 were randomised to catheter ablation and 444 were randomised to medical therapy. Catheter ablation reduced all-cause mortality compared with medical therapy when synthesising individual patient data (HR 0.63; 95% CI [0.41-0.96]; p=0.03), but not in trial-level analysis (RR 0.91; 95% CI [0.67-1.23]; p=0.53; I2=0%). Catheter ablation significantly reduced VT recurrence, defibrillator shocks and hospitalisations compared with medical therapy. Sensitivity analyses were consistent with the primary analyses. Conclusion: In patients with postinfarct VT, catheter ablation reduces mortality.

11.
Eur Heart J Suppl ; 25(Suppl G): G27-G32, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37970515

ABSTRACT

Patients with heart failure who have a prolonged PR interval are at a greater risk of adverse clinical outcomes than those with a normal PR interval. Potential mechanisms of harm relating to prolonged PR intervals include reduced ventricular filling and also the potential progression to a higher degree heart block. There has, however, been relatively little work specifically focusing on isolated PR prolongation as a therapeutic target. Secondary analyses of trials of biventricular pacing in heart failure have suggested that PR prolongation is both a prognostic marker and a promising treatment target. However, while biventricular pacing offers an improved activation pattern, it is nonetheless less physiological than native conduction in patients with a narrow QRS duration, and thus, may not be the ideal option for achieving therapeutic shortening of atrioventricular delay. Conduction system pacing aims to preserve physiological ventricular activation and may therefore be the ideal method for ventricular pacing in patients with isolated PR prolongation. Acute haemodynamic experiments and the recently reported His-optimized pacing evaluated for heart failure (HOPE HF) Randomised Controlled Trial demonstrates the potential benefits of physiological ventricular pacing on patient symptoms and left ventricular function in patients with heart failure.

12.
J R Soc Interface ; 20(207): 20230443, 2023 10.
Article in English | MEDLINE | ID: mdl-37817583

ABSTRACT

Understanding the mechanism sustaining cardiac fibrillation can facilitate the personalization of treatment. Granger causality analysis can be used to determine the existence of a hierarchical fibrillation mechanism that is more amenable to ablation treatment in cardiac time-series data. Conventional Granger causality based on linear predictability may fail if the assumption is not met or given sparsely sampled, high-dimensional data. More recently developed information theory-based causality measures could potentially provide a more accurate estimate of the nonlinear coupling. However, despite their successful application to linear and nonlinear physical systems, their use is not known in the clinical field. Partial mutual information from mixed embedding (PMIME) was implemented to identify the direct coupling of cardiac electrophysiology signals. We show that PMIME requires less data and is more robust to extrinsic confounding factors. The algorithms were then extended for efficient characterization of fibrillation organization and hierarchy using clinical high-dimensional data. We show that PMIME network measures correlate well with the spatio-temporal organization of fibrillation and demonstrated that hierarchical type of fibrillation and drivers could be identified in a subset of ventricular fibrillation patients, such that regions of high hierarchy are associated with high dominant frequency.


Subject(s)
Algorithms , Information Theory , Humans , Nonlinear Dynamics
13.
Europace ; 25(10)2023 10 05.
Article in English | MEDLINE | ID: mdl-37815462

ABSTRACT

AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Male , Humans , Aged , Female , Cardiac Pacing, Artificial/methods , Heart Conduction System , Hemodynamics , Heart Ventricles , Electrocardiography/methods
14.
Pacing Clin Electrophysiol ; 46(9): 1077-1084, 2023 09.
Article in English | MEDLINE | ID: mdl-37594233

ABSTRACT

BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.


Subject(s)
Ventricular Septum , Humans , Male , Aged , Ventricular Septum/diagnostic imaging , Bradycardia , Cicatrix , Contrast Media , Gadolinium
15.
JACC Clin Electrophysiol ; 9(11): 2358-2387, 2023 11.
Article in English | MEDLINE | ID: mdl-37589646

ABSTRACT

The field of cardiac pacing has changed rapidly in the last several years. Since the initial description of His bundle pacing targeting the conduction system, recent advances in pacing the left bundle branch and its fascicles have evolved. The field and investigators' knowledge of conduction system pacing including relevant anatomy and physiology has advanced significantly. The aim of this review is to provide a comprehensive update on recent advances in conduction system pacing.


Subject(s)
Bundle of His , Cardiac Resynchronization Therapy , Humans , Bundle-Branch Block/therapy , Electrocardiography , Heart Conduction System , Cardiac Conduction System Disease/therapy
16.
Heart Rhythm ; 20(12): 1617-1625, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37348800

ABSTRACT

BACKGROUND: Conduction system pacing (CSP), including both left bundle branch area pacing (LBBAP) and His-bundle pacing (HBP) has been proposed as an alternative therapy option for patients with indication for cardiac pacing to treat bradycardia or heart failure. OBJECTIVE: The purpose of this study was to evaluate implant success, safety, and electrical performances of HBP and LBBAP in the multinational Physiological Pacing Registry. METHODS: The international prospective observational registry included 44 sites from 16 countries globally between November 2018 and May 2021. RESULTS: Of 870 subjects enrolled, CSP lead implantation was attempted in 849 patients. Subjects with successful CSP lead implantation were followed for 6 months (5 ± 2 months). CSP lead implantation was successful in 768 patients (90.4%). Implant success was 95.2% (239/251) for LBBAP and 88.5% (529/598) for HBP (P = .002). Procedural duration and fluoroscopy duration were comparable between LBBAP and HBP (P = .537). Capture threshold at implant was 0.69 ± 0.39 V at 0.46 ± 0.15 ms in LBBAP and 1.44 ± 1.03 V at 0.71 ± 0.33 ms in HBP (P <.001). Capture threshold at 6 months was 0.79 ± 0.33 V at 0.44 ± 0.13 ms in LBBAP and 1.59 ± 0.97 V at 0.67 ± 0.31 ms in HBP (P <.001). Pacing threshold rise ≥1 V was observed at 6 months in 3 of 208 (1.4%) of LBBAP and 55 of 418 (13.2%) of HBP (P <.001). Serious adverse events related to implant procedure or CSP lead occurred in 5 of 251 (2.0%) with LBBAP and 25 of 598 (4.2%) with HBP (P = .115). CONCLUSION: This large prospective multicenter study demonstrates that CSP is technically feasible in most patients with relatively higher implant success and suggests that, with current technology, LBBAP may have better pacing parameters than HBP.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Humans , Prospective Studies , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Cardiac Conduction System Disease/etiology , Registries , Treatment Outcome
17.
J Am Coll Cardiol ; 82(3): 228-241, 2023 07 18.
Article in English | MEDLINE | ID: mdl-37220862

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular pacing (BVP) is a well established therapy in patients with reduced left ventricular ejection fraction (LVEF), heart failure, and wide QRS or expected frequent ventricular pacing. Left bundle branch area pacing (LBBAP) has recently been shown to be a safe alternative to BVP. OBJECTIVES: The aim of this study was to compare the clinical outcomes between BVP and LBBAP among patients undergoing CRT. METHODS: This observational study included patients with LVEF ≤35% who underwent BVP or LBBAP for the first time for Class I or II indications for CRT from January 2018 to June 2022 at 15 international centers. The primary outcome was the composite endpoint of time to death or heart failure hospitalization (HFH). Secondary outcomes included endpoints of death, HFH, and echocardiographic changes. RESULTS: A total of 1,778 patients met inclusion criteria: 981 BVP, 797 LBBAP. The mean age was 69 ± 12 years, 32% were female, 48% had coronary artery disease, and mean LVEF was 27% ± 6%. Paced QRS duration in LBBAP was significantly narrower than baseline (128 ± 19 ms vs 161 ± 28 ms; P < 0.001) and significantly narrower compared to BVP (144 ± 23 ms; P < 0.001). Following CRT, LVEF improved from 27% ± 6% to 41% ± 13% (P < 0.001) with LBBAP compared with an increase from 27% ± 7% to 37% ± 12% (P < 0.001) with BVP, with significantly greater change from baseline with LBBAP (13% ± 12% vs 10% ± 12%; P < 0.001). On multivariable regression analysis, the primary outcome was significantly reduced with LBBAP compared with BVP (20.8% vs 28%; HR: 1.495; 95% CI: 1.213-1.842; P < 0.001). CONCLUSIONS: LBBAP improved clinical outcomes compared with BVP in patients with CRT indications and may be a reasonable alternative to BVP.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Stroke Volume , Electrocardiography , Ventricular Function, Left , Treatment Outcome , Heart Failure/therapy
18.
Eur J Heart Fail ; 25(6): 902-911, 2023 06.
Article in English | MEDLINE | ID: mdl-37092287

ABSTRACT

AIMS: In heart failure (HF), implantable haemodynamic monitoring devices have been shown to optimize therapy, anticipating clinical decompensation and preventing hospitalization. Direct left-sided haemodynamic sensors offer theoretical benefits beyond pulmonary artery pressure monitoring systems. We evaluated the safety, usability, and performance of a novel left atrial pressure (LAP) monitoring system in HF patients. METHODS AND RESULTS: The VECTOR-HF study (NCT03775161) was a first-in-human, prospective, multicentre, single-arm, clinical trial enrolling 30 patients with HF. The device consisted of an interatrial positioned leadless sensor, able to transmit LAP data wirelessly. After 3 months, a right heart catheterization was performed to correlate mean pulmonary capillary wedge pressure (PCWP) with simultaneous mean LAP obtained from the device. Remote LAP measurements were then used to guide patient management. The miniaturized device was successfully implanted in all 30 patients, without acute major adverse cardiac and neurological events (MACNE). At 3 months, freedom from short-term MACNE was 97%. Agreement between sensor-calculated LAP and PCWP was consistent, with a mean difference of -0.22 ± 4.92 mmHg, the correlation coefficient and the Lin's concordance correlation coefficient values were equal to 0.79 (p < 0.0001) and 0.776 (95% confidence interval 0.582-0.886), respectively. Preliminary experience with V-LAP-based HF management was associated with significant improvements in New York Heart Association (NYHA) functional class (32% of patients reached NYHA class II at 6 months, p < 0.005; 60% of patients at 12 months, p < 0.005) and 6-min walk test distance (from 244.59 ± 119.59 m at baseline to 311.78 ± 129.88 m after 6 months, p < 0.05, and 343.95 ± 146.15 m after 12 months, p < 0.05). CONCLUSION: The V-LAP™ monitoring system proved to be generally safe and provided a good correlation with invasive PCWP. Initial evidence also suggests possible improvement in HF clinical symptoms.


Subject(s)
Atrial Pressure , Heart Failure , Humans , Cardiac Catheterization/methods , Prospective Studies , Pulmonary Wedge Pressure
19.
J Am Heart Assoc ; 12(8): e028661, 2023 04 18.
Article in English | MEDLINE | ID: mdl-37042261

ABSTRACT

Background Idiopathic ventricular fibrillation (VF) is a diagnosis of exclusion following normal cardiac investigations. We sought to determine if exercise-induced changes in electrical substrate could distinguish patient groups with various ventricular arrhythmic pathophysiological conditions and identify patients susceptible to VF. Methods and Results Computed tomography and exercise testing in patients wearing a 252-electrode vest were combined to determine ventricular conduction stability between rest and peak exercise, as previously described. Using ventricular conduction stability, conduction heterogeneity in idiopathic VF survivors (n=14) was compared with those surviving VF during acute ischemia with preserved ventricular function following full revascularization (n=10), patients with benign ventricular ectopy (n=11), and patients with normal hearts, no arrhythmic history, and negative Ajmaline challenge during Brugada family screening (Brugada syndrome relatives; n=11). Activation patterns in normal subjects (Brugada syndrome relatives) are preserved following exercise, with mean ventricular conduction stability of 99.2±0.9%. Increased heterogeneity of activation occurred in the idiopathic VF survivors (ventricular conduction stability: 96.9±2.3%) compared with the other groups combined (versus 98.8±1.6%; P=0.001). All groups demonstrated periodic variation in activation heterogeneity (frequency, 0.3-1 Hz), but magnitude was greater in idiopathic VF survivors than Brugada syndrome relatives or patients with ventricular ectopy (7.6±4.1%, 2.9±2.9%, and 2.8±1.2%, respectively). The cause of this periodicity is unknown and was not replicable by introducing exercise-induced noise at comparable frequencies. Conclusions In normal subjects, ventricular activation patterns change little with exercise. In contrast, patients with susceptibility to VF experience activation heterogeneity following exercise that requires further investigation as a testable manifestation of underlying myocardial abnormalities otherwise silent during routine testing.


Subject(s)
Brugada Syndrome , Ventricular Premature Complexes , Humans , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Heart Conduction System , Ventricular Premature Complexes/etiology , Ventricular Premature Complexes/complications , Electrocardiography , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/etiology , Survivors
20.
Cardiovasc Digit Health J ; 4(2): 60-67, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37101944

ABSTRACT

Background: Accurately determining arrhythmia mechanism from a 12-lead electrocardiogram (ECG) of supraventricular tachycardia can be challenging. We hypothesized a convolutional neural network (CNN) can be trained to classify atrioventricular re-entrant tachycardia (AVRT) vs atrioventricular nodal re-entrant tachycardia (AVNRT) from the 12-lead ECG, when using findings from the invasive electrophysiology (EP) study as the gold standard. Methods: We trained a CNN on data from 124 patients undergoing EP studies with a final diagnosis of AVRT or AVNRT. A total of 4962 5-second 12-lead ECG segments were used for training. Each case was labeled AVRT or AVNRT based on the findings of the EP study. The model performance was evaluated against a hold-out test set of 31 patients and compared to an existing manual algorithm. Results: The model had an accuracy of 77.4% in distinguishing between AVRT and AVNRT. The area under the receiver operating characteristic curve was 0.80. In comparison, the existing manual algorithm achieved an accuracy of 67.7% on the same test set. Saliency mapping demonstrated the network used the expected sections of the ECGs for diagnoses; these were the QRS complexes that may contain retrograde P waves. Conclusion: We describe the first neural network trained to differentiate AVRT from AVNRT. Accurate diagnosis of arrhythmia mechanism from a 12-lead ECG could aid preprocedural counseling, consent, and procedure planning. The current accuracy from our neural network is modest but may be improved with a larger training dataset.