Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J STD AIDS ; 23(9): 644-6, 2012 Sep.
Article in English | MEDLINE | ID: mdl-23033518

ABSTRACT

HIV point-of-care tests (POCTs) give occasional false positive results, causing unnecessary patient anxiety. We aimed to elicit whether false- and true-positive POCTs differed visually. Seventeen false- and 17 true-positive serum samples were randomized into pairs, comprising one false- and one true-positive sample. Two independent readers identified each POCT as negative or positive and compared line strength between pairs. Six further readers graded line strength, 0-5, from POCT photographs. All true-positive samples were identified positive and 8/17 false-positive samples negative, on repeat testing of stored sera. Eight out of the 9 remaining false-positive tests were described as having weaker pigment uptake than their paired true-positive POCT. Mean grade of line strength was 4.2 in true- and 0.9 in false-positive samples, on photographic evaluation. These results suggest false-positive POCTs may differ visually from true-positive POCTs. If larger studies confirm these findings, we may be able to alleviate anxiety in low risk patients with faintly positive POCTs awaiting their confirmatory laboratory result, where the possibility of a false-positive result could be emphasized.


Subject(s)
Chromatography, Affinity/standards , HIV Antibodies/blood , HIV Infections/blood , HIV Infections/virology , HIV-1/immunology , HIV-2/immunology , Reagent Kits, Diagnostic/virology , Chromatography, Affinity/instrumentation , Chromatography, Affinity/methods , False Positive Reactions , Humans , Point-of-Care Systems , Time Factors
2.
Opt Lett ; 22(21): 1600-2, 1997 Nov 01.
Article in English | MEDLINE | ID: mdl-18188309

ABSTRACT

We present experimental evidence to demonstrate the feasibility of a promising new quasi-phase-matching technique in AlGaAs multiple-quantum-well waveguides. Non-phase-matched second-harmonic-generation measurements indicate that, for sub-half-bandgap excitation near 1.5 microm , quantum-well intermixing by impurity-free vacancy disordering results in a reduction of the nonlinear susceptibility chi((2))(zxy) (~340 pm/V) by 17%. Relatively low intermixed waveguide losses, and the high spatial resolution of the impurity-free vacancy disordering process, suggest that periodic intermixing along the direction of propagation should lead to useful frequency-conversion efficiencies.

3.
Opt Lett ; 19(24): 2089-91, 1994 Dec 15.
Article in English | MEDLINE | ID: mdl-19855749

ABSTRACT

An optical autocorrelator grown on a (211)B GaAs substrate that uses visible surface-emitted second-harmonic generation is demonstrated. The (211)B orientation needs TE mode excitation only, thus eliminating the problem of the beating between the TE and TM modes that is required for (100)-grown devices; it also has the advantage of giving higher upconversion efficiency than (111) growth. Values of waveguide loss and the difference in the effective refractive index between the TE(0) and TE(1) modes were also obtained from the autocorrelation experiment.

SELECTION OF CITATIONS
SEARCH DETAIL
...