Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
J Appl Lab Med ; 7(3): 747-761, 2022 05 04.
Article in English | MEDLINE | ID: mdl-34993540

ABSTRACT

BACKGROUND: Acute kidney injury (AKI), a frequent and serious complication of hospitalized patients, is associated with increased mortality and morbidity. Neutrophil gelatinase-associated lipocalin (NGAL) is a biomarker for the early identification of AKI. We report a comparative laboratory verification of the Abbott Diagnostics (ARCHITECT® urine NGAL) and BioPorto Diagnostics (NGAL TestTM) assays including an assessment of the Abbott assay's performance in EDTA plasma. METHODS: Intra-/interbatch imprecision, linearity, recovery, and limit of quantitation (LoQ) were assessed and an interassay comparison performed (n = 51). Between-laboratory agreement was assessed against other laboratories using the Abbott (n = 48) and BioPorto (n = 94) assays. Plasma NGAL (pNGAL) levels were measured in non-AKI patients with a range of estimated glomerular filtration rates (n = 80). RESULTS: Coefficients of variation (CVs) for intra- and interbatch imprecision were 0.7%-12.4% and 1.9%-27.5% for the BioPorto assay, respectively, and 1.4%-6.3%/3.4%-6.8%, respectively, for the Abbott assay. The BioPorto assay exhibited a higher LoQ (27.5 ng/mL vs 1.2 ng/mL). Both assays were linear over the range 5-6000 ng/mL. Recovery of recombinant NGAL was 113.1 ± 7.1% and 96.5 ± 7.8% for the Abbott and BioPorto assays, respectively. On average, the Abbott assay gave results 9.2% lower than the BioPorto assay. Mean differences of 0.2% (Abbott) and 20.2% (BioPorto) were observed in the between-laboratory comparison. In patients without AKI, pNGAL levels were inversely proportional to eGFR. CONCLUSIONS: Performance of the Abbott and BioPorto assays was similar although the latter performed less well at lower NGAL concentrations. The Abbott assay tended to yield lower results, exhibited a lower LoQ and over-recovered NGAL. Although only Conformité Européenne-marked and marketed for use in urine, the Abbott assay demonstrated equivalent performance to the BioPorto assay with EDTA plasma.


Subject(s)
Acute Kidney Injury , Lipocalins , Acute Kidney Injury/diagnosis , Acute Kidney Injury/urine , Acute-Phase Proteins/urine , Edetic Acid , Female , Humans , Immunoassay , Lipocalin-2 , Lipocalins/urine , Male , Proto-Oncogene Proteins/urine
2.
Ann Clin Biochem ; 57(4): 312-315, 2020 07.
Article in English | MEDLINE | ID: mdl-32369399

ABSTRACT

INTRODUCTION: Laboratory comments appended on clinical biochemistry reports are common in the UK. Although popular with clinicians and the public, there is little evidence that these comments influence the clinical management of patients. METHODS: We provided reflex automated laboratory comments on all primary care lipid results including, if appropriate, recommendation of direct referral to the West Midlands Familial Hypercholesterolaemia service (WMFHS). Over a two-year period, the number GP referrals from the Wolverhampton City Clinical Commissioning Group (CCG) to the WMFHS were compared with four comparator CCGs of similar population size, who were not provided with reflex laboratory comments. RESULTS: Over the study period, the WMFHS received more referrals from Wolverhampton GPs (241) than any other comparator CCG (range 8-65) and greater than the combined referrals (172) from all four comparator CCGs. CONCLUSION: Targeted reflex laboratory comments may influence the clinical management of patients and may have a role in the identification of individuals with familial hypercholesterolaemia.


Subject(s)
Clinical Laboratory Services , General Practitioners , Hyperlipoproteinemia Type II/diagnosis , Lipids/blood , Primary Health Care , Referral and Consultation , Humans , United Kingdom
3.
J Appl Lab Med ; 3(6): 925-935, 2019 05.
Article in English | MEDLINE | ID: mdl-31639684

ABSTRACT

BACKGROUND: Potassium EDTA (kEDTA) contamination of serum samples is common, causing spurious hyperkalemia, hypozincemia, and hypocalcemia that if unrecognized may adversely affect patient care. Gross kEDTA contamination is easy to detect, but identification of spurious electrolytes due to small amounts of contamination requires measurement of serum EDTA. We validated an EDTA assay on the Abbott Architect and reassessed its value in identifying kEDTA contamination and in studying mechanisms for contamination. METHODS: Within- and between-batch imprecision, linearity, recovery, interference, and carryover were assessed. Serum supplemented with k2EDTA plasma, to mimic sample contamination, was used to study its effect on potassium, calcium, zinc, magnesium, and alkaline phosphatase. Our current laboratory protocol for identification of kEDTA contamination, based on measurement of serum calcium, was compared to that of EDTA measurement. RESULTS: The EDTA assay displayed acceptable performance characteristics. Hemoglobin was a positive interferent. EDTA was detectable in serum contaminated with 1% (v:v) k2EDTA plasma. An increase in serum potassium of 0.54 mmol/L (11.9%) was observed at a measured EDTA concentration of 0.19 mmol/L, equivalent to 3.2% (v:v) contamination. At this EDTA concentration reductions were also observed in zinc (71%), calcium (1%), alkaline phosphatase (ALP) (4%), and magnesium (2.4%). The serum EDTA assay detected contamination in 31/106 patient samples with hyperkalemia (potassium ≥6.0mmol/L), 20 of which were undetected by the current laboratory protocol. CONCLUSIONS: The EDTA assay displayed acceptable performance, with the ability to reliably measure EDTA at low concentrations. Only a small amount of kEDTA causes significant spurious hyperkalemia and is only reliably detected with EDTA measurement.


Subject(s)
Blood Specimen Collection , Edetic Acid , Equipment Contamination/prevention & control , Hyperkalemia , Hypocalcemia , Alkaline Phosphatase/blood , Anticoagulants/pharmacology , Biomarkers/blood , Blood Specimen Collection/methods , Blood Specimen Collection/standards , Calcium/blood , Clinical Laboratory Techniques/methods , Edetic Acid/pharmacology , Humans , Hyperkalemia/blood , Hyperkalemia/diagnosis , Hypocalcemia/blood , Hypocalcemia/diagnosis , Laboratory Critical Values , Magnesium/blood , Potassium/blood , Reproducibility of Results , Zinc/blood
6.
Frontline Gastroenterol ; 9(2): 87-91, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29588834

ABSTRACT

Differentiation between inflammatory bowel disease (IBD) and functional gut disorders, and the determination of mucosal disease activity in established cases of IBD remain the cornerstones of disease diagnosis and management. Non-invasive, accurate biomarkers of gut inflammation are needed due to the variability of symptoms, the inaccuracies of currently available blood markers and the cost and invasive nature of endoscopy. Numerous biomarkers have been used and/or considered with some in current use. This article reviews the current evidence base around the indications for using biomarkers and their limitations, with a particular focus on faecal calprotectin.

7.
J Clin Pathol ; 70(12): 1049-1056, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28735301

ABSTRACT

AIMS: To prospectively evaluate whether between-assay variability of different faecal calprotectin (f-Cp) assays influences diagnostic accuracy for inflammatory bowel disease (IBD) in a cohort of patients with confirmed IBD and irritable bowel syndrome (IBS). To also evaluate the diagnostic accuracy of faecal S100A12 (f-S100A12) against f-Cp in the same patient cohort and assess whether f-S100A12 offers additional diagnostic value. METHODS: F-Cp using four commercially available f-Cp assays, f-S100A12 and blood biomarkers were measured in patients, recruited from the local IBD clinic, who had established IBS or active ulcerative colitis (UC) and Crohn's disease (CD). Diagnostic sensitivities and specificities for each assay and biomarker were calculated and compared. RESULTS: Median f-Cp levels in all assays were significantly higher in UC (347-884 µg/g; n=28) and CD (377-838 µg/g; n=15) compared with IBS (6-27 µg/g; n=17). Sensitivities and specificities at 50 µg/g were 94%-100% and 82%-100%, respectively. Median f-S100A12 levels were significantly higher in UC (81.0 µg/g; IQR 38.3-159.8) and CD (47.2 µg/g; IQR 5.3-108.9) compared with IBS (0.7 µg/g; IQR 0.5-0.8). At 2.8 µg/g, f-S100A12 had a sensitivity of 97% and specificity of 94%. The blood biomarkers demonstrated sensitivities and specificities of 44%-63% and 80%-92%, respectively. CONCLUSIONS: The diagnostic sensitivity of the calprotectin assays was similar despite inter-kit variability in absolute values. There is a need for f-Cp assay standardisation, but in its absence assay-specific cut-off values may optimise their diagnostic performance. F-S100A12 demonstrated comparable sensitivity and specificity to f-Cp and although a research tool at present, may have a future role to play in the diagnosis and management of these patients.


Subject(s)
Colitis, Ulcerative/diagnosis , Crohn Disease/diagnosis , Feces/chemistry , Leukocyte L1 Antigen Complex/analysis , S100A12 Protein/analysis , Adolescent , Adult , Aged , Area Under Curve , Biomarkers/analysis , Colitis, Ulcerative/metabolism , Colitis, Ulcerative/therapy , Crohn Disease/metabolism , Crohn Disease/therapy , Female , Humans , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Prospective Studies , ROC Curve , Reagent Kits, Diagnostic , Reproducibility of Results , Young Adult
9.
J Clin Pathol ; 67(6): 535-9, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24711512

ABSTRACT

AIMS: Lipid point-of-care testing (POCT) analysers are being used to screen target populations to identify individuals at high risk of developing cardiovascular disease (CVD) as part of the National Health Service (NHS) Health Checks programme. We evaluated the performance of the Cholestech LDX and CardioChek PA POCT analysers against laboratory methods in CVD risk assessment. METHODS: Ten-year QRISK2, Joint British Societies' II (JBSII), and Framingham CVD risk scores were calculated for subjects recruited from Wolverhampton City PCT community NHS Health Check clinics. CVD risk scores derived using POCT capillary whole blood total cholesterol and HDL-cholesterol measurements were compared with those derived from the laboratory analysis of paired venous serum samples. Data from subjects with diabetes, overt CVD, and those who did not meet the risk algorithm age criteria were excluded. RESULTS: All subjects classified as high risk (risk score >20%) by the three risk algorithms on the basis of the laboratory results were correctly identified by the LDX. One (2.2%) and four (7.0%) moderate-risk subjects were misclassified by the LDX as high risk, using the JBSII and Framingham risk algorithms, respectively. The CardioChek identified all subjects classed as high risk by QRISK2, but failed to identify 6/31 (19.4%) and 3/19 (15.8%) of subjects classed as high risk by the Framingham and JBSII algorithms, respectively. The CardioChek, however, did not misclassify any moderate-risk subjects as high risk. CONCLUSIONS: Identification of subjects at risk of CVD depends on the cardiovascular risk algorithm and also on the performance of the POCT device.


Subject(s)
Blood Chemical Analysis/instrumentation , Cardiovascular Diseases/etiology , Cholesterol/blood , Dyslipidemias/blood , Point-of-Care Systems , Adult , Aged , Algorithms , Biomarkers/blood , Cholesterol, HDL/blood , Dyslipidemias/complications , Dyslipidemias/diagnosis , England , Equipment Design , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Risk Assessment , Risk Factors
10.
J Med Microbiol ; 63(Pt 4): 590-593, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24464697

ABSTRACT

Markers of intestinal inflammation have been proposed for inclusion in Clostridium difficile diagnostic algorithms. Faecal calprotectin (f-Cp), a sensitive marker of intestinal inflammation, was evaluated for utility in C. difficile diagnosis in the hospital setting. One hundred and twenty C. difficile positive and 99 C. difficile negative faecal samples of hospital-acquired diarrhoea were analysed for f-Cp using a quantitative ELISA. C. difficile positivity was confirmed using ELISAs for either toxins (n = 45) or glutamate dehydrogenase (GDH) with toxin gene confirmation (n = 75). Non-parametric ANOVA (Kruskal-Wallis) was used for data analysis. C. difficile positive samples had higher (P<0.05) median (interquartile range) f-Cp levels; 336 µg g(-1) (208-536) for toxin and 249 µg g(-1) (155-498) for GDH and toxin gene positive compared with 106 µg g(-1) (46-176) for C. difficile and culture-negative faecal samples. Five C. difficile positive samples were f-Cp negative (<50 µg g(-1)). A f-Cp concentration >50 µg g(-1) was 96 % sensitive and 26 % specific for C. difficile, with area under the ROC curve of 0.82. There is no role for f-CP alone in predicting C. difficile infection in hospital-acquired diarrhoea due to its low specificity.


Subject(s)
Clostridioides difficile/isolation & purification , Clostridium Infections/diagnosis , Diagnostic Tests, Routine/methods , Diarrhea/diagnosis , Feces/chemistry , Leukocyte L1 Antigen Complex/analysis , Adult , Aged , Aged, 80 and over , Bacterial Toxins/analysis , Enzyme-Linked Immunosorbent Assay/methods , Female , Humans , Male , Middle Aged , ROC Curve , Sensitivity and Specificity , Young Adult
11.
Ann Clin Biochem ; 51(Pt 1): 54-67, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23880620

ABSTRACT

BACKGROUND: Combined lipid and glucose point-of-care testing (POCT) devices could facilitate widespread population screening for cardiovascular disease (CVD) and diabetes as part of the NHS Vascular Risk Assessment and Management Program (NHS Health Checks). An evaluation of the Cholestech LDX and CardioChek PA POCT analysers was performed in collaboration with the Wolverhampton City Primary Care Trust (PCT). METHODS: Intra-/inter-batch imprecision, between-analyser variation and the effect of haematocrit and ascorbic acid assay interference were investigated. Accuracy of the POCT capillary whole blood total cholesterol (TC), high-density-lipoprotein cholesterol (HDL-C) and glucose measurements was estimated by comparison with those from the laboratory analysis of paired venous samples. POCT usability and clinical governance were also assessed. RESULTS: The LDX exhibited lower intra- and inter-batch imprecision and external quality assessment (EQA) scheme between-analyser variation for the measurement of TC, HDL-C and glucose when compared to the CardioChek. Ascorbic acid negatively interfered in all three assays on both POCT analysers and results reported by the CardioChek were influenced by the specimen haematocrit. The LDX displayed closer agreement with the laboratory methods for the measurement of TC and HDL-C but both the LDX and the CardioChek displayed positive bias for the measurement of glucose. CONCLUSIONS: POCT has clear advantages for delivering NHS Health Checks over the laboratory-based approach although device performance does differ. Users should also be aware of the potential clinical governance and interference issues associated with these devices.


Subject(s)
Blood Glucose , Cardiovascular Diseases/blood , Cholesterol, HDL/blood , Hematologic Tests/methods , Ascorbic Acid/administration & dosage , Cardiovascular Diseases/pathology , Hematologic Tests/instrumentation , Humans , Point-of-Care Systems , Risk Assessment
12.
J Clin Pathol ; 64(11): 1019-20, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21778299

ABSTRACT

AIM: To investigate whether incorrect order of draw of blood samples during phlebotomy causes in vitro potassium ethylenediaminetetraacetic acid EDTA (kEDTA) contamination of blood samples. METHODS: Serum kEDTA, potassium, calcium, magnesium, alkaline phosphatase, zinc and iron concentrations were measured in blood samples drawn before and after collecting blood into kEDTA containing sample tubes by an experienced phlebotomist using the Sarstedt Safety Monovette system. RESULTS: EDTA was undetectable in all samples. The concentrations of other analytes were similar in blood samples drawn before and after collection of the EDTA blood sample. CONCLUSION: Order of draw of blood samples using the Sarstedt Safety Monovette system has no effect on serum biochemistry results, when samples are taken by an experienced phlebotomist.


Subject(s)
Edetic Acid/blood , Phlebotomy/methods , Phlebotomy/standards , Adolescent , Adult , Alkaline Phosphatase/blood , Calcium/blood , Humans , Iron/blood , Magnesium/blood , Middle Aged , Posture , Potassium/blood , Young Adult , Zinc/blood
13.
Biochim Biophys Acta ; 1797(4): 494-500, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20080075

ABSTRACT

Transhydrogenase couples hydride transfer between NADH and NADP(+) to proton translocation across a membrane. The binding of Zn(2+) to the enzyme was shown previously to inhibit steps associated with proton transfer. Using Zn K-edge X-ray absorption fine structure (XAFS), we report here on the local structure of Zn(2+) bound to Escherichia coli transhydrogenase. Experiments were performed on wild-type enzyme and a mutant in which betaHis91 was replaced by Lys (betaH91K). This well-conserved His residue, located in the membrane-spanning domain of the protein, has been suggested to function in proton transfer, and to act as a ligand of the inhibitory Zn(2+). The XAFS analysis has identified a Zn(2+)-binding cluster formed by one Cys, two His, and one Asp/Glu residue, arranged in a tetrahedral geometry. The structure of the site is consistent with the notion that Zn(2+) inhibits proton translocation by competing with H(+) binding to the His residues. The same cluster of residues with very similar bond lengths best fits the spectra of wild-type transhydrogenase and betaH91K. Evidently, betaHis91 is not directly involved in Zn(2+) binding. The locus of betaHis91 and that of the Zn-binding site, although both on (or close to) the proton-transfer pathway of transhydrogenase, are spatially separate.


Subject(s)
Escherichia coli Proteins/chemistry , Mutation , NADP Transhydrogenases/chemistry , Spectrometry, X-Ray Emission/methods , Zinc/chemistry , Amino Acid Substitution , Aspartic Acid/chemistry , Aspartic Acid/genetics , Aspartic Acid/metabolism , Binding Sites/genetics , Cysteine/chemistry , Cysteine/genetics , Cysteine/metabolism , Escherichia coli Proteins/genetics , Escherichia coli Proteins/metabolism , Glutamic Acid/chemistry , Glutamic Acid/genetics , Glutamic Acid/metabolism , Histidine/chemistry , Histidine/genetics , Histidine/metabolism , Models, Molecular , NADP Transhydrogenases/genetics , NADP Transhydrogenases/metabolism , Protein Binding , Protein Structure, Tertiary , Zinc/metabolism
14.
Biochim Biophys Acta ; 1787(10): 1276-88, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19505432

ABSTRACT

Transhydrogenase couples proton translocation across a bacterial or mitochondrial membrane to the redox reaction between NAD(H) and NADP(H). Purified intact transhydrogenase from Escherichia coli was prepared, and its His tag removed. The forward and reverse transhydrogenation reactions catalysed by the enzyme were inhibited by certain metal ions but a "cyclic reaction" was stimulated. Of metal ions tested they were effective in the order Pb(2+)>Cu(2+)>Zn(2+)=Cd(2+)>Ni(2+)>Co(2+). The results suggest that the metal ions affect transhydrogenase by binding to a site in the proton-transfer pathway. Attenuated total-reflectance Fourier-transform infrared difference spectroscopy indicated the involvement of His and Asp/Glu residues in the Zn(2+)-binding site(s). A mutant in which betaHis91 in the membrane-spanning domain of transhydrogenase was replaced by Lys had enzyme activities resembling those of wild-type enzyme treated with Zn(2+). Effects of the metal ion on the mutant were much diminished but still evident. Signals in Zn(2+)-induced FTIR difference spectra of the betaHis91Lys mutant were also attributable to changes in His and Asp/Glu residues but were much smaller than those in wild-type spectra. The results support the view that betaHis91 and nearby Asp or Glu residues participate in the proton-transfer pathway of transhydrogenase.


Subject(s)
Escherichia coli/enzymology , NADP Transhydrogenases/metabolism , Protons , Zinc/metabolism , Biocatalysis/drug effects , Detergents/pharmacology , Escherichia coli/drug effects , Hydrogen-Ion Concentration , Hydrogenation/drug effects , Ions , Kinetics , Liposomes/metabolism , Models, Biological , Mutant Proteins/metabolism , NADP Transhydrogenases/isolation & purification , Nucleotides/metabolism , Spectroscopy, Fourier Transform Infrared
15.
Biochemistry ; 46(11): 3304-18, 2007 Mar 20.
Article in English | MEDLINE | ID: mdl-17323922

ABSTRACT

Transhydrogenase couples the redox reaction between NADH and NADP+ to proton translocation across a membrane. The enzyme comprises three components; dI binds NAD(H), dIII binds NADP(H), and dII spans the membrane. The 1,4,5,6-tetrahydro analogue of NADH (designated H2NADH) bound to isolated dI from Rhodospirillum rubrum transhydrogenase with similar affinity to the physiological nucleotide. Binding of either NADH or H2NADH led to closure of the dI mobile loop. The 1,4,5,6-tetrahydro analogue of NADPH (H2NADPH) bound very tightly to isolated R. rubrum dIII, but the rate constant for dissociation was greater than that for NADPH. The replacement of NADP+ on dIII either with H2NADPH or with NADPH caused a similar set of chemical shift alterations, signifying an equivalent conformational change. Despite similar binding properties to the natural nucleotides, neither H2NADH nor H2NADPH could serve as a hydride donor in transhydrogenation reactions. Mixtures of dI and dIII form dI2dIII1 complexes. The nucleotide charge distribution of complexes loaded either with H2NADH and NADP+ or with NAD+ and H2NADPH should more closely mimic the ground states for forward and reverse hydride transfer, respectively, than previously studied dead-end species. Crystal structures of such complexes at 2.6 and 2.3 A resolution are described. A transition state for hydride transfer between dihydronicotinamide and nicotinamide derivatives determined in ab initio quantum mechanical calculations resembles the organization of nucleotides in the transhydrogenase active site in the crystal structure. Molecular dynamics simulations of the enzyme indicate that the (dihydro)nicotinamide rings remain close to a ground state for hydride transfer throughout a 1.4 ns trajectory.


Subject(s)
NADP Transhydrogenases/chemistry , NADP/analogs & derivatives , NAD/analogs & derivatives , Protein Subunits/chemistry , Binding Sites , Computer Simulation , Crystallography, X-Ray , Models, Molecular , NAD/chemistry , NADP/chemistry , Nuclear Magnetic Resonance, Biomolecular , Protons , Rhodospirillum rubrum/enzymology
16.
J Chromatogr A ; 1130(1): 122-9, 2006 Oct 13.
Article in English | MEDLINE | ID: mdl-16934274

ABSTRACT

Two approaches are described and compared for the analysis of suspected allergens (SAs) in fragrance products, which are defined by the Scientific Committee of Cosmetics and Non-Food Products (SCCNFP). The first consists of a comprehensive two-dimensional gas chromatography (GC x GC) experiment using both a "conventional" non-polar/polar column combination and an "inverse" polar/non-polar column set. The second approach uses a targeted multidimensional gas chromatography (MDGC) system employing a Deans type pneumatic switch and a longitudinally modulated cryogenic system (LMCS). It was found that the conventional and inverse column sets complement each other well, providing identification of SAs present. Compounds well retained on the second dimension of one column set were the first to be eluted from the other. In some instances SAs co-eluting with matrix components on the second dimension for a given column set were clearly resolved on the other, although this has the disadvantage of requiring two analytical runs. Targeted MDGC with a non-polar/polar column set, successfully separated all SAs identified within a fragrance product. The instrument is set up in a similar fashion to a GC x GC system though with longer second dimension ((2)D) column, a cryogenic trap at the beginning of the second column, and a pneumatic switch coupling both columns. The data are easier to process than for a GC x GC experiment. The targeted MDGC method has the capacity to deliver far greater efficiency to targeted regions of a primary separation than a GC x GC experiment, whilst still maintaining overall run times similar to those of a conventional one-dimensional (1D) GC experiment. Cryogenic focussing at the beginning of the (2)D column delivers enhanced sensitivity, accurate (2)D retention times and narrow peak widths; these are responsible for an increased resolution obtained from the fast, relatively short (approximately 5 m) (2)D column. The two column set GC x GC analysis provided a quick and effective means to qualitatively determine the presence of six SAs in a commercially available air freshener, however all were not adequately resolved from matrix components. In contrast, quantitation was straightforward using the targeted MDGC method.


Subject(s)
Allergens/analysis , Chromatography, Gas/instrumentation , Chromatography, Gas/methods , Perfume/analysis , Chromatography, Gas/economics , Humans
17.
FEBS Lett ; 579(13): 2863-7, 2005 May 23.
Article in English | MEDLINE | ID: mdl-15878164

ABSTRACT

Transhydrogenase couples the redox reaction between NAD(H) and NADP(H) to proton translocation across a membrane. In membrane vesicles from Escherichia coli and Rhodospirillum rubrum, the transhydrogenase reaction (measured in the direction driving inward proton translocation) was inhibited by Zn(2+) and Cd(2+). However, depending on pH, the metal ions either had no effect on, or stimulated, "cyclic" transhydrogenation. They must, therefore, interfere specifically with steps involving binding/release of NADP(+)/NADPH: the steps thought to be associated with proton translocation. It is suggested that Zn(2+) and Cd(2+) bind in the proton-transfer pathway and block inter-conversion of states responsible for changing NADP(+)/NADPH binding energy.


Subject(s)
NADP Transhydrogenases/metabolism , NADP/metabolism , Zinc/metabolism , Ion Transport , Protein Binding , Protons
SELECTION OF CITATIONS
SEARCH DETAIL
...