Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Sci ; 106(8): 2009-2014, 2017 08.
Article in English | MEDLINE | ID: mdl-28435141

ABSTRACT

Polymorphism in active pharmaceutical ingredients can be regarded as critical for the potential that crystal form can have on the quality, efficacy, and safety of the final drug product. The current contribution aims to characterize thermodynamic interrelationship of a dimorphic co-crystal, FI and FII, involving carbamazepine (CBZ) and saccharin (SAC) molecules. Supramolecular synthesis of CBZ-SAC FI and FII has been performed using thermokinetic methods and systematically characterized by differential scanning calorimetry, powder X-ray diffraction, solubility, and slurry measurements. According to the heat of fusion rule by Burger and Ramberger, FI (ΔHfus = 121.1 J/g; melting point, 172.5°C) and FII (ΔHfus = 110.3 J/g; melting point, 164.7°C) are monotropically related. The solubility and van't Hoff plot results suggest FI stable and FII metastable forms. This study reveals that CBZ-SAC co-crystal phases, FI or FII, could be stable to heat-induced stresses; however, FII converts to FI during solution-mediated transformation.


Subject(s)
Anticonvulsants/chemistry , Carbamazepine/chemistry , Saccharin/chemistry , Sweetening Agents/chemistry , Calorimetry, Differential Scanning , Crystallization , Solubility , Thermodynamics , X-Ray Diffraction
2.
Drug Dev Ind Pharm ; 43(8): 1292-1303, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28375038

ABSTRACT

OBJECTIVE: The present study was aimed to investigate the effect of salient microneedle (MN) geometry parameters like length, density, shape and type on transdermal permeation enhancement of Zolmitriptan (ZMT). METHODS: Two types of MN devices viz. AdminPatch® arrays (ADM) (0.6, 0.9, 1.2 and 1.5 mm lengths) and laboratory fabricated polymeric MNs (PM) of 0.6 mm length were employed. In the case of PMs, arrays were applied thrice at different places within a 1.77 cm2 skin area (PM-3) to maintain the MN density closer to 0.6 mm ADM. Scaling analyses was done using dimensionless parameters like concentration of ZMT (Ct/Cs), thickness (h/L) and surface area of the skin (Sa/L2). RESULTS: Micro-injection molding technique was employed to fabricate PM. Histological studies revealed that the PM, owing to their geometry/design, formed wider and deeper microconduits when compared to ADM of similar length. Approximately 3.17- and 3.65-fold increase in ZMT flux values were observed with 1.5 mm ADM and PM-3 applications when compared to the passive studies. Good correlations were observed between different dimensionless parameters with scaling analyses. Numerical simulations, using MATLAB and COMSOL software, based on experimental data and histological images provided information regarding the ZMT skin distribution after MN application. DISCUSSION: Both from experimental studies and simulations, it was inferred that PM were more effective in enhancing the transdermal delivery of ZMT when compared to ADM. CONCLUSIONS: The study suggests that MN application enhances the ZMT transdermal permeation and the geometrical parameters of MNs play an important role in the degree of such enhancement.


Subject(s)
Drug Delivery Systems/methods , Microinjections/methods , Oxazolidinones/administration & dosage , Tryptamines/administration & dosage , Administration, Cutaneous , Needles , Oxazolidinones/chemistry , Oxazolidinones/pharmacokinetics , Permeability , Skin Absorption , Tryptamines/chemistry , Tryptamines/pharmacokinetics
3.
Drug Deliv Transl Res ; 7(3): 383-394, 2017 06.
Article in English | MEDLINE | ID: mdl-28160258

ABSTRACT

The present study aimed to investigate the effect of microneedle (MN) geometry parameters like length, density, shape and type on transdermal permeation enhancement of amlodipine (AMLO). Two types of MN devices viz. AdminPatch® arrays (ADM) (0.6, 1.2 and 1.5 mm lengths) and laboratory-fabricated polymeric MNs (PM) of 0.6 mm length were employed. In the case of PMs, arrays were applied thrice at different places within a 1.77-cm2 skin area (PM-3) to maintain the MN density closer to 0.6 mm ADM. Scaling analyses were done using dimensionless parameters like concentration of AMLO (Ct/Cs), thickness (h/L) and surface area of the skin (Sa/L2). Microinjection moulding technique was employed to fabricate PM. Histological studies revealed that the PM, owing to their geometry/design, formed wider and deeper microconduits when compared to ADM of similar length. Approximately 6.84- and 6.11-fold increase in the cumulative amount (48 h) of AMLO permeated was observed with 1.5 mm ADM and PM-3 treatments respectively, when compared to passive permeation amounts. Good correlations (R 2 > 0.89) were observed between different dimensionless parameters with scaling analyses. The enhancement in AMLO permeation was found to be in the order of 1.5 mm ADM ≥ PM-3 > 1.2 mm ADM > 0.6 mm ADM ≥PM-1 > passive. The study suggests that MN application enhances the AMLO transdermal permeation and the geometrical parameters of MNs play an important role in the degree of such enhancement.


Subject(s)
Amlodipine/administration & dosage , Antihypertensive Agents/administration & dosage , Drug Delivery Systems , Amlodipine/pharmacokinetics , Animals , Antihypertensive Agents/pharmacokinetics , Benzophenones , In Vitro Techniques , Ketones , Microinjections , Needles , Permeability , Polyethylene Glycols , Polymers , Skin/metabolism , Skin Absorption , Swine
4.
AAPS PharmSciTech ; 18(5): 1495-1506, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28078629

ABSTRACT

The present study was aimed to investigate the effect of salient microneedle (MN) geometry parameters like length, density, shape and type on transdermal permeation of rizatriptan (RIZ). Studies were carried out using two types of MN devices viz. AdminPatch® arrays (ADM) (0.6, 0.9, 1.2 and 1.5 mm lengths) and laboratory-fabricated polymeric MNs (PMs) of 0.6 mm length. In the case of the PMs, arrays were applied three times at different places within a 1.77-cm2 skin area (PM-3) to maintain the MN density closer to 0.6 mm ADM. Histological studies revealed that PM, owing to their geometry/design, formed wider and deeper microconduits when compared to ADM of similar length. Approximately 4.9- and 4.2-fold increases in the RIZ steady-state flux values were observed with 1.5 mm ADM and PM-3 applications when compared to the passive studies. A good correlation between different dimensionless parameters like the amount of RIZ permeated (C t /C s), thickness (h/L) and surface area (S a/L 2) of the skin was observed with scaling analyses. Numerical simulations provided further information regarding the distribution of RIZ in MN-treated skin after application of different MNs. Overall, the study suggests that MN application enhances the RIZ transdermal permeation and the geometrical parameters of MNs play an important role in the degree enhancement.


Subject(s)
Needles/standards , Triazoles , Tryptamines , Administration, Cutaneous , Drug Delivery Systems/instrumentation , Numerical Analysis, Computer-Assisted , Serotonin Receptor Agonists/chemistry , Serotonin Receptor Agonists/pharmacokinetics , Skin/pathology , Skin Absorption , Triazoles/chemistry , Triazoles/pharmacokinetics , Tryptamines/chemistry , Tryptamines/pharmacokinetics
5.
Pharmaceutics ; 7(4): 471-85, 2015 Oct 30.
Article in English | MEDLINE | ID: mdl-26529005

ABSTRACT

Plasma technology has been widely used to increase the surface energy of the polymer surfaces for many industrial applications; in particular to increase in wettability. The present work was carried out to investigate how surface modification using plasma treatment modifies the surface energy of micro-injection moulded microneedles and its influence on drug delivery. Microneedles of polyether ether ketone and polycarbonate and have been manufactured using micro-injection moulding and samples from each production batch have been subsequently subjected to a range of plasma treatment. These samples were coated with bovine serum albumin to study the protein adsorption on these treated polymer surfaces. Sample surfaces structures, before and after treatment, were studied using atomic force microscope and surface energies have been obtained using contact angle measurement and calculated using the Owens-Wendt theory. Adsorption performance of bovine serum albumin and release kinetics for each sample set was assessed using a Franz diffusion cell. Results indicate that plasma treatment significantly increases the surface energy and roughness of the microneedles resulting in better adsorption and release of BSA.

SELECTION OF CITATIONS
SEARCH DETAIL
...