1.
Microvasc Res ; 118: 69-81, 2018 07.
Article in English | MEDLINE | ID: mdl-29522755

ABSTRACT

Arterial thrombus formation is directly related to the mechanical shear experienced by platelets within flow. High shear strain rates (SSRs) and large shear gradients cause platelet activation, aggregation and production of thrombus. This study, for the first time, investigates the influence of pulsatile flow on local haemodynamics within sutured microarterial anastomoses. We measured physiological arterial waveform velocities experimentally using Doppler ultrasound velocimetry, and a representative example was applied to a realistic sutured microarterial geometry. Computational geometries were created using measurements taken from sutured chicken femoral arteries. Arterial SSRs were predicted using computational fluid dynamics (CFD) software, to indicate the potential for platelet activation, deposition and thrombus formation. Predictions of steady and sinusoidal inputs were compared to analyse whether the addition of physiological pulse characteristics affects local intravascular flow characteristics. Simulations were designed to evaluate flow in pristine and hand-sutured microarterial anastomoses, each with a steady-state and sinusoidal pulse component. The presence of sutures increased SSRmax in the anastomotic region by factors of 2.1 and 2.3 in steady-state and pulsatile flows respectively, when compared to a pristine vessel. SSR values seen in these simulations are analogous to the presence of moderate arterial stenosis. Steady-state simulations, driven by a constant inflow velocity equal to the peak systolic velocity (PSV) of the measured pulsatile flow, underestimated SSRs by ∼ 9% in pristine, and ∼ 19% in sutured vessels compared with a realistic pulse. Sinusoidal flows, with equivalent frequency and amplitude to a measured arterial waveform, represent a slight improvement on steady-state simulations, but still SSRs are underestimated by 1-2%. We recommend using a measured arterial waveform, of the form presented here, for simulating pulsatile flows in vessels of this nature. Under realistic pulsatile flow, shear gradients across microvascular sutures are high, of the order ∼ 7.9 × 106 m-1 s-1, which may also be associated with activation of platelets and formation of aggregates.


Subject(s)
Arterial Occlusive Diseases/etiology , Femoral Artery/surgery , Pulsatile Flow , Suture Techniques/adverse effects , Sutures/adverse effects , Thrombosis/etiology , Anastomosis, Surgical , Animals , Arterial Occlusive Diseases/blood , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/physiopathology , Blood Flow Velocity , Chickens , Computer Simulation , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Hydrodynamics , Laser-Doppler Flowmetry , Models, Cardiovascular , Platelet Aggregation , Regional Blood Flow , Risk Factors , Stress, Mechanical , Suture Techniques/instrumentation , Thrombosis/blood , Thrombosis/diagnostic imaging , Thrombosis/physiopathology , Time Factors
2.
Microvasc Res ; 105: 141-8, 2016 May.
Article in English | MEDLINE | ID: mdl-26876115

ABSTRACT

This study investigates the extent to which individual aspects of suture placement influence local haemodynamics within microarterial anastomoses. An attempt to physically quantify flow characteristics of blood past microvascular sutures is made using computational fluid dynamics (CFD) software. Particular focus has been placed on increased shear strain rate (SSR), a known precipitant of intravascular platelet activation and thrombosis. Measurements were taken from micrographs of sutured anastomoses in chicken femoral vessels, with each assessed for bite width, suture angle and suture spacing. Computational geometries were then created to represent the anastomosis. Each suture characteristic was parameterised to allow independent or simultaneous adjustment. Flow rates were obtained from anonymised Doppler ultrasound scans of analogous vessels during preoperative assessment for autologous breast reconstruction. Vessel simulations were performed in 2.5mm ducts with blood as the working fluid. Vessel walls were non-compliant and a continuous Newtonian flow was applied, in accordance with current literature. Suture bite angle and spacing had significant effects on local haemodynamics, causing notably higher local SSRs, when simulated at extremes of surgical practice. A combined simulation, encompassing subtle changes of each suture parameter simultaneously i.e. representing optimum technique, created a more favourable SSR profile. As such, haemodynamic changes associated with optimum suture placement are unlikely to influence thrombus formation significantly. These findings support adherence to the basic principles of good microsurgical practice.


Subject(s)
Computer Simulation , Femoral Artery/surgery , Hemodynamics , Mammaplasty/instrumentation , Microsurgery/instrumentation , Microvessels/surgery , Models, Cardiovascular , Suture Techniques/instrumentation , Sutures , Anastomosis, Surgical , Animals , Chickens , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiology , Humans , Microvessels/diagnostic imaging , Microvessels/physiology , Regional Blood Flow , Ultrasonography, Doppler
SELECTION OF CITATIONS