1.
Sensors (Basel) ; 23(12)2023 Jun 07.
Article in English | MEDLINE | ID: mdl-37420556

ABSTRACT

We present the broadband transmission-reflection meniscus-removal method for liquid characterization in a semi-open rectangular waveguide. The algorithm utilizes 2-port scattering parameters measured with a calibrated vector network analyzer for three states of the measurement cell: empty and filled with two liquid levels. The method enables the mathematical de-embedding of a symmetrical sample of a liquid, not distorted with a meniscus, and provision of its permittivity and permeability, as well as its height. We validate the method for propan-2-ol (IPA), a 50% aqueous solution of IPA, and distilled water in the Q-band (33-50 GHz). We investigate typical problems for in-waveguide measurements, such as phase ambiguity.

2.
Sensors (Basel) ; 23(12)2023 Jun 07.
Article in English | MEDLINE | ID: mdl-37420567

ABSTRACT

We present a novel broadband permittivity characterization method for liquids measured in a semi-open vertically oriented test cell with an uncalibrated vector network analyzer. For this goal, we utilize three scattering matrices measured at different levels of liquid in the cell. With mathematical operations, we remove the effects of systematic measurement errors caused by both the vector network analyzer and a meniscus shaping the top of the liquid samples in such a type of test cell. To the best authors' knowledge, this is the first of such a calibration-independent method dealing with meniscus. We verify its validity by comparing our results with the data available in the literature and with the outcomes of our previously published calibration-dependent meniscus removal method (MR) for propan-2-ol (IPA), a 50% aqueous solution of IPA and distilled water. The new method yields results comparable with the MR method, at least for IPA and the IPA solution, revealing, however some problems when testing high-loss water samples. Nevertheless, it allows one to cut down on expenditures in the system calibration engaging skilled labor and expensive standards.


Subject(s)
2-Propanol , Water , Calibration , Reference Standards
3.
Article in English | MEDLINE | ID: mdl-34121759

ABSTRACT

We investigate the uncertainty of large-signal measurements of a microwave transistor due to variation in the load conditions at the fundamental frequency. In particular, we evaluate uncertainties in the complex frequency-domain traveling voltage waves. In our analysis, uncertainty sources typical for large-signal measurements are considered. Then, we discuss how the resultant uncertainty in the waves is dependent on a varying load reflection coefficient. For this investigation, we consider the total uncertainty of the waves and their magnitude and phase. We also show that these errors unavoidably affect the uncertainty of performance quantities, such as output power.

4.
Sensors (Basel) ; 19(9)2019 May 06.
Article in English | MEDLINE | ID: mdl-31064077

ABSTRACT

We present a new technique for broadband liquid characterization using a semi-open, vertically oriented test cell that is measured with a calibrated vector network analyzer in three states: the empty one and filled with two different volumes of the liquid under test. Using the measurements, we de-embed a transfer matrix representing a volume increment of the liquid sample and determine its column height with a novel closed-form formula. Thanks to the de-embedding, the method enables one, for the first time, to completely remove effects caused by a reproducible meniscus forming the top surface of a liquid tested in the cell and determine not only the propagation constant, but also characteristic impedance of the liquid sample, from which its permittivity and permeability are calculated. The results are highly consistent, because all the measurements are performed without disassembling the cell. We validate experimental results of the meniscus removal method by comparing them with reference data and outcomes of the Nicolson-Ross-Weir method.