1.
J Cardiovasc Electrophysiol ; 31(6): 1289-1297, 2020 06.
Article in English | MEDLINE | ID: mdl-32270538

ABSTRACT

INTRODUCTION: The VICTORY AF Study was designed to evaluate the risk of the procedure and/or device-related strokes in patients with PersAF on warfarin undergoing ablation with a phased radiofrequency (RF) system. METHODS: The VICTORY AF trial was a prospective, multicenter, single-arm, investigational study. PersAF patients on vitamin K antagonism without major structural heart disease or history of stroke/transient ischemic attack undergoing phased RF ablation for atrial fibrillation (AF) were included. The primary outcome was the incidence of the procedure and/or device-related stroke within 30 days of the ablation by a board-certified neurologist's assessment. The secondary outcomes were an acute procedural success, 6 months effectiveness (defined as the reduction in AF/atrial flutter episodes lasting ≥10 minutes by 48-hour Holter 6 months postablation) and the number of patients with pulmonary vein (PV) stenosis. RESULTS: A total of 129 (108 PersAF, 21 long-standing PersAF) patients were treated (mean age: 60.6 ± 7.7; 79.8% male, 54.3% CHA2Ds2-VASc score ≥ 2). Two nondisabling strokes were reported (1.6%); one before discharge and the second diagnosed at the 30-day visit. Due to slow enrollment, the study was terminated before reaching the 95% one-sided upper confidence boundary for stroke incidence. Acute procedural success was 93.8%, and at 6 months, 72.8% of patients demonstrated ≥90% reduction in AF burden, 78.9% were off all antiarrhythmic drugs. There were no patients with PV stenosis of greater than 70%. CONCLUSIONS: VICTORY AF demonstrated a 1.6% incidence of stroke in PersAF undergoing ablation with a phased RF system which did not meet statistical confidence due to poor enrollment. The secondary outcomes suggest comparable efficacy to phased RF in the tailored treatment of permanent AF trial. Rigorous clinical evaluation of the stroke risk of new AF ablation technologies as well as restriction to Vitamin K antagonist anticoagulation appears to be unachievable goals in a clinical multicenter IDE trial of AF ablation in the current era.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Catheters , Catheter Ablation/adverse effects , Catheter Ablation/instrumentation , Electrodes , Hemorrhagic Stroke/epidemiology , Ischemic Stroke/epidemiology , Action Potentials , Aged , Anticoagulants/therapeutic use , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Female , Heart Rate , Hemorrhagic Stroke/diagnosis , Hemorrhagic Stroke/prevention & control , Humans , Incidence , Ischemic Stroke/diagnosis , Ischemic Stroke/prevention & control , Male , Middle Aged , North America/epidemiology , Prospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Warfarin/therapeutic use
2.
Pacing Clin Electrophysiol ; 40(12): 1432-1439, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28975641

ABSTRACT

BACKGROUND: Silent cerebral lesions (SCLs) are a potential complication of left atrial radiofrequency ablation (RFA) procedures for paroxysmal atrial fibrillation (PAF). We aimed to compare the incidence of SCLs in patients treated with irrigated RFA multielectrode catheters (nMARQ® Catheter group) and irrigated focal RFA catheters (NAVISTAR® THERMOCOOL® Catheter; TC group) after PAF ablation from subpopulation neurological assessment (SNA) cohorts of the REVOLUTION and reMARQable studies. METHODS: Data from SNA cohorts in the prospective, nonrandomized REVOLUTION study (March 2011-September 2013) and the prospective, randomized, controlled reMARQable study (October 2013-November 2015) were included. The incidence of SCLs was assessed pre- and postablation using magnetic resonance imaging. Neurological deficits were assessed using the National Institutes of Health Stroke Scale, modified Rankin Scale, and Montreal Cognitive Assessment. RESULTS: A total of 37 patients from REVOLUTION and 76 patients from reMARQable were included in the SNA cohort of each study. In the REVOLUTION SNA cohort, the incidence of SCLs was 21.1% (4/19) in the nMARQ® Catheter group and 5.9% (1/17) in the TC group. Findings from REVOLUTION helped inform the reMARQable study protocol's stringent anticoagulation regimen. SCL incidence was subsequently reduced in both groups (nMARQ® Catheter, 7.9%; TC, 3.3%). No permanent neurological deficits were observed. CONCLUSION: Adherence to a stringent anticoagulation regimen prior to and during ablation procedures appears to be an important factor in minimizing the risk of SCL.


Subject(s)
Anticoagulants/adverse effects , Asymptomatic Diseases , Brain Diseases/etiology , Brain Diseases/prevention & control , Catheter Ablation/adverse effects , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Atrial Fibrillation/surgery , Blood Coagulation , Brain Diseases/epidemiology , Female , Humans , Incidence , Male , Middle Aged , Postoperative Complications/epidemiology , Prospective Studies , Randomized Controlled Trials as Topic
3.
J Invasive Cardiol ; 28(5): 176-82, 2016 May.
Article in English | MEDLINE | ID: mdl-26984931

ABSTRACT

BACKGROUND: The VALUE PVI study demonstrated that atrial fibrillation (AF) ablation procedures and electrophysiology laboratory (EP lab) occupancy times were reduced for the cryoballoon compared with focal radiofrequency (RF) ablation. However, the economic impact associated with the cryoballoon procedure for hospitals has not been determined. OBJECTIVE: Assess the economic value associated with shorter AF ablation procedure times based on VALUE PVI data. METHODS AND RESULTS: A model was formulated from data from the VALUE PVI study. This model used a discrete event simulation to translate procedural efficiencies into metrics utilized by hospital administrators. A 1000-day period was simulated to determine the accrued impact of procedure time on an institution's EP lab when considering staff and hospital resources. The simulation demonstrated that procedures performed with the cryoballoon catheter resulted in several efficiencies, including: (1) a reduction of 36.2% in days with overtime (422 days RF vs 60 days cryoballoon); (2) 92.7% less cumulative overtime hours (370 hours RF vs 27 hours cryoballoon); and (3) an increase of 46.7% in days with time for an additional EP lab usage (186 days RF vs 653 days cryoballoon). Importantly, the added EP lab utilization could not support the time required for an additional AF ablation procedure. CONCLUSIONS: The discrete event simulation of the VALUE PVI data demonstrates the potential positive economic value of AF ablation procedures using the cryoballoon. These benefits include more days where overtime is avoided, fewer cumulative overtime hours, and more days with time left for additional usage of EP lab resources.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Heart Conduction System/surgery , Atrial Fibrillation/economics , Atrial Fibrillation/physiopathology , Catheter Ablation/economics , Cost-Benefit Analysis , Cryosurgery/economics , Follow-Up Studies , Heart Conduction System/physiopathology , Humans , Pulmonary Veins , Retrospective Studies , Time Factors
4.
Sci Rep ; 6: 21748, 2016 Feb 19.
Article in English | MEDLINE | ID: mdl-26892534

ABSTRACT

The programming of implantable cardioverter-defibrillators (ICDs) influences inappropriate shock rates. The aim of the study is to analyse rates of patients with appropriate and inappropriate shocks according to detection zones in the OPTION trial. All patients received dual chamber (DC) ICDs randomly assigned to be programmed either to single chamber (SC) or to DC settings including PARAD+ algorithm. In a post-hoc analysis, rates of patients with inappropriate and appropriate shocks were calculated for shocks triggered at heart rates ≥ 170 bpm (ventricular tachycardia zone) and at rates ≥ 200 bpm (ventricular fibrillation zone). In the SC group, higher rates of patients with total and inappropriate shocks were delivered at heart rates ≥ 170 bpm than at rates ≥ 200 bpm (total shocks: 21.1% vs. 16.6%; p = 0.002; inappropriate shocks: 7.6% vs. 4.5%, p = 0.016; appropriate shocks: 15.2% vs. 13.5%; p = n.s.). No such differences were observed in the DC group (total shocks: 14.3% vs. 12.6%; p = n.s.; inappropriate shocks: 3.9% vs. 3.6%; p = n.s.; appropriate shocks: 12.2% vs. 10.4%; p = n.s.). The higher frequency of patients with total shocks with SC settings than with DC settings that benefit from PARAD+ was driven by a higher percentage of patients with inappropriate shocks in the VT zone (170-200 bpm) in the SC population.


Subject(s)
Defibrillators, Implantable , Electric Countershock/instrumentation , Electric Countershock/methods , Tachycardia, Ventricular/therapy , Aged , Algorithms , Death, Sudden, Cardiac , Female , Heart Rate , Humans , Male , Middle Aged , Prospective Studies , Software , Treatment Outcome
5.
J Invasive Cardiol ; 26(6): 268-72, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24907083

ABSTRACT

BACKGROUND: Point-to-point focal radiofrequency (RF) catheter ablation for aberrant pulmonary vein triggers that manifest into atrial fibrillation (AF) is the traditional method for treating symptomatic drug-resistant paroxysmal AF (PAF) when an ablation procedure is warranted. More recently, pulmonary vein isolation (PVI) using the cryoballoon has been demonstrated to be safe and effective (STOP AF clinical trial). Currently, two small studies have reviewed the procedural efficiency when comparing cryoballoon to focal RF catheter ablation procedures; however, no multicenter study has yet reported on this comparison of the two types of ablation catheters. METHODS: A multicenter retrospective chart extraction and evaluation was conducted at seven geographically mixed cardiac care centers. The study examined procedural variables during ablation for PVI in PAF patients. RESULTS: In several procedural measurements, the two modalities were comparable in efficiencies, including: acute PVI >96%; length of hospital stay at approximately 27 hours; and about 30% usage of adenosine after procedural testing. However, when compared to RF catheters, the cryoballoon procedure demonstrated a 13% reduction in laboratory occupancy time (247 min vs 283 min), a 13% reduction in procedure time (174 min vs 200 min), and a 21% reduction in fluoroscopy time (33 min vs 42 min). Additionally, when comparing the material usage of both cryoballoon and RF catheters, the cryoballoon used more radiopaque contrast agent (78 cc vs 29 cc) while using less intraprocedural saline (1234 cc vs 2386 cc), intracardiac echocardiography (88% vs 99%), three-dimensional electroanatomic mapping (30% vs 87%), and fewer transseptal punctures (1.5 vs 1.9). CONCLUSION: This study is the first United States multicenter examination to report the procedural comparisons between the cryoballoon and focal RF catheters when used for the treatment of PAF patients. In this hospital chart review study, potential advantages were found when operating the cryoballoon with regard to hospital resource allocation. There was no statistical difference between cryoballoon and RF catheters for acute PVI success during the ablation procedure.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/statistics & numerical data , Cryosurgery/statistics & numerical data , Imaging, Three-Dimensional , Pulmonary Veins/surgery , Resource Allocation/statistics & numerical data , Atrial Fibrillation/epidemiology , Atrial Fibrillation/pathology , Cardiology Service, Hospital/statistics & numerical data , Female , Humans , Laboratories, Hospital/statistics & numerical data , Length of Stay/statistics & numerical data , Male , Middle Aged , Prospective Studies , Pulmonary Veins/pathology , Retrospective Studies , Time Factors , Treatment Outcome , United States/epidemiology
6.
J Vis Exp ; (72): e50247, 2013 Feb 26.
Article in English | MEDLINE | ID: mdl-23485956

ABSTRACT

Cryoballoon ablation (CBA) is an established therapy for atrial fibrillation (AF). Pulmonary vein (PV) occlusion is essential for achieving antral contact and PV isolation and is typically assessed by contrast injection. We present a novel method of direct pressure monitoring for assessment of PV occlusion. Transcatheter pressure is monitored during balloon advancement to the PV antrum. Pressure is recorded via a single pressure transducer connected to the inner lumen of the cryoballoon. Pressure curve characteristics are used to assess occlusion in conjunction with fluoroscopic or intracardiac echocardiography (ICE) guidance. PV occlusion is confirmed when loss of typical left atrial (LA) pressure waveform is observed with recordings of PA pressure characteristics (no A wave and rapid V wave upstroke). Complete pulmonary vein occlusion as assessed with this technique has been confirmed with concurrent contrast utilization during the initial testing of the technique and has been shown to be highly accurate and readily reproducible. We evaluated the efficacy of this novel technique in 35 patients. A total of 128 veins were assessed for occlusion with the cryoballoon utilizing the pressure monitoring technique; occlusive pressure was demonstrated in 113 veins with resultant successful pulmonary vein isolation in 111 veins (98.2%). Occlusion was confirmed with subsequent contrast injection during the initial ten procedures, after which contrast utilization was rapidly reduced or eliminated given the highly accurate identification of occlusive pressure waveform with limited initial training. Verification of PV occlusive pressure during CBA is a novel approach to assessing effective PV occlusion and it accurately predicts electrical isolation. Utilization of this method results in significant decrease in fluoroscopy time and volume of contrast.


Subject(s)
Angioplasty, Balloon/methods , Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Pulmonary Veins/surgery , Angioplasty, Balloon/instrumentation , Atrial Fibrillation/diagnostic imaging , Blood Pressure Determination , Catheter Ablation/instrumentation , Cryosurgery/instrumentation , Electrocardiography , Female , Fluoroscopy , Humans , Male , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Pulmonary Veins/diagnostic imaging , Pulmonary Veno-Occlusive Disease/diagnostic imaging , Pulmonary Veno-Occlusive Disease/etiology , Ultrasonography
7.
J Atr Fibrillation ; 6(3): 924, 2013.
Article in English | MEDLINE | ID: mdl-28496897

ABSTRACT

Background: Catheter and cryoballoon ablation are established treatments for atrial fibrillation. Frequently, substrate modification of the left atrium is performed in patients with persistent AF or evidence of left atrial adverse remodeling. We compared one year outcomes of AF ablation with substrate modification utilizing radiofrequency catheter ablation (RFA) compared to a combination of cryoballoon ablation with radiofrequency catheter ablation (HAFA). Methods: Ablation for persistent AF was performed using stand-alone catheter ablation (RFA group, n=31) or cryoballoon for pulmonary vein isolation with RFA catheter ablation for substrate modification (HAFA group, n=21) and procedural and clinical outcomes were analyzed. Pulmonary vein isolation and LA substrate modification including creation of left atrial ablation lines and/or CFAEs was performed in all patients. Patients were followed for up to one year. A three- month blinding window was applied for analysis. Results: Clinical characteristics were similar between groups. Total procedure (244.15±64.7 vs 235.5±54.6, p=0.6) and fluoroscopy time (37±15.4 vs 29.5±15.7, p=0.96) were not different between the HAFA and RFA groups, respectively. Periprocedural complications were similar among groups. AF free survival was not significantly different between Conclusions: Combined cryoballoon and catheter ablation for LA substrate modification (HAFA) has similar safety and efficacy compared to stand-alone catheter ablation for persistent AF. Recurrent atrial flutter is more frequently observed after cryoballoon ablation for persistent AF.

8.
Curr Heart Fail Rep ; 2(1): 35-9, 2005 Mar.
Article in English | MEDLINE | ID: mdl-16036049

ABSTRACT

The increasing adoption of biventricular pacing as a means to achieve interventricular, intraventricular, and atrioventricular synchronization affords clinicians a powerful nonpharmacologic tool in the treatment of congestive heart failure. Current guidelines support the use of cardiac resynchronization therapy (CRT) in patients with the combination of severe systolic ventricular dysfunction, symptomatic heart failure, and evidence of conduction delay on the surface electrocardiogram. Current research aims include investigation of differing clinical parameters and imaging techniques that will reliably differentiate patients who may or may not benefit from CRT. Furthermore, refinements in the techniques of lead placement and intrachamber timing may further improve the proportion of patients who achieve a favorable response from CRT. This article briefly reviews the history of CRT and summarizes some of the current trends and data relating to CRT.


Subject(s)
Cardiac Pacing, Artificial , Heart Failure/therapy , Cardiac Pacing, Artificial/methods , Heart Conduction System/physiopathology , Humans , Patient Selection , Practice Guidelines as Topic , Ventricular Dysfunction/therapy