Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 94(45): 15781-15789, 2022 11 15.
Article in English | MEDLINE | ID: mdl-36377427

ABSTRACT

Partitions in digital PCR (dPCR) assays do not reach the detection threshold at the same time. This heterogeneity in amplification results in intermediate endpoint fluorescence values (i.e., rain) and misclassification of partitions, which has a major impact on the accuracy of nucleic acid quantification. Rain most often results from a reduced amplification efficiency or template inaccessibility; however, exactly how these contribute to rain has not been described. We developed and experimentally validated an analytical model that mechanistically explains the relationship between amplification efficiency, template accessibility, and rain. Using Monte Carlo simulations, we show that a reduced amplification efficiency leads to broader threshold cycle (Ct) distributions that can be fitted using a log-normal probability distribution. From the fit parameters, the amplification efficiency can be calculated. Template inaccessibility, on the other hand, leads to a different rain pattern, in which a distinct exponential tail in the Ct distribution can be observed. Using our model, it is possible to determine if the amplification efficiency, template accessibility, or another source is the main contributor of rain in dPCR assays. We envision that this model will facilitate and speed up dPCR assay optimization and provide an indication for the accuracy of the assay.


Subject(s)
Rain , Polymerase Chain Reaction/methods , Monte Carlo Method
2.
Biosens Bioelectron ; 217: 114663, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36150327

ABSTRACT

The SARS-CoV-2 pandemic has highlighted the need for improved technologies to help control the spread of contagious pathogens. While rapid point-of-need testing plays a key role in strategies to rapidly identify and isolate infectious patients, current test approaches have significant shortcomings related to assay limitations and sample type. Direct quantification of viral shedding in exhaled particles may offer a better rapid testing approach, since SARS-CoV-2 is believed to spread mainly by aerosols. It assesses contagiousness directly, the sample is easy and comfortable to obtain, sampling can be standardized, and the limited sample volume lends itself to a fast and sensitive analysis. In view of these benefits, we developed and tested an approach where exhaled particles are efficiently sampled using inertial impaction in a micromachined silicon chip, followed by an RT-qPCR molecular assay to detect SARS-CoV-2 shedding. Our portable, silicon impactor allowed for the efficient capture (>85%) of respiratory particles down to 300 nm without the need for additional equipment. We demonstrate using both conventional off-chip and in-situ PCR directly on the silicon chip that sampling subjects' breath in less than a minute yields sufficient viral RNA to detect infections as early as standard sampling methods. A longitudinal study revealed clear differences in the temporal dynamics of viral load for nasopharyngeal swab, saliva, breath, and antigen tests. Overall, after an infection, the breath-based test remains positive during the first week but is the first to consistently report a negative result, putatively signalling the end of contagiousness and further emphasizing the potential of this tool to help manage the spread of airborne respiratory infections.


Subject(s)
Biosensing Techniques , COVID-19 , COVID-19/diagnosis , Humans , Longitudinal Studies , RNA, Viral/analysis , Respiratory Aerosols and Droplets , SARS-CoV-2 , Silicon
3.
Sci Rep ; 9(1): 7341, 2019 05 14.
Article in English | MEDLINE | ID: mdl-31089203

ABSTRACT

The demand to perform forensic DNA profiling outside of centralized laboratories and on the crime scene is increasing. Several criminal investigations would benefit tremendously from having DNA based information available in the first hours rather than days or weeks. However, due to the complexity and time-consuming nature of standard DNA fingerprinting methods, rapid and automated analyses are hard to achieve. We here demonstrate the implementation of an alternative DNA fingerprinting method in a single microchip. By combining PCR amplification and HyBeacon melting assays in a silicon Lab-on-a-chip (LoC), a significant step towards rapid on-site DNA fingerprinting is taken. The small form factor of a LoC reduces reagent consumption and increases portability. Additional miniaturization is achieved through an integrated heating element covering 24 parallel micro-reactors with a reaction volume of 0.14 µl each. The high level of parallelization allows the simultaneous analysis of 4 short tandem repeat (STR) loci and the amelogenin gender marker commonly included in forensic DNA analysis. A reference and crime scene sample can be analyzed simultaneously for direct comparison. Importantly, by using industry-standard semiconductor manufacturing processes, mass manufacturability can be guaranteed. Following assay design and optimization, complete 5-loci profiles could be robustly generated on-chip that are on par with those obtained using conventional benchtop real-time PCR thermal cyclers. Together, our results are an important step towards the development of commercial, mass-produced, portable devices for on-site testing in forensic DNA analysis.


Subject(s)
DNA Fingerprinting/instrumentation , Forensic Genetics/instrumentation , Lab-On-A-Chip Devices , Polymerase Chain Reaction/instrumentation , DNA/analysis , DNA/genetics , Equipment Design , Humans , Nucleic Acid Denaturation , Silicon/chemistry
4.
Sci Rep ; 8(1): 9853, 2018 06 29.
Article in English | MEDLINE | ID: mdl-29959383

ABSTRACT

The demand for solutions to perform forensic DNA profiling outside of centralized laboratories is increasing. We here demonstrate highly sensitive STR amplification using a silicon micro-PCR (µPCR) chip. Exploiting industry-standard semiconductor manufacturing processes, a device was fabricated that features a small form factor thanks to an integrated heating element covering three parallel micro-reactors with a reaction volume of 0.5 µl each. Diluted reference DNA samples (1 ng-31 pg) were amplified on the µPCR chip using the forensically validated AmpFISTR Identifier Plus kit, followed by conventional capillary electrophoresis. Complete STR profiles were generated with input DNA quantities down to 62 pg. Occasional allelic dropouts were observed from 31 pg downward. On-chip STR profiles were compared with those of identical samples amplified using a conventional thermal cycler for direct comparison of amplification sensitivity in a forensic setting. The observed sensitivity was in line with kit specifications for both µPCR and conventional PCR. Finally, a rapid amplification protocol was developed. Complete STR profiles could be generated in less than 17 minutes from as little as 125 pg template DNA. Together, our results are an important step towards the development of commercial, mass-produced, relatively cheap, handheld devices for on-site testing in forensic DNA analysis.


Subject(s)
DNA Fingerprinting/standards , Forensic Genetics/standards , Genetic Markers , Microsatellite Repeats , Polymerase Chain Reaction/methods , Silicon/chemistry , Genotype , Humans
5.
Analyst ; 139(6): 1396-402, 2014 Mar 21.
Article in English | MEDLINE | ID: mdl-24466569

ABSTRACT

We report here the fabrication, characterization, and application of a single-mode integrated optical waveguide (IOW) spectrometer capable of acquiring optical absorbance spectra of surface-immobilized molecules in the visible and ultraviolet spectral region down to 315 nm. The UV-extension of the single-mode IOW technique to shorter wavelengths was made possible by our development of a low-loss single-mode dielectric waveguide in the UV region based on an alumina film grown by atomic layer deposition (ALD) over a high quality fused silica substrate, and by our design/fabrication of a broadband waveguide coupler formed by an integrated diffraction grating combined with a highly anamorphic optical beam of large numerical aperture. As an application of the developed technology, we report here the surface adsorption process of bacteriochlorophyll a on different interfaces using its Soret absorption band centred at 370 nm. The effects of different chemical compositions at the solid-liquid interface on the adsorption and spectral properties of bacteriochlorophyll a were determined from the polarized UV-Vis IOW spectra acquired with the developed instrumentation. The spectral extension of the single-mode IOW technique into the ultraviolet region is an important advance as it enables extremely sensitive studies in key characteristics of surface molecular processes (e.g., protein unfolding and solvation of aromatic amino-acid groups under surface binding) whose spectral features are mainly located at wavelengths below the visible spectrum.


Subject(s)
Bacterial Proteins/chemistry , Bacteriochlorophyll A/chemistry , Rhodobacter sphaeroides/chemistry , Spectrophotometry, Ultraviolet/instrumentation , Aluminum Oxide/chemistry , Equipment Design , Silicon Dioxide/chemistry
6.
Thin Solid Films ; 518(17): 4935-4940, 2010 Jun 30.
Article in English | MEDLINE | ID: mdl-21359156

ABSTRACT

In this work, we report low-loss single-mode integrated optical waveguides in the near ultra-violet and visible spectral regions with aluminum oxide (Al(2)O(3)) films using an atomic layer deposition (ALD) process. Alumina films were deposited on glass and fused silica substrates by the ALD process at substrate/chamber temperatures of 200 °C and 300 °C. Transmission spectra and waveguide measurements were performed in our alumina films with thicknesses in the range of 210 - 380 nm for the optical characterization. Those measurements allowed us to determine the optical constants (n(w) and k(w)), propagation loss, and thickness of the alumina films. The experimental results from the applied techniques show good agreement and demonstrate a low-loss optical waveguide. Our alumina thin-film waveguides is well transparent in the whole visible spectral region and also in an important region of the UV; the measured propagation loss is below 4 dB/cm down to a wavelength as short as 250 nm. The low propagation loss of these alumina guiding films, in particular in the near ultra-violet region which lacks materials with high optical performance, is extremely useful for several integrated optic applications.

7.
J Phys Chem C Nanomater Interfaces ; 113(19): 8306-8312, 2009 May 14.
Article in English | MEDLINE | ID: mdl-21289870

ABSTRACT

In this work, we report experimental results on the molar absorptivity of cytochrome c adsorbed at different submonolayer levels onto an aluminum oxide waveguide surface; our data show a clear dependence of the protein optical properties on its surface density. The measurements were performed using the broadband, single-mode, integrated optical waveguide spectroscopic technique, which is an extremely sensitive tool able to reach submonolayer levels of detection required for this type of studies. This investigation focuses on the molar absorptivity at the Q-band (centered at 525 nm) and, for the first time to our knowledge, the weak charge transfer (CT) band (centered at 695 nm) of surface-adsorbed cyt c. Polarized light in the spectral region from 450 to 775 nm was all-coupled into an alumina thin film, which functioned as a single-mode planar optical waveguide. The alumina thin-film waveguide used for this work had a thickness of 180 nm and was deposited on a glass substrate by the atomic layer deposition process. The protein submonolayer was formed on the alumina waveguide surface through electrostatic adsorption from an aqueous buffer solution at neutral pH. The optical properties of the surface-adsorbed cyt c were investigated for bulk protein concentrations ranging from 5 nM to 8200 nM in the aqueous buffer solution. For a protein surface density of 2.3 pmol/cm(2), the molar absorptivity measured at the charge transfer band was 335 M(-1) cm(-1), and for a surface density of 15 pmol/cm(2) was 720 M(-1) cm(-1), which is much closer to the value of cyt c dissolved in an aqueous neutral buffer (830 M(-1) cm(-1)). The modification of the protein molar absorptivity and its dependence on the surface density can most likely be attributed to conformational changes of the surface-adsorbed species.

SELECTION OF CITATIONS
SEARCH DETAIL
...