Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Gastrointest Endosc ; 74(3): 581-589.e1, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21601200

ABSTRACT

BACKGROUND: Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE: To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. DESIGN AND SETTING: Prospective, multicenter trial including 8 European sites. PATIENTS: This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. INTERVENTION: CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are ≥6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. MAIN OUTCOME MEASUREMENTS: CCE-2 sensitivity and specificity for detecting patients with polyps ≥6 mm and ≥10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. RESULTS: Per-patient CCE-2 sensitivity for polyps ≥6 mm and ≥10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. LIMITATIONS: Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. CONCLUSION: In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoid lesions, and it might be considered an adequate tool for colorectal imaging.


Subject(s)
Adenoma/diagnosis , Capsule Endoscopy , Colonic Polyps/diagnosis , Colonoscopy , Colorectal Neoplasms/diagnosis , Aged , Capsule Endoscopy/adverse effects , Colonic Polyps/pathology , Colonoscopy/adverse effects , Female , Humans , Male , Middle Aged , Prospective Studies , Sensitivity and Specificity
2.
Case Rep Gastroenterol ; 4(3): 416-420, 2010 Oct 05.
Article in English | MEDLINE | ID: mdl-21060711

ABSTRACT

Coeliac disease (CD) is an autoimmune disorder which leads to chronic inflammation of the gut. Furthermore, CD is associated with upper gastrointestinal malignancies, particularly lymphoma of the small intestine. Besides lymphoma, an increased frequency of associated small bowel carcinoma has been described. Here we report the case of a 70-year-old male suffering from CD who was treated with a gluten-free diet presenting with complaints of nausea, vomiting and weight loss of about 8 kg in two months. He underwent esophagogastroduodenoscopy, which identified distention of the stomach and duodenum and in the pars horizontalis a distinct obstruction was suggestive. However, histopathological examination showed a normal mucosal membrane. Additionally, a computed tomography scan of the abdomen was performed which showed an expanded stomach and duodenum up to the ligament of Treitz. During an explorative laparotomy a small tumor was palpated near the ligament of Treitz. Subsequently, a duodenal segment resection was performed. After surgery, the patient recovered well and left our hospital in good condition.

SELECTION OF CITATIONS
SEARCH DETAIL