Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Paediatr Child Health ; 42(11): 743-4, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17044907

ABSTRACT

Systemic embolism in childhood is rare but often disastrous. Most often the concomitant occurrence of more than one prothrombotic factor is responsible for the acute event. We report on a child in whom an intracardiac thrombus embolized into the descending aorta resulting in subtotal occlusion. Causative for thrombus formation was an idiopathic ventricular tachycardia and a heterozygous activated protein C resistance, both previously unknown. Immediate surgical thrombectomy was successful without sequelae. Antithrombotic and antiarrhythmispioproptylactic treatment was started afterwards. We suggest that in cases of longstanding or repeated tachycardia and in children after thromboembolic events diagnostic work-up for thrombophilia should be undertaken.


Subject(s)
Protein C Deficiency , Tachycardia, Ventricular/physiopathology , Thromboembolism/etiology , Child, Preschool , Female , Germany , Heterozygote , Humans
2.
Acta Paediatr ; 94(9): 1243-7, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16278992

ABSTRACT

AIM: An important differential diagnosis of seizures in childhood is the long QT syndrome. Childhood epilepsy occurs about 400 times more often than long QT syndrome. We had observed children with slight post-convulsive prolongation of QT time more often than the reported incidence of long QT syndrome. We therefore conducted a prospective study to define the characteristics of post-convulsive prolongation of QT time in children. METHODS: We investigated 30 consecutive infants and children (3 mo to 14 y) within 2 h after seizures. A follow-up ECG was obtained 1-9 d later. We also obtained ECGs from 30 healthy age- and gender-matched controls. We calculated the QT interval corrected for heart rate (QTc) by Bazett's formula in leads II, V5, V6, QT dispersion and the number of notched T waves. RESULTS: We found a QTc interval of more than 440 ms in one or more leads in the first ECG in seven of 30 infants and children compared to 1 of 30 in the follow-up ECG (p=0.0003) and two of 30 in the healthy controls (p=0.14). Average QTc was higher for all leads in the first ECG. This was statistically significant in leads II (414 vs 402 ms, p=0.008), V5 (416 vs 404 ms, p=0.002) and V6 (415 vs 399 ms, p=0.001). Compared to healthy controls, QT dispersion was slightly larger in the early post-convulsive ECG (36 vs 31 ms, p=0.03). Notched T waves occurred more frequently in the early compared to the late post-convulsive ECGs (p=0.009). CONCLUSION: Slight to moderate post-convulsive prolongation of the QT interval is not rare but transient in paediatric patients.


Subject(s)
Long QT Syndrome/physiopathology , Seizures/physiopathology , Adolescent , Case-Control Studies , Child , Child, Preschool , Electrocardiography , Heart Rate , Humans , Infant , Long QT Syndrome/diagnosis , Prospective Studies , Time Factors
3.
J Am Soc Echocardiogr ; 18(4): 362-6, 2005 Apr.
Article in English | MEDLINE | ID: mdl-15846165

ABSTRACT

Two-dimensional (2D) echocardiography is a user-dependent technique that poses some inherent problems to the beginner. The first problem for beginners is spatial orientation, especially the orientation of the scan plane in reference to the 3-dimensional (3D) geometry of the heart. The second problem for beginners is steering of the ultrasound probe. We have designed a simulator to teach these skills. On a computer screen a side-by-side presentation of a 3D virtual reality scene on the right side and a 2D echocardiographic view on the left side is given. The virtual scene consists of a 3D heart and an ultrasound probe with scan plane. The 2D echocardiographic image is calculated from 3D echocardiographic data sets that are registered with the heart model to achieve spatial and temporal congruency. The displayed 2D echocardiographic image is defined and controlled by the orientation of the virtual scan plane. To teach hand-eye coordination we equipped a dummy transducer with a 3D tracking system and placed it on a dummy torso. We have evaluated the usability of the simulator in an introductory course for final-year medical students. The simulator was graded realistic and easy to use. According to a subjective self-assessment by a standardized questionnaire the aforementioned skills were imparted effectively.


Subject(s)
Cardiology/education , Computer-Assisted Instruction , Echocardiography , Education, Medical, Undergraduate/methods , Adult , Female , Humans , Male , User-Computer Interface
SELECTION OF CITATIONS
SEARCH DETAIL
...