Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Skin Res Technol ; 28(4): 577-581, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35638406

ABSTRACT

BACKGROUND: The purpose of this pilot study was to provide information about the washout-dependent depletion of important skin components in the horny layer of the scalp. They were taken as markers for scalp drying effects of cosmetic cleansing products and were measured directly in vivo. METHOD: In vivo confocal Raman spectroscopy was used to measure the depletion of the total natural moisturizing factor (total NMF) and some of its components (urea and lactic acid) as well as a fraction of stratum corneum lipids, after repeated washing with a standard shampoo on the human scalp. RESULTS: The measurements showed a reduction in the amount of NMF and lipids of the stratum corneum caused by repeated shampooing. CONCLUSION: Confocal Raman spectroscopy is an innovative technology that can be used successfully in vivo on the hairy scalp. The loss of the most important skin components caused by hair washing can be quantified directly with this technology. The method is valuable to support the development cosmetic cleansing products, as it is suitable to directly compare the effects of different product candidates on the human scalp in a most realistic way.


Subject(s)
Cosmetics , Skin Abnormalities , Cosmetics/pharmacology , Hair , Humans , Lipids/analysis , Pilot Projects , Scalp , Skin , Spectrum Analysis, Raman/methods
2.
J Cosmet Dermatol ; 21(2): 689-697, 2022 Feb.
Article in English | MEDLINE | ID: mdl-33825333

ABSTRACT

BACKGROUND: The treatment of facial erythema and subjective symptoms of rosacea patients remains challenging in clinical practice. Cosmeceuticals, care components containing active ingredients such as phytochemicals, play a growing role in treatment plans. However, well-designed studies on their efficacy and limitations are widely missing. OBJECTIVE: A foam and a cream for rosacea patients were assessed based on objective and subjective methodology. The tolerability of skin and eyes was evaluated. METHODS: A randomized, double-blinded, split-face, and vehicle-controlled trial was conducted. At baseline and after four weeks of product use, dermatological and ophthalmological investigations were performed, employing image analysis of facial erythema, clinical assessments, and questionnaires. RESULTS: The patient cohort comprised 33 females with persistent facial erythema due to rosacea. No significant differences were found between the vehicle and the verum. According to the analysis of facial erythema, a "less pronounced" or "much less pronounced" appearance was seen in two thirds of patients comparing V1 to V0. Especially, the dryness of the skin improved by the use of the vehicle and the verum. Adverse subjective skin sensations decreased by 61.3% for the verum side and by 58.6% for the vehicle side. Subjective and objective analysis of ocular manifestation differed, with subjective manifestations reported more frequently, thus highlighting underdiagnosis of ocular rosacea. CONCLUSIONS: As no clear differences between the verum and the vehicle were found, an optimal skin care regime itself seems to have a superior effect in the relief of facial erythema and foremost of subjective symptoms, rather than certain active ingredients.


Subject(s)
Detergents , Rosacea , Detergents/adverse effects , Erythema/chemically induced , Female , Humans , Rosacea/drug therapy , Skin Cream , Treatment Outcome
3.
J Occup Med Toxicol ; 16(1): 25, 2021 Jul 05.
Article in English | MEDLINE | ID: mdl-34225747

ABSTRACT

BACKGROUND: Outdoor workers (OW) are highly exposed to solar ultraviolet radiation (UVR) and thus at increased risk for developing skin cancer. An essential part of an overall strategy to reduce workplace UVR-exposure to OW's skin is the usage of sunscreens. However, compliance with regular sunscreen usage seems to be low, as products are usually designed for recreational sun exposure and thus do not meet the requirements of physically active OW. To date, no standardized test procedures assess the suitability of sunscreens for professional use. The aim of this pilot study was to develop standardized methods of testing secondary performance attributes (PA) to represent real-life working conditions of outdoor work. METHODS: Ten sunscreen products, carefully selected after a detailed market survey of all relevant producers available on the German market, were evaluated regarding their suitability for professional outdoor work on 24 healthy volunteers in a newly designed test procedure. In addition to three standardized efficacy characteristics, i.e., sun protection factor, water-resistance, and UVA protection, we evaluated each PA involving parameters typically associated with outdoor workplaces. RESULTS: We developed standardized methods for objectifying the suitability of sunscreen products for professional outdoor work. The test procedures used are well feasible and appropriate for testing the PA because they represent practical working conditions in detail - although the degree of discriminability of single test methods varied. The claimed sun protection factor (SPF) of the products was confirmed; bio-stability of the SPF after physical activity was achieved in most cases. While most products hardly irritate the eyes and are quickly absorbed, the evaluation of the subjective skin feeling and non-slip grip is inconsistent. CONCLUSIONS: In this pilot study, for the first time secondary PA are defined and examined. Although further objectification of the PA assessment as well as the establishment of minimum standards should be sought, the new methods could already complement the so far mandatory labels and in this way provide a significant impetus for the current scientific and political focus on the improvement of occupational health in highly UVR-exposed OW.

4.
Skin Res Technol ; 27(6): 1092-1099, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34110051

ABSTRACT

BACKGROUND: Skin damage arising from pollutants in gaseous and particulate matter forms is mainly mediated by oxidative stress. The pollutants directly or indirectly generate free radicals on and in the skin, leading, for example, to MMP up-regulation and damage of collagen fibers. Antioxidants and chelators are used in anti-pollution cosmetics to reduce the harmful effects of free radical generation. MATERIALS AND METHODS: We investigated the efficacy of two antioxidants and one chelator in an anti-pollution cigarette smoke model. Free radical generation was measured directly after UV and cigarette smoke exposure ex vivo on pig skin (slaughterhouse waste), by use of Electron Spin Resonance (ESR). Effects of cigarette smoke were compared to those of Urban Dust (NIST-standard). ESR was also used to measure the copper chelation activity of the test products. Following cigarette smoke application in vivo, two markers of lipid peroxidation malondialdehyde (MDA), and squalene monohydroperoxide (SQOOH), were measured from swab solutions taken from the smoke-exposed skin sites. RESULTS: EDTA generated no effect and the non-chelator antioxidant Tocopherol only small antioxidant effects after exposed to cigarette smoke ex vivo as well as in vivo. Only the hydrophilic phenylethanoid H1 showed significant effects. A clear reduction of free radicals ex vivo and further a significant reduction of in vivo lipid peroxide formation was measured. CONCLUSION: The cigarette smoke model is an ideal method for in vivo assessment of anti-pollution efficacy of topical products with close relation to the real situation of subjects exposed to urban pollution. Further research is required to better understand the role of chelators in anti-pollution cosmetics.


Subject(s)
Antioxidants , Chelating Agents , Animals , Antioxidants/pharmacology , Electron Spin Resonance Spectroscopy , Humans , Smoke/adverse effects , Smoking , Swine
5.
Dermatol Ther (Heidelb) ; 11(3): 983-994, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33913104

ABSTRACT

INTRODUCTION: Antivirals and occlusive lip patches are key treatments for cold sores. Additional therapeutic options, and validated methods to evaluate these, are needed. METHODS: This exploratory, double-blind, single-center study aimed to evaluate a novel lip patch containing the antiviral aciclovir (ACV) using noninvasive methods for measuring cold sore-associated inflammation. Healthy subjects with ultraviolet radiation (UVR)-induced cold sores were randomized to 10 days' treatment with a lip patch containing ACV (N = 12) or without ACV (N = 13). Outcome measures included blood flux (field laser perfusion imaging, FLPI), skin temperature (thermography), and skin redness (high-resolution color photography, HRCP). RESULTS: Mean blood flux (in perfusion units) and skin temperature (in °C/pixel) were higher for cold sores versus intrasubject control regions. For ACV versus placebo patches, skin temperature was higher for ACV with total day 1-5 mean values of 2.6 versus 0.5 (p = 0.036) and day 1-10 mean values of 3.2 versus 0.8 (p = 0.049). Conversely, mean total episode blood flux values over days 1-5 were lower for ACV versus placebo patch (flux 2227 versus 2939, p = 0.340) and remained lower over days 1-10 (flux ACV 810 versus placebo 961, p = 0.404). HRCP failed to discriminate cold sores from control regions or between treatments. Subject-reported pain/soreness, itching, and burning were generally lower with ACV patch. CONCLUSIONS: FLPI reliably measures cold sore-related inflammation and thermography heat radiating from the skin. HRCP was of little value. TRIAL REGISTRATION: NCT01653509.

6.
Skin Res Technol ; 27(3): 404-413, 2021 May.
Article in English | MEDLINE | ID: mdl-33098353

ABSTRACT

BACKGROUND: In vivo confocal Raman spectroscopy (CRS) revealed a clear correlation of age and dermal water content, indicating increasing water content of the dermis with increasing age. This enhancement of water has been interpreted as an age-dependent depletion, of proteins, mainly of collagen. Chronical sun exposure is known to destroy the collagen network of the skin, which leads to the signs of photoaging as the formation of wrinkles. Noninvasive in vivo measuring techniques for photoaging are limited. Therefore, sensitive techniques to quantify even mild degrees of photoaging in a clinical setting are of high interest. We used CRS to measure the water content in human dermis in vivo, assuming that additionally to the increase of water content in intrinsic aging, photoaging would lead to further collagen depletion and an additional increase in water content of the dermis. MATERIALS AND METHODS: A panel of 24 female subjects of different age-groups and scores of photoaging was recruited. A ranking of high resolution dorsal forearm photographs was used to classify the degree of photoaging with high precision. After that, CRS water content and collagen measurements were performed in the photoexposed dorsal as well as the photoprotected volar dermis of the subjects. RESULTS: A positive correlation of water content in the dermis with age could be confirmed (r = .550). Further, a positive correlation between water content of dorsal dermis and photoaging ranks was observed (Pearson's r = .417). CONCLUSION: Assessment of water content in the dermis with confocal Raman spectroscopy was found to be a promising method to measure the degree of photoaging in human subjects in vivo.


Subject(s)
Skin Aging , Aging , Dermis , Female , Humans , Spectrum Analysis, Raman , Water
8.
J Med Food ; 23(2): 147-152, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32017646

ABSTRACT

The purpose of this randomized, placebo-controlled, triple-blind trial on 60 healthy female volunteers was to assess the cosmetic effects on skin quality of a food supplement containing special collagen peptides together with acerola extract, vitamin C, vitamin E, biotin, and zinc after an intake of 12 weeks (Elasten®, QUIRIS Healthcare, Germany). To reduce assessment bias maximally and increase the accuracy and objectivity of the outcomes, the trial design was triple blinded in a manner that neither the subjects nor the person administering the products nor the person who assessed the primary outcomes knew which subjects had received the test product and which had received the placebo. The expert grader assessing the confocal laser scanning microscopy images was additionally blinded regarding the time when the image was taken (on days 1 or 85). The objective, blinded, and validated image analyses using confocal laser scanning microscopy showed a significant improvement of the collagen structure of facial skin (primary endpoint) after intake of the test product, while no improvements were found after intake of the placebo. The proven positive nutritional effect on the collagen structure was fully consistent with positive subjective evaluations of relevant skin parameters such as elasticity, crinkliness/wrinkliness, and evenness in different body areas such as face, hands, décolleté, neck, backside, legs, and belly, all serving as secondary endpoints. The test product was found to be safe and very well tolerated. A cosmetically relevant improvement of the facial skin was demonstrated after administration of the collagen supplement.


Subject(s)
Collagen/pharmacology , Dietary Supplements , Skin Aging/drug effects , Skin/drug effects , Vitamins/pharmacology , Double-Blind Method , Female , Humans , Microscopy, Confocal , Middle Aged
9.
Skin Res Technol ; 26(3): 390-397, 2020 May.
Article in English | MEDLINE | ID: mdl-31820504

ABSTRACT

BACKGROUND/AIM: It was the aim to establish and validate in vivo confocal Raman spectroscopy for characterization of the lip barrier in conjunction with transepidermal water loss (TEWL) and skin capacitance assessments. For the first time in vivo, barrier-relevant components of the lip (derived, natural moisturizing factors (NMFs) and ceramides are described. METHODS: In 32 healthy volunteers, a dental tongue fixation device was inserted to prevent both voluntary and involuntary lip moisturization during measurements. Seventeen individual parameters relating to water, ceramide, and NMF content were assessed via Raman spectroscopy. Additionally, corneometry and TEWL were measured. To give a guidance for the required volunteer group size of future lip barrier studies for all test parameters, coefficients of variation (CV) were calculated and plots showing the required sample size for a given percentage treatment effect. RESULTS: Raman spectroscopy assessed parameters on the lower lip comprehensively characterized the state of the lip barrier. Parameter variability was sufficiently low to corroborate changes in most parameters using relatively small study populations. CONCLUSIONS: Lip skin is comparatively well hydrated. Biophysical measurement of the lip barrier function is a challenge, as unconscious licking of the lower lip has to be prevented. In vivo confocal Raman spectroscopy provides insightful parameters for the characterization of the lip barrier and sufficiently low inter-individual variability to assess relatively small parameter changes employing relatively few study subjects. Differences at the molecular level and at a high spatial resolution are detectable, and these insights might provide a breakthrough in the evaluation of lip barrier function and developing solutions for lip care.


Subject(s)
Lip/chemistry , Skin Absorption/physiology , Skin/chemistry , Spectrum Analysis, Raman/methods , Water Loss, Insensible/physiology , Adult , Ceramides/chemistry , Ceramides/metabolism , Epidermis/metabolism , Female , Humans , Lip/metabolism , Middle Aged , Skin/metabolism , Skin Physiological Phenomena
10.
Skin Res Technol ; 25(4): 578-586, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30770595

ABSTRACT

BACKGROUND/AIM: The scope of this study was to utilize confocal Raman spectroscopy in the evaluation of the degree of non-penetration into the viable skin layers of a paraffin and petrolatum-based product for use in the intimate areas of the skin. The formulation was purposely designed with properties to prevent undesirable skin penetration. METHODS: Product-The test product was a proprietary topical medical device comprising paraffinum liquidum, petrolatum, paraffin, and tocopheryl acetate. Volunteers-A total of 20 healthy volunteers were recruited onto the study-17 females and three males. Product Testing-Raman spectra were obtained at Baseline and 90 minutes after product application. Product Penetration-Skin penetration was calculated from Raman spectra taken at skin depths of -5, 0, 5, 10, 15, and 20 µm. RESULTS: Raman spectra of the investigated product could be clearly differentiated from the skin spectrum. The minimum measurable concentration of the test product was determined at a detection level of 0.5%. In this study, the test product did not penetrate down to skin depths of 10 to 20 µm. CONCLUSIONS: Within the precision range of the test method, the investigated product did not penetrate into the compact part of the stratum corneum. The study revealed Raman spectroscopy to be suitable to detect not only penetration but also non-penetration of substances into human skin.


Subject(s)
Mineral Oil/administration & dosage , Skin Absorption/physiology , Skin/metabolism , Spectrum Analysis, Raman/methods , Spectrum Analysis/instrumentation , Administration, Topical , Adult , Epidermis/metabolism , Female , Humans , Male , Middle Aged , Mineral Oil/metabolism
11.
Curr Probl Dermatol ; 54: 19-25, 2018.
Article in English | MEDLINE | ID: mdl-30130769

ABSTRACT

The acidic nature of the skin surface was recognised more than a century ago and has been measured since 1928. Several non-invasive methods for measuring skin surface pH have been developed ever since and have contributed to our understanding of healthy and diseased skin. This chapter summarises the endogenous physiological, exogenous and environmental factors that influence skin surface pH and its measurement as well as the different measurement methods for skin surface pH, with specific emphasis on the classic planar glass electrode method. Also, practical guidance for measurement of skin surface pH using the planar glass electrode method is provided. Adherence to practical skin surface pH measurement (method) guidelines with due consideration and practicable control of all factors that may affect skin surface pH will ensure credible pH measurement results in our continuous pursuit of understanding especially diseased skin.


Subject(s)
Skin/chemistry , Calibration , Electrodes , Equipment Design , Glass , Humans , Hydrogen-Ion Concentration , Skin Diseases/metabolism
12.
Eur J Dent ; 12(3): 329-333, 2018.
Article in English | MEDLINE | ID: mdl-30147394

ABSTRACT

OBJECTIVE: The objective of this randomized clinical study was to assess the onset time of the whitening effect of a combined use of a nonabrasive, activator-containing toothpaste and a light emitting diode (LED) device, compared to that of the toothpaste alone. MATERIALS AND METHODS: A nonabrasive, activator-containing toothpaste was used twice daily alone or combined with an LED device for 15 days. The onset of the tooth whitening effect was evaluated through tooth color (a* b*, CIELAB) and tooth whiteness (WIO) by image analysis of standardized images. Local tolerance was assessed at days 1, 8, and 15. RESULTS: On day 8, a significant (P = 0.003) tooth whitening effect compared to day 1 was observed with the toothpaste and the LED device, sustaining until the end of the study. Whitening using the toothpaste alone was significant compared to day 1 after 15 days, only. One subject reported mild redness, itching, and burning on day 1 on the gum of the lower jaw that was possibly related to with the toothpaste. The subject withdrew from the study. No adverse event was reported in the group using the LED device. CONCLUSION: Both tooth whitening methods had a significant whitening effect after 15 days of use. However, the onset of whitening was significantly faster when using the nonabrasive, activator-containing toothpaste combined with an LED device. The toothpaste and LED device were both safe.

13.
J Dermatolog Treat ; 28(3): 251-257, 2017 May.
Article in English | MEDLINE | ID: mdl-27545858

ABSTRACT

PURPOSE: Two studies were conducted with a new topical panthenol-containing emollient (NTP-CE) to investigate the skin-moisturizing effect in healthy adults and tolerability in healthy infants. METHODS: In Study 1 (N = 44), a single skin application of NTP-CE was performed followed by a 4-week twice-daily application. Skin hydration and stratum corneum (SC) water content change (using Raman spectroscopy) were measured. In the 4-week Study 2 (N = 65, aged 3-25 months), NTP-CE tolerability was assessed using a 5-point scoring system; skin hydration was determined in a subset (N = 21). RESULTS: In Study 1, mean AUC0 - 24 h for skin capacitance change from baseline was 302.03 i.u. with NTP-CE and -15.90 i.u. in control areas (p < .001). With NTP-CE (at 4 h), the water content within the upper SC part was reduced (-45.10 vs. -13.39 g/cm2, p = .013) and the water gradient increased (0.51 vs. 0.11 g/cm4, p = .036), indicating relocation of water into deeper layers. In Study 2, there was no statistically significant change from baseline in mean cutaneous tolerability scores. At days 7, 14, and 28, skin hydration had increased by 42%, 54%, and 49%, respectively (all p < .001). CONCLUSIONS: Single and prolonged NTP-CE usage is associated with sustained and deep skin moisturization. NTP-CE is well tolerated by healthy infants.


Subject(s)
Emollients/pharmacology , Pantothenic Acid/chemistry , Skin/drug effects , Administration, Topical , Adolescent , Adult , Area Under Curve , Emollients/chemistry , Female , Humans , Infant , Male , Middle Aged , ROC Curve , Skin/chemistry , Skin/metabolism , Spectrum Analysis, Raman , Water/chemistry , Water/metabolism , Young Adult
14.
J Dermatolog Treat ; 28(2): 173-180, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27425824

ABSTRACT

PURPOSE: Two randomized, intra-individual comparison studies were performed in healthy subjects to evaluate the skin moisturization and barrier restoration potential of a new topical panthenol-containing emollient (NTP-CE) (Study 1), and its effect on skin microflora (Study 2). METHODS: In Study 1 (N = 23), two skin areas, one challenged with 0.5% sodium dodecyl sulfate (SDS) solution and one unchallenged, were treated with NTP-CE for 3 weeks. Transepidermal water loss (TEWL), skin hydration, and intercellular lipid lamellae (ICLL) organization were measured at regular intervals during the study. In Study 2 (N = 20), quantitative bacterial cultures were obtained over 6 h from a skin area undergoing wash stress with 10% SDS with subsequent single application of NTP-CE. RESULTS: In Study 1, mean AUC for TEWL reduction from baseline was more pronounced with NTP-CE compared with control (-168.36 vs. -123.38 g/m2/h, p = 0.023). NTP-CE use was also associated with statistically significant improvements in stratum corneum hydration and an increase in mean ICLL length from baseline (day 22: 120.61 vs. 35.85 nm/1000 nm2, p < 0.001). In Study 2, NTP-CE use had no negative impact on bacterial viability. CONCLUSIONS: NTP-CE use has favorable and lasting effects on barrier function and repair as well as skin hydration without negatively influencing bacterial viability.


Subject(s)
Emollients/administration & dosage , Pantothenic Acid/analogs & derivatives , Skin/microbiology , Water Loss, Insensible/drug effects , Administration, Topical , Adult , Body Water/metabolism , Emollients/pharmacology , Epidermis/metabolism , Female , Humans , Lipid Metabolism/drug effects , Male , Middle Aged , Pantothenic Acid/administration & dosage , Pantothenic Acid/pharmacology , Skin/metabolism , Sodium Dodecyl Sulfate , Young Adult
15.
Rev Recent Clin Trials ; 8(1): 29-35, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23259459

ABSTRACT

Manufacturers of consumer products consistently seek to improve marketed products in terms of both safety and efficacy. The desire for continued improvement is seen even in well-established products such as catamenial products which have existed in some form for thousands of years. A recent innovation in the design of menstrual pads is the addition of a surface finish of emollient for the purpose of increasing comfort during wear. The present paper presents different evaluations of such an emollient-treated menstrual pad with a novel absorbent core. These investigations demonstrated product tolerability, defined the optimal formulation and concentration of the emollient-containing finish, and demonstrated successful transfer of the emollient to the relevant skin surface. In addition, enhancement of skin moisturization, associated with exposure to the emollient-treated pad, was demonstrated by several technologies: assessment of skin moisturization by Corneometer®, skin friction testing, and skin capacitance.


Subject(s)
Emollients/administration & dosage , Menstrual Hygiene Products , Skin Care/methods , Equipment Design , Female , Humans , Patch Tests , Randomized Controlled Trials as Topic
16.
Skin Res Technol ; 19(1): e366-74, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22694144

ABSTRACT

BACKGROUND: Chronic wounds require frequent dressing changes. Adhesive dressings used for this indication can be damaging to the stratum corneum, particularly in the elderly where the skin tends to be thinner. Understanding the level of damage caused by dressing removal can aid dressing selection. METHODS: This study used a novel methodology that applied a stain to the skin and measured the intensity of that stain after repeated application and removal of a series of different adhesive types. Additionally, a traditional method of measuring skin barrier damage (transepidermal water loss) was also undertaken and compared with the staining methodology. RESULTS: The staining methodology and measurement of transepidermal water loss differentiated the adhesive dressings, showing that silicone adhesives caused least trauma to the skin. CONCLUSION: The staining methodology was shown to be as effective as transepidermal water loss in detecting damage to the stratum corneum and was shown to detect disruption of the barrier earlier than the traditional technique.


Subject(s)
Bandages/adverse effects , Colorimetry/methods , Epidermis/injuries , Epidermis/pathology , Skin Diseases/pathology , Surgical Tape/adverse effects , Adult , Aged , Blister/etiology , Blister/pathology , Body Water/metabolism , Edema/etiology , Edema/pathology , Epidermis/metabolism , Erythema/etiology , Erythema/pathology , Female , Humans , Male , Middle Aged , Silicon/adverse effects , Skin Diseases/etiology , Staining and Labeling/methods , Water Loss, Insensible/physiology
17.
Quintessence Int ; 43(8): 709-18, 2012 Sep.
Article in English | MEDLINE | ID: mdl-23034424

ABSTRACT

OBJECTIVE: The short-term and overnight effect of three treatment regimens on oral halitosis were investigated: toothbrushing with a reference toothpaste, toothbrushing with reference toothpaste and tongue cleaning, and toothbrushing and tongue cleaning with a tooth-and-tongue gel. METHOD AND MATERIALS: Fifty-four subjects meeting the inclusion criteria for bad breath were enrolled in the study. All subjects received each of the three treatment regimens in a balanced design. Efficacy was assessed by organoleptic ratings and volatile sulfur compound (VSC) measurements 5 and 60 minutes after first application and overnight after 7 days of repeated use. RESULTS: The combination of toothbrushing and tongue cleaning with tooth-and-tongue gel provided the best results in terms of organoleptic ratings and VSC measurements at all time points compared to the other treatment regimens. CONCLUSION: The use of tooth and tongue gel for both toothbrushing and tongue cleaning showed a positive short-term and overnight effects after 7 days of use. This treatment regimen is a promising approach to control halitosis.


Subject(s)
Dental Devices, Home Care , Dentifrices/therapeutic use , Halitosis/prevention & control , Sulfur Compounds/analysis , Tongue , Adolescent , Adult , Aged , Amines/therapeutic use , Cross-Over Studies , Drug Combinations , Female , Gels , Humans , Male , Middle Aged , Mouthwashes/therapeutic use , Statistics, Nonparametric , Surveys and Questionnaires , Tin Fluorides/therapeutic use , Tongue/chemistry , Tongue/microbiology , Toothbrushing , Young Adult
18.
Cutan Ocul Toxicol ; 31(3): 198-203, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22141375

ABSTRACT

CONTEXT: Apertured polyethylene films (AF) have been used as a surface for sanitary pads for decades because they are compatible with the skin and keep the pad surface drier. A modified film (AF-plus) with improved fluid handling and a smoother, suppler texture has been developed. We hypothesized that these changes would improve both performance and skin compatibility. However, distinguishing the skin effects of materials that are inherently mild is a challenge. OBJECTIVES: (i) To compare the skin irritation potential of pads with AF-plus modified film relative to the standard AF film and (ii) to assess the potential for the AF-plus film to induce delayed contact hypersensitivity. MATERIALS AND METHODS: Pads bearing the AF-plus film were compared to pads with the standard AF film in a behind-the-knee (BTK) test, which assesses the combination of chemical irritation and frictional effects of materials applied to the popliteal fossa under a semi-occlusive bandage. Erythema on the skin surface was scored with the naked eye and subsurface tissue erythema was visualized and scored using cross-polarized illumination. Skin dryness was scored with the naked eye only. One-sided statistical evaluations were performed to test the hypothesis of AF-plus film superiority. The potential of the AF-plus film to induce delayed contact hypersensitivity was assessed by a human repeat insult patch test (HRIPT). RESULTS: Pads with the AF-plus surface were significantly milder to skin in the BTK test, producing lower levels of both surface and subsurface tissue erythema. Moreover, subjects with preexisting erythema on the skin surface at study start developed comparatively less erythema over the course of the study overall with the AF-plus pad compared to the AF pad. No significant difference in skin dryness was observed between product groups. The AF-plus pad showed no evidence of inducing delayed contact hypersensitivity. CONCLUSIONS: The AF-plus pad was superior to the AF pad in terms of skin mildness as discerned by objectively scored surface and subsurface tissue erythema. In subjects with preexisting erythema, the AF-plus pad appeared to contribute less to the further development of inflammation under the test conditions. Given the compositional similarities in the two films, the results could point to more limited contribution of the AF-plus film to skin friction, one of the factors simulated by the BTK test protocol.


Subject(s)
Equipment Design , Menstrual Hygiene Products/adverse effects , Adult , Double-Blind Method , Erythema/chemically induced , Female , Humans , Hypersensitivity, Delayed , Surface Properties
20.
Contact Dermatitis ; 62(3): 157-64, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20565502

ABSTRACT

BACKGROUND: Development of cosmetic products and household detergents necessitates comparative study designs to assess the skin tolerance of products. In initial tests, the epicutaneous patch test for irritation is widely used. OBJECTIVES: This study was conducted to develop a protocol that would facilitate a comparison of results obtained when tests are conducted by different laboratories. METHODS: 'In-house' and standardized patch test protocols were used to assess irritation potentials of surfactant-based products in intra- and interlaboratory studies using defined surfactant samples. RESULTS: The various in-house protocols tested did not consistently produce equivalent results. In order to develop a study design that yields comparable results, various factors were identified and adjusted. The standardized study protocol includes occlusive application of 70 microl of the test substance to the back of 30 subjects, defined reading times and schemes, assessments based mainly on erythema, and inclusion of sodium laureth sulfate and sodium dodecyl sulfate as positive controls as well as water as a negative control. CONCLUSIONS: Use of the standardized protocol and training of assessors improved the reliability and consistency of results whereby the irritation potentials of the references and test samples were ranked similarly by the laboratories.


Subject(s)
Cosmetics/adverse effects , Patch Tests/methods , Patch Tests/standards , Skin Irritancy Tests/methods , Skin Irritancy Tests/standards , Surface-Active Agents/adverse effects , Adult , Female , Humans , Irritants/adverse effects , Laboratories , Male , Middle Aged , Skin/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL
...