Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 11(1): 16179, 2021 08 10.
Article in English | MEDLINE | ID: mdl-34376748

ABSTRACT

Over almost five decades of development and improvement, Magnetic Resonance Imaging (MRI) has become a rich and powerful, non-invasive technique in medical imaging, yet not reaching its physical limits. Technical and physiological restrictions constrain physically feasible developments. A common solution to improve imaging speed and resolution is to use higher field strengths, which also has subtle and potentially harmful implications. However, patient safety is to be considered utterly important at all stages of research and clinical routine. Here we show that dynamic metamaterials are a promising solution to expand the potential of MRI and to overcome some limitations. A thin, smart, non-linear metamaterial is presented that enhances the imaging performance and increases the signal-to-noise ratio in 3T MRI significantly (up to eightfold), whilst the transmit field is not affected due to self-detuning and, thus, patient safety is also assured. This self-detuning works without introducing any additional overhead related to MRI-compatible electronic control components or active (de-)tuning mechanisms. The design paradigm, simulation results, on-bench characterization, and MRI experiments using homogeneous and structural phantoms are described. The suggested single-layer metasurface paves the way for conformal and patient-specific manufacturing, which was not possible before due to typically bulky and rigid metamaterial structures.

2.
Sci Rep ; 9(1): 3034, 2019 02 28.
Article in English | MEDLINE | ID: mdl-30816312

ABSTRACT

Robustness against data inconsistencies, imaging artifacts and acquisition speed are crucial factors limiting the possible range of applications for magnetic resonance imaging (MRI). Therefore, we report a novel calibrationless parallel imaging technique which simultaneously estimates coil profiles and image content in a relaxed forward model. Our method is robust against a wide class of data inconsistencies, minimizes imaging artifacts and is comparably fast, combining important advantages of many conceptually different state-of-the-art parallel imaging approaches. Depending on the experimental setting, data can be undersampled well below the Nyquist limit. Here, even high acceleration factors yield excellent imaging results while being robust to noise and the occurrence of phase singularities in the image domain, as we show on different data. Moreover, our method successfully reconstructs acquisitions with insufficient field-of-view. We further compare our approach to ESPIRiT and SAKE using spin-echo and gradient echo MRI data from the human head and knee. In addition, we show its applicability to non-Cartesian imaging on radial FLASH cardiac MRI data. Using theoretical considerations, we show that ENLIVE can be related to a low-rank formulation of blind multi-channel deconvolution, explaining why it inherently promotes low-rank solutions.


Subject(s)
Image Processing, Computer-Assisted/methods , Artifacts , Calibration , Head/physiology , Humans , Knee/physiology , Magnetic Resonance Imaging/methods
3.
Magn Reson Med ; 79(4): 2057-2066, 2018 04.
Article in English | MEDLINE | ID: mdl-28840612

ABSTRACT

PURPOSE: The development of a calibrationless parallel imaging method for accelerated simultaneous multi-slice (SMS) MRI based on Regularized Nonlinear Inversion (NLINV), evaluated using Cartesian and radial fast low-angle shot (FLASH). THEORY AND METHODS: NLINV is a parallel imaging method that jointly estimates image content and coil sensitivities using a Newton-type method with regularization. Here, NLINV is extended to SMS-NLINV for reconstruction and separation of all simultaneously acquired slices. The performance of the extended method is evaluated for different sampling schemes using phantom and in vivo experiments based on Cartesian and radial SMS-FLASH sequences. RESULTS: The basic algorithm was validated in Cartesian experiments by comparison with ESPIRiT. For Cartesian and radial sampling, improved results are demonstrated compared to single-slice experiments, and it is further shown that sampling schemes using complementary samples outperform schemes with the same samples in each partition. CONCLUSION: The extension of the NLINV algorithm for SMS data was implemented and successfully demonstrated in combination with a Cartesian and radial SMS-FLASH sequence. Magn Reson Med 79:2057-2066, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Subject(s)
Heart/diagnostic imaging , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging , Algorithms , Calibration , Diastole , Fourier Analysis , Humans , Models, Statistical , Nonlinear Dynamics , Phantoms, Imaging
4.
J Appl Crystallogr ; 48(Pt 6): 1818-1826, 2015 Dec 01.
Article in English | MEDLINE | ID: mdl-26664342

ABSTRACT

Simultaneous scanning Bragg contrast and small-angle ptychographic imaging of a single solar cell nanowire are demonstrated, using a nanofocused hard X-ray beam and two detectors. The 2.5 µm-long nanowire consists of a single-crystal InP core of 190 nm diameter, coated with amorphous SiO2 and polycrystalline indium tin oxide. The nanowire was selected and aligned in real space using the small-angle scattering of the 140 × 210 nm X-ray beam. The orientation of the nanowire, as observed in small-angle scattering, was used to find the correct rotation for the Bragg condition. After alignment in real space and rotation, high-resolution (50 nm step) raster scans were performed to simultaneously measure the distribution of small-angle scattering and Bragg diffraction in the nanowire. Ptychographic reconstruction of the coherent small-angle scattering was used to achieve sub-beam spatial resolution. The small-angle scattering images, which are sensitive to the shape and the electron density of all parts of the nanowire, showed a homogeneous profile along the nanowire axis except at the thicker head region. In contrast, the scanning Bragg diffraction microscopy, which probes only the single-crystal InP core, revealed bending and crystalline inhomogeneity. Both systematic and non-systematic real-space movement of the nanowire were observed as it was rotated, which would have been difficult to reveal only from the Bragg scattering. These results demonstrate the advantages of simultaneously collecting and analyzing the small-angle scattering in Bragg diffraction experiments.

5.
J Synchrotron Radiat ; 22(4): 867-78, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26134789

ABSTRACT

A compound optical system for coherent focusing and imaging at the nanoscale is reported, realised by high-gain fixed-curvature elliptical mirrors in combination with X-ray waveguide optics or different cleaning apertures. The key optical concepts are illustrated, as implemented at the Göttingen Instrument for Nano-Imaging with X-rays (GINIX), installed at the P10 coherence beamline of the PETRA III storage ring at DESY, Hamburg, and examples for typical applications in biological imaging are given. Characteristic beam configurations with the recently achieved values are also described, meeting the different requirements of the applications, such as spot size, coherence or bandwidth. The emphasis of this work is on the different beam shaping, filtering and characterization methods.

6.
J Appl Crystallogr ; 48(Pt 1): 116-124, 2015 Feb 01.
Article in English | MEDLINE | ID: mdl-26089748

ABSTRACT

This article describes holographic imaging experiments using a hard X-ray multilayer zone plate (MZP) with an outermost zone width of 10 nm at a photon energy of 18 keV. An order-sorting aperture (OSA) is omitted and emulated during data analysis by a 'software OSA'. Scanning transmission X-ray microscopy usually carried out in the focal plane is generalized to the holographic regime. The MZP focus is characterized by a three-plane phase-retrieval algorithm to an FWHM of 10 nm.

7.
Nano Lett ; 14(12): 7071-6, 2014 Dec 10.
Article in English | MEDLINE | ID: mdl-25419623

ABSTRACT

Submicron sized sensors could allow higher resolution in X-ray imaging and diffraction measurements, which are ubiquitous for materials science and medicine. We present electrical measurements of a single 100 nm diameter InP nanowire transistor exposed to hard X-rays. The X-ray induced conductance is over 5 orders of magnitude larger than expected from reported data for X-ray absorption and carrier lifetimes. Time-resolved measurements show very long characteristic lifetimes on the order of seconds, tentatively attributed to long-lived traps, which give a strong amplification effect. As a proof of concept, we use the nanowire to directly image an X-ray nanofocus with submicron resolution.

8.
J Synchrotron Radiat ; 21(Pt 5): 1167-74, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25178008

ABSTRACT

Coherent (X-ray) diffractive imaging (CDI) is an increasingly popular form of X-ray microscopy, mainly due to its potential to produce high-resolution images and the lack of an objective lens between the sample and its corresponding imaging detector. One challenge, however, is that very high dynamic range diffraction data must be collected to produce both quantitative and high-resolution images. In this work, hard X-ray ptychographic coherent diffractive imaging has been performed at the P10 beamline of the PETRA III synchrotron to demonstrate the potential of a very wide dynamic range imaging X-ray detector (the Mixed-Mode Pixel Array Detector, or MM-PAD). The detector is capable of single photon detection, detecting fluxes exceeding 1 × 10(8) 8-keV photons pixel(-1) s(-1), and framing at 1 kHz. A ptychographic reconstruction was performed using a peak focal intensity on the order of 1 × 10(10) photons µm(-2) s(-1) within an area of approximately 325 nm × 603 nm. This was done without need of a beam stop and with a very modest attenuation, while `still' images of the empty beam far-field intensity were recorded without any attenuation. The treatment of the detector frames and CDI methodology for reconstruction of non-sensitive detector regions, partially also extending the active detector area, are described.


Subject(s)
Image Enhancement/methods , Optical Imaging/methods , X-Ray Diffraction/methods , Image Enhancement/instrumentation , Optical Imaging/instrumentation , Synchrotrons , X-Ray Diffraction/instrumentation
9.
J Synchrotron Radiat ; 20(Pt 3): 490-7, 2013 May.
Article in English | MEDLINE | ID: mdl-23592629

ABSTRACT

In the past decade Kirkpatrick-Baez (KB) mirrors have been established as powerful focusing systems in hard X-ray microscopy applications. Here a ptychographic characterization of the KB focus in the dedicated nano-imaging setup GINIX (Göttingen Instrument for Nano-Imaging with X-rays) at the P10 coherence beamline of the PETRA III synchrotron at HASLYLAB/DESY, Germany, is reported. More specifically, it is shown how aberrations in the KB beam, caused by imperfections in the height profile of the focusing mirrors, can be eliminated using a pinhole as a spatial filter near the focal plane. A combination of different pinhole sizes and illumination conditions of the KB setup makes the prepared optical setup well suited not only for high-resolution ptychographic coherent X-ray diffractive imaging but also for moderate-resolution/large-field-of-view propagation imaging in the divergent KB beam.


Subject(s)
Lenses , Microscopy/instrumentation , Microscopy/methods , Radiographic Image Enhancement/instrumentation , Radiographic Image Enhancement/methods , Computer Simulation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Models, Theoretical
SELECTION OF CITATIONS
SEARCH DETAIL
...