J Nucl Med ; 26(7): 718-21, 1985 Jul.
Article in English | MEDLINE | ID: mdl-4009282

ABSTRACT

Thirty-three patients with painful joint prostheses and a suspicion of infection were imaged with [111In]chloride. A final diagnosis was established by culture in 19. Of these, 12 were categorized as true positives and three as true negatives. There were two false-positive studies, occurring in patients with knee prostheses. In both, the culture was obtained by aspiration. Two false negatives were in patients with hip prostheses, one of whom had been on long-term antibiotic suppressive therapy. The sensitivity was 86%, specificity 60%, and accuracy 79%. Seventeen of the proven cases had bone imaging prior to [111In]chloride imaging. All 17 static images were positive and were not helpful in differentiating loosening from infection. Using increased uptake on the blood-pool image as a criteria for infection, the sensitivity was 89%, but the specificity was 0. Adding flow studies made little difference in interpreting the blood-pool images. This study shows that [111In]chloride accurate in evaluating infection in prosthesis than bone imaging.


Subject(s)
Indium , Joint Prosthesis/adverse effects , Radioisotopes , Surgical Wound Infection/diagnostic imaging , Technetium Tc 99m Medronate/analogs & derivatives , Adult , Bone and Bones/diagnostic imaging , Diphosphonates , False Positive Reactions , Hip Prosthesis/adverse effects , Humans , Knee Prosthesis/adverse effects , Radionuclide Imaging , Technetium
2.
J Nucl Med ; 26(3): 225-9, 1985 Mar.
Article in English | MEDLINE | ID: mdl-3882904

ABSTRACT

Sixty-eight patients with clinically suspected chronic osteomyelitis were studied with [111In]chloride. Fifty-four images were categorized as true positive; seven were categorized as true negative. There were four false-positive studies, two of which were associated with healing cancellous bone grafts. There were three false-negative studies in patients previously treated with long-term antibiotic therapy. Images in eight noninfected healing fractures 3 to 8 mo old were normal. Three patients with infected total hip prostheses had positive images. Two patients with loose prostheses had negative images. This study shows that [111In]chloride imaging is an accurate way to localize chronic osteomyelitis and may overcome some of the disadvantages of [67Ga]citrate such as localization in noninfected healing fractures and in some loose [67Ga]citrate such as localization in noninfected healing fractures and in some loose prostheses.


Subject(s)
Indium , Osteomyelitis/diagnostic imaging , Radioisotopes , Adolescent , Adult , Aged , Bone Transplantation , Chronic Disease , False Negative Reactions , False Positive Reactions , Femur/diagnostic imaging , Hip Prosthesis/adverse effects , Humans , Middle Aged , Radionuclide Imaging , Tibia/diagnostic imaging