Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Patient Prefer Adherence ; 17: 1923-1933, 2023.
Article in English | MEDLINE | ID: mdl-37581193

ABSTRACT

Background: The RebiSmart® electromechanical autoinjector supports people living with relapsing multiple sclerosis (MS) with their adherence to treatment with subcutaneous interferon beta-1a (sc IFN ß-1a; Rebif®), a well-established and effective therapy. We report on the validation of the next-generation device, RebiSmart 3.0, tailored to meet patients' changing needs. Methods: To conclude a series of formative usability studies, a final formative study of an updated prototype version of the RebiSmart electromechanical autoinjector was conducted to identify the device's strengths, potential device-related use errors, opportunities for improvement, and to inform device safety. The findings were incorporated into the next-generation device, RebiSmart 3.0, which was then evaluated in a summative usability study involving 45 participants. The study consisted of evaluation activities - use scenarios and knowledge tasks - designed to validate mitigations to reduce the risks of not successfully completing critical tasks for successful administration of medication. During each evaluation activity, observations (including use errors, instances of moderator assistance, close calls, and difficulties) were recorded, focusing on the potential for serious harm arising from not completing critical tasks. Participants then provided their subjective assessment of RebiSmart 3.0 as part of a user needs survey that assessed device usability and design. Results: Regarding critical tasks, main findings were failure to inspect/dispose of the cartridge and not washing hands or disinfecting the injection site. These issues could be readily overcome by modifying future training. In the subjective assessment, 43 out of 45 participants considered the updated device safe to use as-is. In the user needs survey, overall, the participants rated the device positively. Conclusion: Findings validate the safety of use of the next-generation device, RebiSmart 3.0, through a comprehensive evaluation of use scenarios and knowledge tasks by the study participants, who provided positive ratings of the device in the user needs survey.

2.
Biochem Mol Biol Educ ; 34(6): 444-6, 2006 Nov.
Article in English | MEDLINE | ID: mdl-21638743

ABSTRACT

This article describes an undergraduate biochemistry laboratory investigating the ubiquitin-proteasome pathway in yeast. In this exercise, the enzyme ß-galactosidase (ß-gal) is expressed in yeast under the control of a stress response promoter. Following exposure to heat stress to induce ß-gal expression, cycloheximide is added to halt translation, and ß-gal degradation is monitored by measuring enzyme activity as a function of time. Students observe that an N-Ile-ß-gal variant with an N-terminal isoleucine has a significantly lower stability than wild-type ß-gal, whose N-terminal residue is methionine. This strong dependence of protein stability on the N-terminal residue is known as the "N-end rule." To corroborate the enzyme activity assay results, students perform denaturing protein electrophoresis and immunoblotting of lysates, observing that the time-dependent loss of enzyme activity is coincident with the disappearance of the ß-gal protein.

SELECTION OF CITATIONS
SEARCH DETAIL
...