Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Haematol ; 195(5): 669-680, 2021 12.
Article in English | MEDLINE | ID: mdl-34105142

ABSTRACT

Lymphocyte-variant hypereosinophilic syndrome (L-HES) is a rare disease driven by immunophenotypically aberrant T cells producing eosinophilopoetic cytokines such as interleukin-5 (IL-5). Treatment is challenging because L-HES is relatively steroid resistant and not amenable to tyrosine kinase inhibitors. We searched the literature for clinical trials and observational studies, including case reports, of patients treated for L-HES. In all, 25 studies were selected; two were randomised controlled trials of IL-5 blockade, which included some patients with L-HES, and the rest were observational studies. Corticosteroids are often used as first-line therapy, but patients with L-HES have lower response rates than other types of HES. Treatments that reduce symptoms and steroid dependence in some patients include interferon-alpha (IFN-α), anti-IL-5 monoclonal antibodies, cyclosporine and mycophenolate. These drugs target T-cell activation and proliferation, or IL-5 directly. Although effective, IFN-α and cyclosporine were commonly reported to cause side-effects resulting in discontinuation. Alemtuzumab can induce remissions, but these are generally short lived. The anti-IL-5 monoclonal antibodies mepolizumab and benralizumab are effective and well tolerated, but with a high rate of relapse once withdrawn. Hydroxyurea, methotrexate, imatinib were unsuccessful in most patients studied. More prospective clinical trials are needed for patients with L-HES.


Subject(s)
Hypereosinophilic Syndrome/diagnosis , Hypereosinophilic Syndrome/drug therapy , Adrenal Cortex Hormones/therapeutic use , Alemtuzumab/therapeutic use , Antibodies, Monoclonal/therapeutic use , Cyclosporine/therapeutic use , Humans , Hydroxyurea/therapeutic use , Hypereosinophilic Syndrome/immunology , Imatinib Mesylate/therapeutic use , Immunologic Factors/therapeutic use , Immunosuppressive Agents/therapeutic use , Interferon-alpha/therapeutic use , Interleukin-5/antagonists & inhibitors , Lymphocyte Activation/drug effects , Lymphocytes/drug effects , Lymphocytes/immunology
2.
J Clin Endocrinol Metab ; 95(7): 3360-7, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20444913

ABSTRACT

BACKGROUND/RATIONALE: Autoantibodies to islet antigen-2 (IA-2A) and glutamic acid decarboxylase (GADA) are markers for diagnosis, screening, and measuring outcomes in National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) consortia studies. A harmonization program was established to increase comparability of results within and among these studies. METHODS: Large volumes of six working calibrators were prepared from pooled sera with GADA 4.8-493 World Health Organization (WHO) units/ml and IA-2A 2-235 WHO units/ml. Harmonized assay protocols for IA-2A and GADA using (35)S-methionine-labelled in vitro transcribed and translated antigens were developed based on methods in use in three NIDDK laboratories. Antibody thresholds were defined using sera from patients with recent onset type 1 diabetes and healthy controls. To evaluate the impact of the harmonized assay protocol on concordance of IA-2A and GADA results, two laboratories retested stored TEDDY study sera using the harmonized assays. RESULTS: The harmonized assays gave comparable but not identical results in the three laboratories. For IA-2A, using a common threshold of 5 DK units/ml, 549 of 550 control and patient samples were concordantly scored as positive or negative, specificity was greater than 99% with sensitivity 64% in all laboratories. For GADA, using thresholds equivalent to the 97th percentile of 974 control samples in each laboratory, 1051 (97.9%) of 1074 samples were concordant. On the retested TEDDY samples, discordance decreased from 4 to 1.8% for IA-2A (n = 604 samples; P = 0.02) and from 15.4 to 2.7% for GADA (n = 515 samples; P < 0.0001). CONCLUSION: Harmonization of GADA and IA-2A is feasible using large volume working calibrators and common protocols and is an effective approach to ensure consistency in autoantibody measurements.


Subject(s)
Autoantibodies/immunology , Glutamate Decarboxylase/immunology , Radioligand Assay/methods , Receptor-Like Protein Tyrosine Phosphatases, Class 8/immunology , Academies and Institutes , Adolescent , Adult , Humans , Reference Values , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...