1.
Magn Reson Imaging ; 101: 35-39, 2023 09.
Article in English | MEDLINE | ID: mdl-37004795

ABSTRACT

OBJECTIVES: Previously in rodent and swine models, we have shown that external low intensity focused ultrasound (liFUS) can be used to modulate pain responses. To ensure no adverse heating events occur with liFUS modulation in a non-invasive manner, we perform initial work in swine to show that magnetic resonance thermometry imaging (MRTI) is capable of measuring <2.0 °C changes at the L5 DRG. Further, we show that our device can be constructed in an MR-compatible fashion to minimize artifact. METHODS: Three MRTI techniques (referenceless, corrected proton resonance frequency shift (PRFS), and PRFS) were applied to assess accuracy of detecting thermal changes at the L5 DRG in unheated euthanized swine. A region of interest (ROI) that includes the L5 DRG was delineated, within which MRTI temperature changes were spatially averaged (ground truth 0 °C). In separate experiments with phantoms, B0 field-inhomogeneity, RF transmit (B1+) and fast gradient echo (fSPGR) magnitude images were acquired to downselect liFUS device materials that produce the least MRI artifacts. RESULTS: Referenceless, corrected PRFS, and PRFS MRTI resulted in temperature measurements of 0.8 ± 1.1 °C, 1.1 ± 1.3 °C and 5.2 ± 5 °C, respectively. Both materials caused B0 perturbation but minimal B1+ and MRTI artifacts. The presence of imaging artifacts did not preclude thermal imaging of the region. SIGNIFICANCE: We provide preliminary data suggesting that referenceless MRTI can adequately detect small thermal changes at the DRG that may occur with neuromodulation, which is one of the first steps in creating a table of safe parameters for liFUS therapy in humans.


Subject(s)
Nerve Tissue , Thermometry , Humans , Animals , Swine , Magnetic Resonance Imaging/methods , Thermometry/methods , Phantoms, Imaging , Protons
2.
Neuromodulation ; 25(4): 504-510, 2022 06.
Article in English | MEDLINE | ID: mdl-35667768

ABSTRACT

OBJECTIVE: Chronic pain affects 7%-10% of Americans, occurs more frequently and severely in females, and available treatments have been shown to have less efficacy in female patients. Preclinical models addressing sex-specific treatment differences in the treatment of chronic pain have been limited. Here we examine the sex-specific effects of low intensity focused ultrasound (liFUS) in a modified sciatic nerve injury (SNI) model. MATERIALS AND METHODS: A modified SNI performed by ligating the common peroneal nerve (CPN) was used to measure sensory, behavioral pain responses, and nerve conduction studies in female and male rats, following liFUS of the L5 dorsal root ganglion. RESULTS: Using the same dose of liFUS in females and males of the same weight, CPN latency immediately after treatment was increased for 50 min in females compared to 25 min in males (p < 0.001). Improvements in mechanical pain thresholds after liFUS lasted significantly longer in females (seven days; p < 0.05) compared to males (three days; p < 0.05). In females, there was a significant improvement in depression-like behavior as a result of liFUS (N = 5; p < 0.01); however, because males never developed depression-like behavior there was no change after liFUS treatment. CONCLUSIONS: Neuromodulation with liFUS has a greater effect in female rats on CPN latency, mechanical allodynia duration, and depression-like behavior. In order to customize neuromodulatory techniques for different patient phenotypes, it is essential to understand how they may alter sex-specific pathophysiologies.


Subject(s)
Chronic Pain , Neuralgia , Peripheral Nerve Injuries , Animals , Disease Models, Animal , Female , Humans , Hyperalgesia/etiology , Hyperalgesia/therapy , Male , Neuralgia/therapy , Peripheral Nerve Injuries/therapy , Peroneal Nerve/diagnostic imaging , Peroneal Nerve/injuries , Rats
3.
Neurosci Lett ; 757: 135977, 2021 07 13.
Article in English | MEDLINE | ID: mdl-34023413

ABSTRACT

BACKGROUND: Changes in inflammatory cytokine levels contribute to the induction and maintenance of neuropathic pain. We have shown that external low intensity focused ultrasound (liFUS) reduces allodynia in a common peroneal nerve injury (CPNI). Here, we investigate an underlying mechanism of action for this treatment and measure the effect of liFUS on inflammatory markers. METHODS: Male rats were divided into four groups: CPNI/liFUS, CPNI/shamliFUS, shamCPNI/liFUS, and shamCPNI/shamliFUS. Mechanical nociceptive thresholds were measured using Von Frey filaments (VFF) to confirm the absence/presence of allodynia at baseline, after CPNI, and after liFUS. Commercial microarray and ELISA assays were used to assess cytokine expression in the treated L5 dorsal root ganglion (DRG) and dorsal horn (DH) tissue 24 and 72 h after liFUS. RESULTS: VFF thresholds were significantly reduced following CPNI in both groups that received the injury (p < 0.001). After liFUS, only the CPNI/liFUS cohort showed a significant increase in mechanical thresholds (p < 0.001). CPNI significantly increased TNFa, IL6, CNTF, IL1b (p < 0.05 for all) levels in the DRG and DH, compared to baseline, consistent with previous work in sciatic nerve injury. LiFUS in CPNI rats resulted in a decrease in these cytokines in DRG 72 h post-therapy (TNFa, IL6, CNTF and IL1b, p < 0.001). In the DH, IL1b, CNTF, and TNFa (p < 0.05 for all) decreased 72 h after liFUS. CONCLUSION: We have demonstrated that liFUS modifies inflammatory cytokines in both DRG and DH in CPNI rats. These data provide evidence that liFUS, reverses the allodynic phenotype, in part, by altering inflammatory cytokine pathways.


Subject(s)
Hyperalgesia/therapy , Neuralgia/therapy , Peripheral Nerve Injuries/complications , Ultrasonic Therapy/methods , Animals , Cytokines/metabolism , Disease Models, Animal , Ganglia, Spinal/immunology , Ganglia, Spinal/metabolism , Humans , Hyperalgesia/diagnosis , Hyperalgesia/immunology , Male , Neuralgia/diagnosis , Neuralgia/immunology , Peripheral Nerve Injuries/immunology , Peripheral Nerve Injuries/therapy , Peroneal Nerve/injuries , Rats , Rats, Sprague-Dawley , Signal Transduction/immunology , Signal Transduction/radiation effects , Spinal Cord Dorsal Horn/immunology , Spinal Cord Dorsal Horn/metabolism , Ultrasonic Waves
4.
J Neurosurg ; : 1-8, 2021 Apr 16.
Article in English | MEDLINE | ID: mdl-33862597

ABSTRACT

OBJECTIVE: The authors' laboratory has previously demonstrated beneficial effects of noninvasive low intensity focused ultrasound (liFUS), targeted at the dorsal root ganglion (DRG), for reducing allodynia in rodent neuropathic pain models. However, in rats the DRG is 5 mm below the skin when approached laterally, while in humans the DRG is typically 5-8 cm deep. Here, using a modified liFUS probe, the authors demonstrated the feasibility of using external liFUS for modulation of antinociceptive responses in neuropathic swine. METHODS: Two cohorts of swine underwent a common peroneal nerve injury (CPNI) to induce neuropathic pain. In the first cohort, pigs (14 kg) were iteratively tested to determine treatment parameters. liFUS penetration to the L5 DRG was verified by using a thermocouple to monitor tissue temperature changes and by measuring nerve conduction velocity (NCV) at the corresponding common peroneal nerve (CPN). Pain behaviors were monitored before and after treatment. DRG was evaluated for tissue damage postmortem. Based on data from the first cohort, a treatment algorithm was developed, parameter predictions were verified, and neuropathic pain was significantly modified in a second cohort of larger swine (20 kg). RESULTS: The authors performed a dose-response curve analysis in 14-kg CPNI swine. Specifically, after confirming that the liFUS probe could reach 5 cm in ex vivo tissue experiments, the authors tested liFUS in 14-kg CPNI swine. The mean ± SEM DRG depth was 3.79 ± 0.09 cm in this initial cohort. The parameters were determined and then extrapolated to larger animals (20 kg), and predictions were verified. Tissue temperature elevations at the treatment site did not exceed 2°C, and the expected increases in the CPN NCV were observed. liFUS treatment eliminated pain guarding in all animals for the duration of follow-up (up to 1 month) and improved allodynia for 5 days postprocedure. No evidence of histological damage was seen using Fluoro-Jade and H&E staining. CONCLUSIONS: The results demonstrate that a 5-cm depth can be reached with external liFUS and alters pain behavior and allodynia in a large-animal model of neuropathic pain.

5.
IEEE Trans Biomed Eng ; 68(6): 1838-1846, 2021 06.
Article in English | MEDLINE | ID: mdl-32924937

ABSTRACT

The primary objective of cancer intervention is the selective removal of malignant cells while conserving surrounding healthy tissues. However, the accessibility, size and shape of the cancer can make achieving appropriate margins a challenge. One minimally invasive treatment option for these clinical cases is interstitial needle based therapeutic ultrasound (NBTU). In this work, we develop a finite element model (FEM) capable of simulating continuous rotation of a directional NBTU applicator. The developed model was used to simulate the thermal deposition for different rotation trajectories. The actual thermal deposition patterns for the simulated trajectories were then evaluated using magnetic resonance thermal imaging (MRTI) in a porcine skin gelatin phantom. An MRI-compatible robot was used to control the rotation motion profile of the physical NBTU applicator to match the simulated trajectory. The model showed agreement when compared to experimental measurements with Pearson correlation coefficients greater than 0.839 when comparing temperature fields within an area of 12.6 mm radius from the ultrasound applicator. The average temperature error along a 6.3 mm radius profile from the applicator was 1.27 °C. The model was able to compute 1 s of thermal deposition by the applicator in 0.2 s on average with a 0.1 mm spatial resolution and 0.5 s time steps. The developed simulation demonstrates performance suitable for real-time control which may enable robotically-actuated closed-loop conformal tumor ablation.


Subject(s)
Magnetic Resonance Imaging , Ultrasonic Therapy , Animals , Phantoms, Imaging , Rotation , Swine , Ultrasonography
6.
Neuroscience ; 429: 264-272, 2020 03 01.
Article in English | MEDLINE | ID: mdl-32001366

ABSTRACT

Non-invasive treatment methods for neuropathic pain are lacking. We assess how modulatory low intensity focused ultrasound (liFUS) at the L5 dorsal root ganglion (DRG) affects behavioral responses and sensory nerve action potentials (SNAPs) in a common peroneal nerve injury (CPNI) model. Rats were assessed for mechanical and thermal responses using Von Frey filaments (VFF) and the hot plate test (HPT) following CPNI surgery. Testing was repeated 24 h after liFUS treatment. Significant increases in mechanical and thermal sensory thresholds were seen post-liFUS treatment, indicating a reduction in sensitivity to pain (p < 0.0001, p = 0.02, respectively). Animals who received CPNI surgery had significant increases in SNAP latencies compared to sham CPNI surgery animals (p = 0.0003) before liFUS treatment. LiFUS induced significant reductions in SNAP latency in both CPNI liFUS and sham CPNI liFUS cohorts, for up to 35 min post treatment. No changes were seen in SNAP amplitude and there was no evidence of neuronal degeneration 24 h after liFUS treatment, showing that liFUS did not damage the tissue being modulated. This is the first in vivo study of the impact of liFUS on peripheral nerve electrophysiology in a model of chronic pain. This study demonstrates the effects of liFUS on peripheral nerve electrophysiology in vivo. We found that external liFUS treatment results in transient decreased latency in common peroneal nerve (CPN) sensory nerve action potentials (SNAPs) with no change in signal amplitude.


Subject(s)
Peripheral Nerve Injuries , Peroneal Nerve , Animals , Ganglia, Spinal , Hyperalgesia , Rats , Rats, Sprague-Dawley , Rodentia
7.
Magn Reson Med ; 83(1): 240-253, 2020 01.
Article in English | MEDLINE | ID: mdl-31402512

ABSTRACT

PURPOSE: To develop and test in animal studies ex vivo and in vivo, an intravascular (IV) MRI-guided high-intensity focused ultrasound (HIFU) ablation method for targeting perivascular pathology with minimal injury to the vessel wall. METHODS: IV-MRI antennas were combined with 2- to 4-mm diameter water-cooled IV-ultrasound ablation catheters for IV-MRI on a 3T clinical MRI scanner. A software interface was developed for monitoring thermal dose with real-time MRI thermometry, and an MRI-guided ablation protocol developed by repeat testing on muscle and liver tissue ex vivo. MRI thermal dose was measured as cumulative equivalent minutes at 43°C (CEM43 ). The IV-MRI IV-HIFU protocol was then tested by targeting perivascular ablations from the inferior vena cava of 2 pigs in vivo. Thermal dose and lesions were compared by gross and histological examination. RESULTS: Ex vivo experiments yielded a 6-min ablation protocol with the IV-ultrasound catheter coolant at 3-4°C, a 30 mL/min flow rate, and 7 W ablation power. In 8 experiments, 5- to 10-mm thick thermal lesions of area 0.5-2 cm2 were produced that spared 1- to 2-mm margins of tissue abutting the catheters. The radial depths, areas, and preserved margins of ablation lesions measured from gross histology were highly correlated (r ≥ 0.79) with those measured from the CEM43 = 340 necrosis threshold determined by MRI thermometry. The psoas muscle was successfully targeted in the 2 live pigs, with the resulting ablations controlled under IV-MRI guidance. CONCLUSION: IV-MRI-guided, IV-HIFU has potential as a precision treatment option that could preserve critical blood vessel wall during ablation of nonresectable perivascular tumors or other pathologies.


Subject(s)
Blood Vessels/diagnostic imaging , Blood Vessels/pathology , High-Intensity Focused Ultrasound Ablation , Magnetic Resonance Imaging , Vena Cava, Inferior/diagnostic imaging , Animals , Chickens , In Vitro Techniques , Liver/diagnostic imaging , Muscle, Skeletal/diagnostic imaging , Psoas Muscles/diagnostic imaging , Psoas Muscles/pathology , Swine , Temperature , Thermometry
8.
Neurosurgery ; 84(5): 1138-1148, 2019 05 01.
Article in English | MEDLINE | ID: mdl-29905844

ABSTRACT

BACKGROUND: Ablative lesions are current treatments for epilepsy and brain tumors. Interstitial magnetic resonance (MR) guided focused ultrasound (iMRgFUS) may be an alternate ablation technique which limits thermal tissue charring as compared to laser therapy (LITT) and can produce larger ablation patterns nearer the surface than transcranial MR guided focused ultrasound (tcMRgFUS). OBJECTIVE: To describe our experience with interstitial focused ultrasound (iFUS) ablations in swine, using MR-guided robotically assisted (MRgRA) delivery. METHODS: In an initial 3 animals, we optimized the workflow of the robot in the MR suite and made modifications to the robotic arm to allow range of motion. Then, 6 farm pigs (4 acute, 2 survival) underwent 7 iMRgFUS ablations using MRgRA. We altered dosing to explore differences between thermal dosing in brain as compared to other tissues. Imaging was compared to gross examination. RESULTS: Our work culminated in adjustments to the MRgRA, iMRgFUS probes, and dosing, culminating in 2 survival surgeries; swine had ablations with no neurological sequelae at 2 wk postprocedure. Immediately following iMRgFUS therapy, diffusion-weighted imaging, and T1 weighted MR were accurate reflections of the ablation volume. T2 and fluid-attenuated inversion-recovery (FLAIR) images were accurate reflections of ablation volume 1-wk postprocedure. CONCLUSION: We successfully performed MRgRA iFUS ablation in swine and found intraoperative and postoperative imaging to correlate with histological examination. These data are useful to validate our system and to guide imaging follow-up for thermal ablation lesions in brain tissue from our therapy, tcMRgFUS, and LITT.


Subject(s)
Brain/surgery , High-Intensity Focused Ultrasound Ablation/methods , Robotic Surgical Procedures/methods , Animals , Magnetic Resonance Imaging/methods , Models, Animal , Sus scrofa , Swine , Workflow
9.
Brain Res ; 1699: 135-141, 2018 11 15.
Article in English | MEDLINE | ID: mdl-30077646

ABSTRACT

Chronic migraines (CM) are the third most common disease and are refractory to medical treatment in 15% of patients. Currently, temporary relief is achieved with steroid blocks or pulsed radiofrequency ablation, which have short-term benefits. Our project aims to develop a non-invasive treatment for medically refractory chronic migraine, which does not require a permanent implant. This project investigates the safety and effectiveness of pulsed focused ultrasound (FUS) in a validated rodent headache model of cutaneous allodynia associated with chronic migraine (CM) as compared to sumatriptan and ablative lesioning. We demonstrate a significant reduction in mechanical thresholds as measured through Von Frey filaments in CM in the forepaw and periorbital region (p < 0.001). Sumatriptan and pulsed FUS both significantly improve thresholds at day 3 after treatment in the periorbital region. Ablative lesioning has no effect. This study provides initial evidence that FUS may provide an important therapeutic option for patients suffering from CM.


Subject(s)
Hyperalgesia/therapy , Migraine Disorders/therapy , Ultrasonic Therapy , Animals , Disease Models, Animal , Hyperalgesia/etiology , Hyperalgesia/pathology , Hyperalgesia/physiopathology , Male , Migraine Disorders/complications , Migraine Disorders/pathology , Migraine Disorders/physiopathology , Pain Threshold , Peripheral Nerves/pathology , Random Allocation , Rats, Sprague-Dawley , Serotonin 5-HT1 Receptor Agonists/pharmacology , Skin , Sumatriptan/pharmacology
10.
Neurosurg Focus ; 44(2): E13, 2018 02.
Article in English | MEDLINE | ID: mdl-29385920

ABSTRACT

OBJECTIVE Minimally invasive procedures may allow surgeons to avoid conventional open surgical procedures for certain neurological disorders. This paper describes the iterative process for development of a catheter-based ultrasound thermal therapy applicator. METHODS Using an ultrasound applicator with an array of longitudinally stacked and angularly sectored tubular transducers within a catheter, the authors conducted experimental studies in porcine liver, in vivo and ex vivo, in order to characterize the device performance and lesion patterns. In addition, they applied the technique in a rodent model of Parkinson's disease to investigate the feasibility of its application in brain. RESULTS Thermal lesions with multiple shapes and sizes were readily achieved in porcine liver. The feasibility of catheter-based focused ultrasound in the treatment of brain conditions was demonstrated in a rodent model of Parkinson's disease. CONCLUSIONS The authors show proof of principle of a catheter-based ultrasound system that can create lesions with concurrent thermode-based measurements.


Subject(s)
Brain/diagnostic imaging , Catheterization/methods , Minimally Invasive Surgical Procedures/methods , Parkinsonian Disorders/diagnostic imaging , Ultrasonography, Interventional/methods , Animals , Brain/surgery , Parkinsonian Disorders/surgery , Rats , Swine
11.
Article in English | MEDLINE | ID: mdl-28761393

ABSTRACT

An intravascular MRI (IMRI) loopless antenna is combined for the first time with an intravascular water-cooled ultrasound ablation transducer as a possible tool for providing high-resolution MRI-guided ablations of pathological tissue via intravascular access. High resolution anatomical MRI, and real-time MRI thermometry were used to monitor ablation delivery in phantoms and tissue specimens. Results show that IMRI can guide IVUS-mediated directional ablation with minimal image artifacts. This permits the monitoring of thermal dose and therapy titration while minimizing potential thermal damage to the vessel wall.

12.
ACS Nano ; 9(11): 10695-10718, 2015 Nov 24.
Article in English | MEDLINE | ID: mdl-26435333

ABSTRACT

Repurposing of existing cancer drugs to overcome their physical limitations, such as insolubility, represents an attractive strategy to achieve enhanced therapeutic efficacy and broaden the range of clinical applications. Such an approach also promises to offer substantial cost savings in drug development efforts. Here we repurposed FDA-approved topical agent bexarotene (Targretin), currently in limited use for cutaneous manifestations of T-cell lymphomas, and re-engineer it for use in solid tumor applications by forming self-assembling nanobubbles. Physico-chemical characterization studies of the novel prodrug nanobubbles demonstrated their stability, enhanced target cell internalization capability, and highly controlled release profile in response to application of focused ultrasound energy. Using an in vitro model of hepatocellular carcinoma and an in vivo large animal model of liver ablation, we demonstrate the effectiveness of bexarotene prodrug nanobubbles when used in conjunction with catheter-based ultrasound, thereby highlighting the therapeutic promise of this trimodal approach.


Subject(s)
Drug Repositioning , Hyperthermia, Induced , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy , Tetrahydronaphthalenes/therapeutic use , Ultrasonics , Animals , Bexarotene , Catheters , Combined Modality Therapy , Disease Models, Animal , Electricity , Electrophoresis , Gene Expression Profiling , Gene Expression Regulation, Neoplastic , Hep G2 Cells , Humans , Hydrogen-Ion Concentration , Liver Neoplasms/genetics , Liver Neoplasms/pathology , Molecular Dynamics Simulation , Nanoparticles/chemistry , Prodrugs/chemical synthesis , Prodrugs/therapeutic use , Quantum Theory , Retinoid X Receptor alpha/agonists , Retinoid X Receptor alpha/metabolism , Spectrum Analysis, Raman , Sus scrofa , Tetrahydronaphthalenes/chemical synthesis , Thermodynamics , Ultrasonography
13.
IEEE Trans Biomed Eng ; 60(6): 1608-18, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23335657

ABSTRACT

This paper presents the results of a feasibility study to demonstrate the application of ultrasound RF time series imaging to accurately differentiate ablated and nonablated tissue. For 12 ex vivo and two in situ tissue samples, RF ultrasound signals are acquired prior to, and following, high-intensity ultrasound ablation. Spatial and temporal features of these signals are used to characterize ablated and nonablated tissue in a supervised-learning framework. In cross-validation evaluation, a subset of four features extracted from RF time series produce a classification accuracy of 84.5%, an area under ROC curve of 0.91 for ex vivo data, and an accuracy of 85% for in situ data. Ultrasound RF time series is a promising approach for characterizing ablated tissue.


Subject(s)
High-Intensity Focused Ultrasound Ablation/methods , Image Processing, Computer-Assisted/methods , Signal Processing, Computer-Assisted , Animals , Chickens , Feasibility Studies , Liver/surgery , Models, Biological , Muscle, Skeletal/surgery , Radio Waves , Swine
SELECTION OF CITATIONS