Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Phys ; 41(6): 061712, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24877807

ABSTRACT

PURPOSE: The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyond d(max) and to find ways to mitigate this dependence for measurements in phantoms. METHODS: Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam ("edge on," 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered. RESULTS: For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al2O3) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. CONCLUSIONS: The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinical in vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.


Subject(s)
Optically Stimulated Luminescence Dosimetry/instrumentation , Computer Simulation , Equipment Design , Monte Carlo Method , Particle Accelerators , Phantoms, Imaging , Photons , Radiation Equipment and Supplies , Radiotherapy Dosage , Rotation , Uncertainty , Water , X-Ray Microtomography
2.
FASEB J ; 21(12): 3329-37, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17536040

ABSTRACT

Aeration of the lung and the transition to air-breathing at birth is fundamental to mammalian life and initiates major changes in cardiopulmonary physiology. However, the dynamics of this process and the factors involved are largely unknown, because it has not been possible to observe or measure lung aeration on a breath-by-breath basis. We have used the high contrast and spatial resolution of phase contrast X-ray imaging to study lung aeration at birth in spontaneously breathing neonatal rabbits. As the liquid-filled fetal lungs provide little absorption or phase contrast, they are not visible and only become visible as they aerate, allowing a detailed examination of this process. Pups were imaged live from birth to determine the timing and spatial pattern of lung aeration, and relative levels of lung aeration were measured from the images using a power spectral analysis. We report the first detailed observations and measurements of lung aeration, demonstrating its dependence on inspiratory activity and body position; dependent regions aerated at much slower rates. The air/liquid interface moved toward the distal airways only during inspiration, with little proximal movement during expiration, indicating that trans-pulmonary pressures play an important role in airway liquid clearance at birth. Using these imaging techniques, the dynamics of lung aeration and the critical role it plays in regulating the physiological changes at birth can be fully explored.


Subject(s)
Lung/diagnostic imaging , Parturition , Respiration , Animals , Animals, Newborn , Female , Lung/anatomy & histology , Lung Volume Measurements , Pregnancy , Rabbits , Radiography/methods , Random Allocation
SELECTION OF CITATIONS
SEARCH DETAIL
...