Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
PLoS One ; 19(3): e0291186, 2024.
Article in English | MEDLINE | ID: mdl-38446762

ABSTRACT

BACKGROUND: Commercial electroencephalography (EEG) devices have become increasingly available over the last decade. These devices have been used in a wide variety of fields ranging from engineering to cognitive neuroscience. PURPOSE: The aim of this study was to chart peer-review articles that used consumer-grade EEG devices to collect neural data. We provide an overview of the research conducted with these relatively more affordable and user-friendly devices. We also inform future research by exploring the current and potential scope of consumer-grade EEG. METHODS: We followed a five-stage methodological framework for a scoping review that included a systematic search using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR) guidelines. We searched the following online databases: PsycINFO, MEDLINE, Embase, Web of Science, and IEEE Xplore. We charted study data according to application (BCI, experimental research, validation, signal processing, and clinical) and location of use as indexed by the first author's country. RESULTS: We identified 916 studies that used data recorded with consumer-grade EEG: 531 were reported in journal articles and 385 in conference papers. Emotiv devices were used most, followed by the NeuroSky MindWave, OpenBCI, interaXon Muse, and MyndPlay Mindband. The most common usage was for brain-computer interfaces, followed by experimental research, signal processing, validation, and clinical purposes. CONCLUSIONS: Consumer-grade EEG is a useful tool for neuroscientific research and will likely continue to be used well into the future. Our study provides a comprehensive review of their application, as well as future directions for researchers who plan to use these devices.


Subject(s)
Brain-Computer Interfaces , Electroencephalography , Engineering
2.
Heliyon ; 9(8): e18433, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37554801

ABSTRACT

The development of online research platforms has made data collection more efficient and representative of populations. However, these benefits have not been available for use with cognitive neuroscience tools such as electroencephalography (EEG). In this study, we introduce an approach for remote EEG data collection. We demonstrate how an experiment can be built via the EmotivPRO Builder and deployed to the EmotivLABS website where it can be completed by participants who own EMOTIV EEG headsets. To demonstrate the data collection technique, we collected EEG while participants engaged in a resting state task where participants sat with their eyes open and then eyes closed for 2 min each. We observed a significant difference in alpha power between the two conditions thereby demonstrating the well-known alpha suppression effect. Thus, we demonstrate that EEG data collection, particularly for frequency domain analysis, can be successfully conducted online.

3.
IBRO Neurosci Rep ; 12: 399-410, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35601693

ABSTRACT

Financial constraints usually hinder students, especially those in low-middle income countries (LMICs), from seeking mental health interventions. Hence, it is necessary to identify effective, affordable and sustainable counter-stress measures for college students in the LMICs context. This study examines the sustained effects of mindfulness practice on the psychological outcomes and brain activity of students, especially when they are exposed to stressful situations. Here, we combined psychological and electrophysiological methods (EEG) to investigate the sustained effects of an 8-week-long standardized Mindfulness-Based Stress Reduction (MBSR) intervention on the brain activity of college students. We found that the Test group showed a decrease in negative emotional states after the intervention, compared to the no statistically significant result of the Control group, as indicated by the Perceived Stress Scale (PSS) (33% reduction in the negative score) and Depression, Anxiety, Stress Scale (DASS-42) scores (nearly 40% reduction of three subscale scores). Spectral analysis of EEG data showed that this intervention is longitudinally associated with increased frontal and occipital lobe alpha band power. Additionally, the increase in alpha power is more prevalent when the Test group was being stress-induced by cognitive tasks, suggesting that practicing MBSR might enhance the practitioners' tolerance of negative emotional states. In conclusion, MBSR intervention led to a sustained reduction of negative emotional states as measured by both psychological and electrophysiological metrics, which supports the adoption of MBSR as an effective and sustainable stress-countering approach for students in LMICs.

4.
PeerJ ; 9: e10700, 2021.
Article in English | MEDLINE | ID: mdl-33614271

ABSTRACT

BACKGROUND: The use of consumer-grade electroencephalography (EEG) systems for research purposes has become more prevalent. In event-related potential (ERP) research, it is critical that these systems have precise and accurate timing. The aim of the current study was to investigate the timing reliability of event-marking solutions used with Emotiv commercial EEG systems. METHOD: We conducted three experiments. In Experiment 1 we established a jitter threshold (i.e. the point at which jitter made an event-marking method unreliable). To do this, we introduced statistical noise to the temporal position of event-marks of a pre-existing ERP dataset (recorded with a research-grade system, Neuroscan SynAmps2 at 1,000 Hz using parallel-port event-marking) and calculated the level at which the waveform peaks differed statistically from the original waveform. In Experiment 2 we established a method to identify 'true' events (i.e. when an event should appear in the EEG data). We did this by inserting 1,000 events into Neuroscan data using a custom-built event-marking system, the 'Airmarker', which marks events by triggering voltage spikes in two EEG channels. We used the lag between Airmarker events and events generated by Neuroscan as a reference for comparisons in Experiment 3. In Experiment 3 we measured the precision and accuracy of three types of Emotiv event-marking by generating 1,000 events, 1 s apart. We measured precision as the variability (standard deviation in ms) of Emotiv events and accuracy as the mean difference between Emotiv events and true events. The three triggering methods we tested were: (1) Parallel-port-generated TTL triggers; (2) Arduino-generated TTL triggers; and (3) Serial-port triggers. In Methods 1 and 2 we used an auxiliary device, Emotiv Extender, to incorporate triggers into the EEG data. We tested these event-marking methods across three configurations of Emotiv EEG systems: (1) Emotiv EPOC+ sampling at 128 Hz; (2) Emotiv EPOC+ sampling at 256 Hz; and (3) Emotiv EPOC Flex sampling at 128 Hz. RESULTS: In Experiment 1 we found that the smaller P1 and N1 peaks were attenuated at lower levels of jitter relative to the larger P2 peak (21 ms, 16 ms, and 45 ms for P1, N1, and P2, respectively). In Experiment 2, we found an average lag of 30.96 ms for Airmarker events relative to Neuroscan events. In Experiment 3, we found some lag in all configurations. However, all configurations exhibited precision of less than a single sample, with serial-port-marking the most precise when paired with EPOC+ sampling at 256 Hz. CONCLUSION: All Emotiv event-marking methods and configurations that we tested were precise enough for ERP research as the precision of each method would provide ERP waveforms statistically equivalent to a research-standard system. Though all systems exhibited some level of inaccuracy, researchers could easily account for these during data processing.

5.
PeerJ ; 8: e9713, 2020.
Article in English | MEDLINE | ID: mdl-32864218

ABSTRACT

BACKGROUND: Previous work has validated consumer-grade electroencephalography (EEG) systems for use in research. Systems in this class are cost-effective and easy to set up and can facilitate neuroscience outside of the laboratory. The aim of the current study was to determine if a new consumer-grade system, the Emotiv EPOC Saline Flex, was capable of capturing research-quality data. METHOD: The Emotiv system was used simultaneously with a research-grade EEG system, Neuroscan Synamps2, to collect EEG data across 16 channels during five well-established paradigms: (1) a mismatch negativity (MMN) paradigm that involved a passive listening task in which rare deviant (1,500 Hz) tones were interspersed amongst frequent standard tones (1,000 Hz), with instructions to ignore the tones while watching a silent movie; (2) a P300 paradigm that involved an active listening task in which participants were asked to count rare deviant tones presented amongst frequent standard tones; (3) an N170 paradigm in which participants were shown images of faces and watches and asked to indicate whether the images were upright or inverted; (4) a steady-state visual evoked potential (SSVEP) paradigm in which participants passively viewed a flickering screen (15 Hz) for 2 min; and (5) a resting state paradigm in which participants sat quietly with their eyes open and then closed for 3 min each. RESULTS: The MMN components and P300 peaks were equivalent between the two systems (BF10 = 0.25 and BF10 = 0.26, respectively), with high intraclass correlations (ICCs) between the ERP waveforms (>0.81). Although the N170 peak values recorded by the two systems were different (BF10 = 35.88), ICCs demonstrated that the N170 ERP waveforms were strongly correlated over the right hemisphere (P8; 0.87-0.97), and moderately-to-strongly correlated over the left hemisphere (P7; 0.52-0.84). For the SSVEP, the signal-to-noise ratio (SNR) was larger for Neuroscan than Emotiv EPOC Flex (19.94 vs. 8.98, BF10 = 51,764), but SNR z-scores indicated a significant brain response at the stimulus frequency for both Neuroscan (z = 12.47) and Flex (z = 11.22). In the resting state task, both systems measured similar alpha power (BF10 = 0.28) and higher alpha power when the eyes were closed than open (BF10 = 32.27). CONCLUSIONS: The saline version of the Emotiv EPOC Flex captures data similar to that of a research-grade EEG system. It can be used to measure reliable auditory and visual research-quality ERPs. In addition, it can index SSVEP signatures and is sensitive to changes in alpha oscillations.

6.
Memory ; 26(5): 664-671, 2018 05.
Article in English | MEDLINE | ID: mdl-29065777

ABSTRACT

This project investigated the underlying mechanisms that boost false remember responses when participants receive study words that are both semantically and phonologically similar to a critical lure. Participants completed a memory task in which they were presented with a list of words all associated with a critical lure. Included within the list of semantic associates was a target that was either semantically associated (e.g., yawn) to the critical lure (e.g., sleep) or shared the initial (e.g., slam) or final (e.g., beep) phoneme(s) with the critical lure. After hearing the list, participants recalled each list item and indicated whether they just knew it was on the list or if they instead recollected specific contextual details of that item's presentation. We found that inserting an initial phonemic overlap target boosted experiences of recollection, but only when semantically related associates were presented beforehand. The results are consistent with models of spoken word recognition and show that established semantic context plus initial phonemic overlap play important roles in boosting false recollection.


Subject(s)
Association , Memory/physiology , Repression, Psychology , Female , Humans , Male , Neuropsychological Tests
SELECTION OF CITATIONS
SEARCH DETAIL