Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Br J Surg ; 106(4): 355-363, 2019 03.
Article in English | MEDLINE | ID: mdl-30802304

ABSTRACT

BACKGROUND: Infectious complications and anastomotic leakage affect approximately 30 per cent of patients after colorectal cancer surgery. The aim of this multicentre randomized trial was to investigate whether selective decontamination of the digestive tract (SDD) reduces these complications of elective colorectal cancer surgery. METHODS: The effectiveness of SDD was evaluated in a multicentre, open-label RCT in six centres in the Netherlands. Patients with colorectal cancer scheduled for elective curative surgery with a primary anastomosis were eligible. Oral colistin, tobramycin and amphotericin B were administered to patients in the SDD group to decontaminate the digestive tract. Both treatment and control group received intravenous cefazolin and metronidazole for perioperative prophylaxis. Mechanical bowel preparation was given for left-sided colectomies, sigmoid and anterior resections. Anastomotic leakage was the primary outcome; infectious complications and mortality were secondary outcomes. RESULTS: The outcomes for 228 patients randomized to the SDD group and 227 randomized to the control group were analysed. The trial was stopped after interim analysis demonstrated that superiority was no longer attainable. Effective SDD was confirmed by interspace DNA profiling analysis of rectal swabs. Anastomotic leakage was observed in 14 patients (6·1 per cent) in the SDD group and in 22 patients (9·7 per cent) in the control group (odds ratio (OR) 0·61, 95 per cent c.i. 0·30 to 1·22). Fewer patients in the SDD group had one or more infectious complications than patients in the control group (14·9 versus 26·9 per cent respectively; OR 0·48, 0·30 to 0·76). Multivariable analysis indicated that SDD reduced the rate of infectious complications (OR 0·47, 0·29 to 0·76). CONCLUSION: SDD reduces infectious complications after colorectal cancer resection but did not significantly reduce anastomotic leakage in this trial. Registration number: NCT01740947 ( https://www.clinicaltrials.gov).


Subject(s)
Colectomy/methods , Colorectal Neoplasms/surgery , Decontamination/methods , Elective Surgical Procedures/methods , Surgical Wound Infection/prevention & control , Academic Medical Centers , Aged , Analysis of Variance , Anastomosis, Surgical/methods , Antibiotic Prophylaxis , Colectomy/adverse effects , Colorectal Neoplasms/pathology , Elective Surgical Procedures/adverse effects , Female , Follow-Up Studies , Hospitals, University , Humans , Male , Middle Aged , Multivariate Analysis , Netherlands , Preoperative Care/methods , Reference Values , Risk Assessment , Tobramycin/administration & dosage , Treatment Outcome
2.
Prev Med ; 52(6): 448-51, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21457725

ABSTRACT

OBJECTIVE: The population benefit of screening depends not only on the effectiveness of the test, but also on adherence, which, for colorectal cancer (CRC) screening remains low. An advance notification letter may increase adherence, however, no population-based randomized trials have been conducted to provide evidence of this. METHOD: In 2008, a representative sample of the Dutch population (aged 50-74 years) was randomized. All 2493 invitees in group A were sent an advance notification letter, followed two weeks later by a standard invitation. The 2507 invitees in group B only received the standard invitation. Non-respondents in both groups were sent a reminder 6 weeks after the invitation. RESULTS: The advance notification letters resulted in a significantly higher adherence (64.4% versus 61.1%, p-value 0.019). Multivariate logistic regression analysis showed no significant interactions between group and age, sex, or socio-economic status. Cost analysis showed that the incremental cost per additional detected advanced neoplasia due to sending an advance notification letter was € 957. CONCLUSION: This population-based randomized trial demonstrates that sending an advance notification letter significantly increases adherence by 3.3%. The incremental cost per additional detected advanced neoplasia is acceptable. We therefore recommend that such letters are incorporated within the standard CRC-screening invitation process.


Subject(s)
Colorectal Neoplasms/prevention & control , Mass Screening/statistics & numerical data , Patient Acceptance of Health Care/statistics & numerical data , Reminder Systems/statistics & numerical data , Aged , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/economics , Cost-Benefit Analysis , Female , Guideline Adherence/statistics & numerical data , Humans , Male , Mass Screening/economics , Middle Aged , Netherlands , Reminder Systems/economics
3.
Br J Cancer ; 100(7): 1103-10, 2009 Apr 07.
Article in English | MEDLINE | ID: mdl-19337257

ABSTRACT

Immunochemical faecal occult blood testing (FIT) provides quantitative test results, which allows optimisation of the cut-off value for follow-up colonoscopy. We conducted a randomised population-based trial to determine test characteristics of FIT (OC-Sensor micro, Eiken, Japan) screening at different cut-off levels and compare these with guaiac-based faecal occult blood test (gFOBT) screening in an average risk population. A representative sample of the Dutch population (n=10 011), aged 50-74 years, was 1 : 1 randomised before invitation to gFOBT and FIT screening. Colonoscopy was offered to screenees with a positive gFOBT or FIT (cut-off 50 ng haemoglobin/ml). When varying the cut-off level between 50 and 200 ng ml(-1), the positivity rate of FIT ranged between 8.1% (95% CI: 7.2-9.1%) and 3.5% (95% CI: 2.9-4.2%), the detection rate of advanced neoplasia ranged between 3.2% (95% CI: 2.6-3.9%) and 2.1% (95% CI: 1.6-2.6%), and the specificity ranged between 95.5% (95% CI: 94.5-96.3%) and 98.8% (95% CI: 98.4-99.0%). At a cut-off value of 75 ng ml(-1), the detection rate was two times higher than with gFOBT screening (gFOBT: 1.2%; FIT: 2.5%; P<0.001), whereas the number needed to scope (NNscope) to find one screenee with advanced neoplasia was similar (2.2 vs 1.9; P=0.69). Immunochemical faecal occult blood testing is considerably more effective than gFOBT screening within the range of tested cut-off values. From our experience, a cut-off value of 75 ng ml(-1) provided an adequate positivity rate and an acceptable trade-off between detection rate and NNscope.


Subject(s)
Colorectal Neoplasms/diagnosis , Guaiac , Occult Blood , Aged , Colonoscopy , Female , Hemoglobins/analysis , Humans , Immunochemistry , Male , Middle Aged , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...