Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 93(8): 084904, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-36050106

ABSTRACT

Time delayed pump-probe measurement techniques, such as Time Domain Thermoreflectance (TDTR), have opened up a wealth of opportunities for metrology at ultra-fast timescales and nanometer length scales. For nanoscale thermal transport measurements, typical thermal lifetimes used to measure thermal conductivity and thermal boundary conductance span from sub-picosecond to ∼6 nanoseconds. In this work, we demonstrate a simple rearrangement and validation of a configuration that allows access to the entire 12.5 ns time delay available in the standard pulse train. By reconfiguring a traditional TDTR system so that the pump and probe arrive concurrently when the delay stage reaches its midpoint, followed by unwrapping the temporal scan, we obtain a dataset that is bounded only by the oscillator repetition rate. Sensitivity analysis along with conducted measurements shows that great increases in measurement sensitivity are available with this approach, particularly for thin films with low thermal conductivities.

2.
Rev Sci Instrum ; 88(7): 074903, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28764517

ABSTRACT

Simplified heat-transfer models are widely employed by heated probe scanning thermal microscopy techniques for determining thermal conductivity of test samples. These parameters have generally been assumed to be independent of sample properties; however, there has been little investigation of this assumption in non-contact mode, and the impact calibration procedures have on sample thermal conductivity results has not been explored. However, there has been little investigation of the commonly used assumption that thermal exchange parameters are sample independent in non-contact mode, or of the impact calibration procedures have on sample thermal conductivity results. This article establishes conditions under which quantitative, localized, non-contact measurements using scanning thermal microscopy with heated microprobes may be most accurately performed. The work employs a three-dimensional finite element (3DFE) model validated using experimental results and no fitting parameters, to determine the dependence of a heated microprobe thermal resistance as a function of sample thermal conductivity at several values of probe-to-sample clearance. The two unknown thermal exchange parameters were determined by fitting the 3DFE simulated probe thermal resistance with the predictions of a simplified probe heat transfer model, for two samples with different thermal conductivities. This calibration procedure known in experiments as the intersection method was simulated for sample thermal conductivities in the range of 0.1-50 W m-1 K-1 and clearance values in the 260-1010 nm range. For a typical Wollaston wire microprobe geometry as simulated here, both the thermal exchange radius and thermal contact resistance were found to increase with the sample thermal conductivity in the low thermal conductivity range while they remained approximately constant for thermal conductivities >1 W m-1 K-1, with similar trends reported for all clearance values investigated. It is shown that versatile sets of calibration samples for the intersection method should employ either medium range (1 W m-1 K-1) and (2 W m-1 K-1) thermal conductivities, or wide range (0.5 W m-1 K-1) and (50 W m-1 K-1). The medium range yielded results within 1.5%-20.4% of the expected values of thermal conductivity for specimens with thermal conductivity within 0.1-10 W m-1 K-1, while the wide range yielded values within 0.5%-19.4% in the same range.

3.
Nanoscale ; 7(37): 15404-12, 2015 Oct 07.
Article in English | MEDLINE | ID: mdl-26335503

ABSTRACT

This work discusses measurement of thermal conductivity (k) of films using a scanning hot probe method in the 3ω mode and investigates the calibration of thermal contact parameters, specifically the thermal contact resistance (R(th)C) and thermal exchange radius (b) using reference samples with different thermal conductivities. R(th)C and b were found to have constant values (with b = 2.8 ± 0.3 µm and R(th)C = 44,927 ± 7820 K W(-1)) for samples with thermal conductivity values ranging from 0.36 W K(-1) m(-1) to 1.1 W K(-1) m(-1). An independent strategy for the calibration of contact parameters was developed and validated for samples in this range of thermal conductivity, using a reference sample with a previously measured Seebeck coefficient and thermal conductivity. The results were found to agree with the calibration performed using multiple samples of known thermal conductivity between 0.36 and 1.1 W K(-1) m(-1). However, for samples in the range between 16.2 W K(-1) m(-1) and 53.7 W K(-1) m(-1), calibration experiments showed the contact parameters to have considerably different values: R(th)C = 40,191 ± 1532 K W(-1) and b = 428 ± 24 nm. Finally, this work demonstrates that using these calibration procedures, measurements of both highly conductive and thermally insulating films on substrates can be performed, as the measured values obtained were within 1-20% (for low k) and 5-31% (for high k) of independent measurements and/or literature reports. Thermal conductivity results are presented for a SiGe film on a glass substrate, Te film on a glass substrate, polymer films (doped with Fe nano-particles and undoped) on a glass substrate, and Au film on a Si substrate.

SELECTION OF CITATIONS
SEARCH DETAIL
...