Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Cardiol Young ; : 1-4, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38812431

ABSTRACT

Success of atrioventricular septal defect repair is defined by post-operative atrioventricular valve function and presence of residual intracardiac shunting. We evaluated differences in interpretation of atrioventricular valve function and residual defects between transesophageal and transthoracic echocardiography in a contemporary cohort of infants undergoing atrioventricular septal defect repair. Among 106 patients, we identified an increase in left and right atrioventricular valve regurgitation, right atrioventricular valve inflow gradient, and increased detection rate of residual intracardiac shunting on transthoracic compared to transesophageal echocardiograms, although residual shunts identified only on transthoracic echocardiogram were not haemodynamically significant. Findings may help inform expectation of post-operative transthoracic echocardiogram findings based on intraoperative assessment.

2.
J Am Soc Echocardiogr ; 37(6): 603-612, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38432347

ABSTRACT

BACKGROUND: Mitral stenosis/aortic atresia (MS/AA) has been reported as a high-risk variant of hypoplastic left heart syndrome (HLHS), potentially related to ventriculocoronary connections (VCCs) or endocardial fibroelastosis (EFE) and myocardial hypoperfusion. We aimed to identify echocardiographic and clinical factors associated with early death or transplant in this group. METHODS: Patients with HLHS MS/AA treated at our center between 2000 and 2020 were included. Pre-stage I palliation echocardiograms were reviewed. Certain imaging factors, such as determination of VCC, EFE, and measurement of tricuspid annular plane systolic excursion were measured from retrospective review of preoperative images; others were derived from clinical reports. Groups were compared according to primary outcome of death or transplant prior to stage II palliation. RESULTS: Of 141 patients included, 39 (27.7%) experienced a primary outcome. Ventriculocoronary connections were identified in 103 (73.0%) patients and EFE in 95 (67.4%) patients. Among imaging variables, smaller ascending aorta size (median, 2.2 [interquartile range (IQR) 1.7-2.8] vs 2.6 [2.2-3.4] mm, P = .01) was associated with primary outcome. There was similar frequency of VCC (74.4% vs 72.5%, P = .83), EFE (59.0% vs 72.5%, P = .19), moderate or greater tricuspid regurgitation (5.1% vs 5.9%, P = 1.00), and similar right ventricular systolic function (indexed tricuspid annular plane systolic excursion 32.5 ± 7.3 vs 31.4 ± 7.2 mm/m2, P = .47) in the primary outcome group compared to other patients. Clinical factors associated with primary outcome included lower birth weight (mean, 2.8 ± SD 0.8 vs 3.3 ± 0.5 kg, P = .0003), gestational age <37 weeks (31.6% vs 4.9%, P < .0001), longer cardiopulmonary bypass time (median, 112 [IQR, 93-162] vs 82 [71-119] minutes, P = .001), longer intensive care unit length of stay (median, 19 [IQR, 10-30] vs 10 [7-15] days, P = .001), and extracorporeal membrane oxygenation following stage I palliation (43.6% vs 8.8%, P < .0001). Presence of VCCs and EFE was not associated with death or transplant after controlling for birth weight and era of stage I palliation. CONCLUSIONS: In one of the largest reported single-center cohorts of HLHS MS/AA, there were few pre-stage I palliation imaging characteristics associated with primary outcome. Imaging findings evaluated in this study, including the presence of VCC and/or EFE as determined using highly sensitive echocardiogram criteria, should not preclude intervention, although impact on long-term outcomes requires further evaluation.


Subject(s)
Echocardiography , Hypoplastic Left Heart Syndrome , Mitral Valve Stenosis , Humans , Hypoplastic Left Heart Syndrome/complications , Hypoplastic Left Heart Syndrome/diagnostic imaging , Hypoplastic Left Heart Syndrome/surgery , Hypoplastic Left Heart Syndrome/physiopathology , Female , Male , Retrospective Studies , Mitral Valve Stenosis/complications , Mitral Valve Stenosis/physiopathology , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/diagnosis , Echocardiography/methods , Infant, Newborn , Infant
3.
Cardiol Young ; 34(4): 846-853, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37905328

ABSTRACT

OBJECTIVE: To characterise transesophageal echocardiography practice patterns among paediatric cardiac surgical centres in the United States and Canada. METHODS: A 42-question survey was sent to 80 echocardiography laboratory directors at paediatric cardiology centres with surgical programmes in the United States and Canada. Question domains included transesophageal echocardiography centre characteristics, performance and reporting, equipment use, trainee participation, and quality assurance. RESULTS: Fifty of the 80 centres (62.5%) responded to the survey. Most settings were academic (86.0%) with 42.0% of centres performing > 350 surgical cases/year. The median number of transesophageal echocardiograms performed/cardiologist/year was 50 (26, 73). Pre-operative transesophageal echocardiography was performed in most surgical cases by 91.7% of centres. Transesophageal echocardiography was always performed by most centres following Norwood, Glenn, and Fontan procedures and by < 10% of centres following coarctation repair. Many centres with a written guideline allowed transesophageal echocardiography transducer use at weights below manufacturer recommendations (50.0 and 61.1% for neonatal and paediatric transducers, respectively). Most centres (36/37, 97.3%) with categorical fellowships had rotations which included transesophageal echocardiography participation. Large surgical centres (>350 cases/year) had higher median number of transesophageal echocardiograms/cardiologist/year (75.5 [53, 86] versus 35 [20, 52], p < 0.001) and more frequently used anaesthesia for diagnostic transesophageal echocardiography ≥ 67% of time (100.0 versus 62.1%, p = 0.001). CONCLUSIONS: There is significant variability in transesophageal echocardiography practice patterns and training requirements among paediatric cardiology centres in the United States and Canada. Findings may help inform programmatic decisions regarding transesophageal echocardiography expectations, performance and reporting, equipment use, trainee involvement, and quality assurance.


Subject(s)
Cardiology , Fontan Procedure , Infant, Newborn , United States , Humans , Child , Echocardiography, Transesophageal , Echocardiography , Cardiology/education , Canada
6.
Pediatr Crit Care Med ; 24(11): e547-e555, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37219966

ABSTRACT

OBJECTIVES: To describe factors associated with failed extubation (FE) in neonates following cardiovascular surgery, and the relationship with clinical outcomes. DESIGN: Retrospective cohort study. SETTING: Twenty-bed pediatric cardiac ICU (PCICU) in an academic tertiary care children's hospital. PATIENTS: Neonates admitted to the PCICU following cardiac surgery between July 2015 and June 2018. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Patients who experienced FE were compared with patients who were successfully extubated. Variables associated with FE ( p < 0.05) from univariate analysis were considered for inclusion in multivariable logistic regression. Univariate associations of FE with clinical outcomes were also examined. Of 240 patients, 40 (17%) experienced FE. Univariate analyses revealed associations of FE with upper airway (UA) abnormality (25% vs 8%, p = 0.003) and delayed sternal closure (50% vs 24%, p = 0.001). There were weaker associations of FE with hypoplastic left heart syndrome (25% vs 13%, p = 0.04), postoperative ventilation greater than 7 days (33% vs 15%, p = 0.01), Society of Thoracic Surgeons-European Association for Cardio-Thoracic Surgery (STAT) category 5 operations (38% vs 21%, p = 0.02), and respiratory rate during spontaneous breathing trial (median 42 vs 37 breaths/min, p = 0.01). In multivariable analysis, UA abnormalities (adjusted odds ratio [AOR] 3.5; 95% CI, 1.4-9.0), postoperative ventilation greater than 7 days (AOR 2.3; 95% CI, 1.0-5.2), and STAT category 5 operations (AOR 2.4; 95% CI, 1.1-5.2) were independently associated with FE. FE was also associated with unplanned reoperation/reintervention during hospital course (38% vs 22%, p = 0.04), longer hospitalization (median 29 vs 16.5 d, p < 0.0001), and in-hospital mortality (13% vs 3%, p = 0.02). CONCLUSIONS: FE in neonates occurs relatively commonly following cardiac surgery and is associated with adverse clinical outcomes. Additional data are needed to further optimize periextubation decision-making in patients with multiple clinical factors associated with FE.


Subject(s)
Cardiac Surgical Procedures , Thoracic Surgery , Infant, Newborn , Child , Humans , Retrospective Studies , Airway Extubation/adverse effects , Risk Factors , Cardiac Surgical Procedures/adverse effects
7.
J Pediatr ; 260: 113462, 2023 09.
Article in English | MEDLINE | ID: mdl-37172812

ABSTRACT

OBJECTIVE: To report intermediate cardiac magnetic resonance (CMR) findings of coronavirus disease 2019 (COVID-19) vaccine-associated myopericarditis (C-VAM) and compare with classic myocarditis. STUDY DESIGN: Retrospective cohort study including children diagnosed with C-VAM from May 2021 through December 2021 with early and intermediate CMR. Patients with classic myocarditis from January 2015 through December 2021 and intermediate CMR were included for comparison. RESULTS: There were 8 patients with C-VAM and 20 with classic myocarditis. Among those with C-VAM, CMR performed at a median 3 days (IQR 3, 7) revealed 2 of 8 patients with left ventricular ejection fraction <55%, 7 of 7 patients receiving contrast with late gadolinium enhancement (LGE), and 5 of 8 patients with elevated native T1 values. Borderline T2 values suggestive of myocardial edema were present in 6 of 8 patients. Follow-up CMRs performed at a median 107 days (IQR 97, 177) showed normal ventricular systolic function, T1, and T2 values; 3 of 7 patients had LGE. At intermediate follow-up, patients with C-VAM had fewer myocardial segments with LGE than patients with classic myocarditis (4/119 vs 42/340, P = .004). Patients with C-VAM also had a lower frequency of LGE (42.9 vs 75.0%) and lower percentage of left ventricular ejection fraction <55% compared with classic myocarditis (0.0 vs 30.0%), although these differences were not statistically significant. Five patients with classic myocarditis did not receive an early CMR, leading to some selection bias in study design. CONCLUSIONS: Patients with C-VAM had no evidence of active inflammation or ventricular dysfunction on intermediate CMR, although a minority had persistent LGE. Intermediate findings in C-VAM revealed less LGE burden compared with classic myocarditis.


Subject(s)
COVID-19 , Myocarditis , Child , Humans , Myocarditis/diagnostic imaging , Myocarditis/etiology , Stroke Volume , Contrast Media , Ventricular Function, Left , Retrospective Studies , COVID-19 Vaccines/adverse effects , Gadolinium , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Magnetic Resonance Imaging, Cine , Predictive Value of Tests
9.
Cardiol Young ; 33(3): 444-448, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35411842

ABSTRACT

BACKGROUND: Understanding how cardiovascular structure and physiology guide management is critically important in paediatric cardiology. However, few validated educational tools are available to assess trainee knowledge. To address this deficit, paediatric cardiologists and fellows from four institutions collaborated to develop a multimedia assessment tool for use with medical students and paediatric residents. This tool was developed in support of a novel 3-dimensional virtual reality curriculum created by our group. METHODS: Educational domains were identified, and questions were iteratively developed by a group of clinicians from multiple centres to assess understanding of key concepts. To evaluate content validity, content experts completed the assessment and reviewed items, rating item relevance to educational domains using a 4-point Likert scale. An item-level content validity index was calculated for each question, and a scale-level content validity index was calculated for the assessment tool, with scores of ≥0.78 and ≥0.90, respectively, representing excellent content validity. RESULTS: The mean content expert assessment score was 92% (range 88-97%). Two questions yielded ≤50% correct content expert answers. The item-level content validity index for 29 out of 32 questions was ≥0.78, and the scale-level content validity index was 0.92. Qualitative feedback included suggestions for future improvement. Questions with ≤50% content expert agreement and item-level content validity index scores <0.78 were removed, yielding a 27-question assessment tool. CONCLUSIONS: We describe a multi-centre effort to create and validate a multimedia assessment tool which may be implemented within paediatric trainee cardiology curricula. Future efforts may focus on content refinement and expansion to include additional educational domains.


Subject(s)
Cardiology , Internship and Residency , Students, Medical , Humans , Child , Multimedia , Education, Medical, Graduate/methods , Cardiology/education
10.
Cardiol Young ; 33(3): 410-414, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35466894

ABSTRACT

OBJECTIVES: Virtual reality has emerged as a unique educational modality for medical trainees. However, incorporation of virtual reality curricula into formal training programmes has been limited. We describe a multi-centre effort to develop, implement, and evaluate the efficacy of a virtual reality curriculum for residents participating in paediatric cardiology rotations. METHODS: A virtual reality software program ("The Stanford Virtual Heart") was utilised. Users are placed "inside the heart" and explore non-traditional views of cardiac anatomy. Modules for six common congenital heart lesions were developed, including narrative scripts. A prospective case-control study was performed involving three large paediatric residency programmes. From July 2018 to June 2019, trainees participating in an outpatient cardiology rotation completed a 27-question, validated assessment tool. From July 2019 to February 2020, trainees completed the virtual reality curriculum and assessment tool during their cardiology rotation. Qualitative feedback on the virtual reality experience was also gathered. Intervention and control group performances were compared using univariate analyses. RESULTS: There were 80 trainees in the control group and 52 in the intervention group. Trainees in the intervention group achieved higher scores on the assessment (20.4 ± 2.9 versus 18.8 ± 3.8 out of 27 questions answered correctly, p = 0.01). Further analysis showed significant improvement in the intervention group for questions specifically testing visuospatial concepts. In total, 100% of users recommended integration of the programme into the residency curriculum. CONCLUSIONS: Virtual reality is an effective and well-received adjunct to clinical curricula for residents participating in paediatric cardiology rotations. Our results support continued virtual reality use and expansion to include other trainees.


Subject(s)
Cardiology , Internship and Residency , Virtual Reality , Humans , Child , Case-Control Studies , Curriculum , Clinical Competence
11.
Am J Cardiol ; 165: 95-100, 2022 02 15.
Article in English | MEDLINE | ID: mdl-34895701

ABSTRACT

In patients with congenitally corrected transposition of the great arteries (ccTGA) and hemodynamically significant concomitant lesions, physiologic repair may be undertaken, in which the circulation is septated but the morphologic right ventricle (RV) remains the systemic ventricle. Patients without significant concomitant lesions may be observed without surgery, with a similar physiologic result. We compared cardiovascular magnetic resonance measures of ventricular size and function in patients with physiologically repaired and unrepaired ccTGA. Patients with ccTGA who underwent cardiovascular magnetic resonance at our center between September 2007 and July 2019 were analyzed. In 38 patients identified (12, physiologically repaired; 26, unrepaired; mean age 34.5 [18.7 to 52.0] years), there was a higher proportion of RV ejection fraction ≤45% in physiologically repaired (75% vs unrepaired 35%, p = 0.02). Physiologically repaired patients had worse left ventricle global longitudinal strain (-14.9% ± 5.0% vs unrepaired patients -18.4% ± 2.7%, p = 0.04). The difference in tricuspid regurgitant fraction between groups did not achieve statistical significance (physiologically repaired 27.4 ± 11.1% vs unrepaired patients 19.2 ± 13.0%, p = 0.08). Evaluation for late gadolinium enhancement was more commonly undertaken in physiologically repaired patients (8 of 12 vs unrepaired 7 of 26, p = 0.03) and present more frequently in the left ventricle in physiologically repaired patients in patients evaluated (6 of 8 vs unrepaired 0 of 7, p = 0.01). In conclusion, ventricular function is decreased in patients with ccTGA undergoing physiologic repair compared with those without previous surgery. These cohorts should be considered separately when using ventricular function as an outcome. RV dysfunction is concerning for long-term outcomes following physiologic repair.


Subject(s)
Congenitally Corrected Transposition of the Great Arteries/diagnostic imaging , Tricuspid Valve Insufficiency/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Right/diagnostic imaging , Adolescent , Adult , Cardiac Surgical Procedures/methods , Congenitally Corrected Transposition of the Great Arteries/physiopathology , Congenitally Corrected Transposition of the Great Arteries/surgery , Female , Humans , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Cine , Male , Middle Aged , Plastic Surgery Procedures/methods , Stroke Volume , Tricuspid Valve Insufficiency/physiopathology , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Right/physiopathology , Ventricular Function, Left , Ventricular Function, Right , Young Adult
12.
Am J Cardiol ; 122(6): 1074-1078, 2018 09 15.
Article in English | MEDLINE | ID: mdl-30075896

ABSTRACT

Cardiovascular magnetic resonance imaging (CMR) has emerged as a powerful tool to illuminate cardiovascular pathology in Anderson-Fabry disease (AFD); however, further study is required to develop clinically useful monitoring paradigms. The objective of this study was to retrospectively evaluate strain, native septal T1 values, and standard CMR measurements in a cohort of AFD patients to characterize useful measures of cardiovascular dysfunction that may be derived from a CMR platform. Eighteen patients were identified (n = 8 males) and divided according to presence or absence of left ventricular hypertrophy (LVH). Biometric data were gathered and native T1 and strain values were measured for all patients. Patients with LVH were older and had significantly lower native T1 measured at the apical septal (893 ± 78 vs 1044 ± 217 ms, p = 0.035), midventricular septal (864 ± 76 vs 988 ± 67 ms, p = 0.016), and basal septal (867 ± 58 vs 1027 ± 84 ms, p = 0.006) regions. Circumferential strain was more positive in patients with LVH (-13.5% ± 5.0% vs -18.7% ± 2.7%, p = 0.042), but longitudinal strain was not significantly different between groups. Patients with LVH had higher stroke volumes (114.5 ± 9.7 vs 96.7 ± 17.8 ml, p = 0.050), but other standard CMR measures were not significantly different. In conclusion, AFD patients with LVH have reduced native T1 and more positive circumferential strain compared to those without. The basal septum may be an appropriate region for standard measure of native T1 in this population.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Cardiovascular Diseases/diagnostic imaging , Cardiovascular Diseases/etiology , Cardiovascular Diseases/physiopathology , Fabry Disease/complications , Fabry Disease/diagnostic imaging , Fabry Disease/physiopathology , Magnetic Resonance Imaging/methods , Adolescent , Adult , Aged , Contrast Media , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Software
13.
Am J Cardiol ; 120(2): 251-255, 2017 Jul 15.
Article in English | MEDLINE | ID: mdl-28550929

ABSTRACT

Anderson-Fabry Disease (AFD) is a lysosomal storage disorder that results in progressive cardiovascular hypertrophy, scarring, and arrhythmia burden; yet, the early cardiac phenotype of AFD is still poorly defined. To further characterize early cardiac features in AFD, we evaluated electrocardiographic and clinical findings contained in a local cohort of pediatric AFD patients and arrhythmia data in children enrolled in the Fabry Registry. Twenty-six local patients aged <18 years were identified (average age 9.7 ± 3.8 years, n = 12 males). Sinus bradycardia was the most frequent rhythm abnormality (23%), followed by ectopic atrial rhythm (12%) and premature atrial contractions (8%). No PR, QRS, or QTc intervals were prolonged. First-degree atrioventricular block developed in 1 female during follow-up. Chest pain (35%) and palpitations (23%) were highly prevalent complaints in clinical follow-up and did not differ significantly between genders. Structural findings included aortic root dilation in 3 patients and concurrent aortic insufficiency in 1. Among 593 patients aged < 18 years with electrocardiographic data identified in the Fabry Registry, sinus bradycardia, defined as heart rate <60 beats per minute per registry guidelines, was the most common arrhythmia (12.3%). In conclusion, clinical findings and subtle abnormalities of conduction, rhythm, and structure point toward a heterogeneous inception of Fabry cardiomyopathy. Bradycardia, common in adults, is frequent even among children with AFD. Given the potential for early initiation of enzyme replacement therapy to reduce cardiovascular morbidity, continued work to develop paradigms of therapy and longitudinal cardiovascular surveillance is warranted.


Subject(s)
Arrhythmias, Cardiac/etiology , Electrocardiography , Fabry Disease/diagnosis , Heart Conduction System/physiopathology , Heart Rate/physiology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Child , Fabry Disease/complications , Fabry Disease/physiopathology , Female , Humans , Male , Retrospective Studies
14.
J Org Chem ; 74(4): 1721-9, 2009 Feb 20.
Article in English | MEDLINE | ID: mdl-19140722

ABSTRACT

Photoremovable protecting groups that can reveal biologically important functional groups through one- and two-photon excitation (1PE and 2PE, respectively) have promise in regulating physiological function in a temporally and spatially restricted manner. Only a few chromophores have sufficient sensitivity to 2PE suitable for use as "caging groups" in physiology experiments. It would be useful to develop structure-property relationships of chromophores, so that chromophores with high two-photon uncaging action cross-sections (delta(u)) can be designed. The 8-bromo-7-hydroxyquinolinyl chromophore (BHQ) releases a variety of functional groups through 1PE and 2PE. Swapping the bromine substituent for a nitro (NHQ), cyano (CyHQ), or chloro (CHQ) or exchanging the hydroxy for dimethylamino (DMAQ and DMAQ-Cl) or sulfhydryl (TQ) significantly alters the photochemical and photophysical properties of the quinoline chromophore. CyHQ-OAc demonstrated a 3-fold increase in sensitivity for acetate release, whereas NHQ-OAc was photochemically insensitive. The quantum efficiencies (Q(u)) of the amino and sulfhydryl derivatives were about an order of magnitude lower than that of BHQ-OAc. All of the chromophores showed diminished sensitivity to 2PE compared to BHQ-OAc, but the CyHQ, DMAQ, and DMAQ-Cl chromophores are sufficiently sensitive for physiological use. The high sensitivity of CyHQ to 1PE will be useful in biological applications requiring short exposure with low light intensity.


Subject(s)
Photolysis , Photons , Quinolines/chemistry , Kinetics , Spectrometry, Fluorescence , Spectrophotometry, Ultraviolet
SELECTION OF CITATIONS
SEARCH DETAIL
...