Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 7: 40490, 2017 01 10.
Article in English | MEDLINE | ID: mdl-28071734

ABSTRACT

The design, fabrication and characterization of a novel metamaterial absorber based camera with subwavelength spatial resolution are investigated. The proposed camera is featured with simple and lightweight design, easy portability, low cost, high resolution and sensitivity, and minimal image interference or distortion to the original field distribution. The imaging capability of the proposed camera was characterized in both near field and far field ranges. The experimental and simulated near field images both reveal that the camera produces qualitatively accurate images with negligible distortion to the original field distribution. The far field demonstration was done by coupling the designed camera with a microwave convex lens. The far field results further demonstrate that the camera can capture quantitatively accurate electromagnetic wave distribution in the diffraction limit. The proposed camera can be used in application such as non-destructive image and beam direction tracer.

2.
J Am Anim Hosp Assoc ; 51(3): 176-9, 2015.
Article in English | MEDLINE | ID: mdl-25955143

ABSTRACT

An apparently healthy adult female Chihuahua was presented for elective ovariohysterectomy. After induction of general anesthesia, but prior to the start of the surgery, air was inadvertently administered to the patient via the i.v. fluid line. The patient convulsed, became apneic, arrested, and died despite attempted cardiopulmonary resuscitation. At necropsy, the pericardial sac was incised and filled with water to entirely submerge the intact heart. The right ventricular free wall was punctured, releasing several air bubbles from the right ventricle. Death was attributed to venous air embolism based on the clinical history, gross findings, and paucity of underlying gross and microscopic pathology that might have predisposed the dog to an anesthetic-related death. The discussion of this case includes a review of previously reported veterinary cases of fatal venous air embolism, including the varied mechanisms of embolus formation, the potential impact of pre-existing cardiopulmonary disease, and the methods used to detect emboli. This report outlines the events of fatal iatrogenic venous air embolization and emphasizes the importance of considering this entity in the case of sudden death of a patient with an indwelling catheter in order to pursue either appropriate diagnostic tests or necropsy techniques to aid in the diagnosis.


Subject(s)
Anesthesia/veterinary , Dog Diseases/pathology , Embolism, Air/veterinary , Anesthesia/adverse effects , Animals , Dogs , Embolism, Air/pathology , Fatal Outcome , Female , Heart Arrest/etiology , Heart Arrest/veterinary , Hysterectomy/veterinary , Ovariectomy/veterinary
3.
Sci Rep ; 4: 6301, 2014 Sep 09.
Article in English | MEDLINE | ID: mdl-25200005

ABSTRACT

On the heels of metamaterial absorbers (MAs) which produce near perfect electromagnetic (EM) absorption and emission, we propose a universal electromagnetic energy conversion adapter (UEECA) based on MA. By choosing the appropriate energy converting sensors, the UEECA is able to achieve near 100% signal transfer ratio between EM energy and various forms of energy such as thermal, DC electric, or higher harmonic EM energy. The inherited subwavelength dimension and the EM field intensity enhancement can further empower UEECA in many critical applications such as energy harvesting, photoconductive antennas, and nonlinear optics. The principle of UEECA is understood with a transmission line model, which further provides a design strategy that can incorporate a variety of energy conversion devices. The concept is experimentally validated at a microwave frequency with a signal transfer ratio of 96% by choosing an RF diode as the energy converting sensor.

4.
J Forensic Sci ; 51(6): 1334-43, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17199619

ABSTRACT

The submission to forensic laboratories of unknown specimens suspected of being biological or chemical warfare agents has increased tremendously with the threat of terrorism. Oftentimes, a threatening correspondence that contains hoax materials is intended to make the recipient(s) believe they have been exposed to a toxin. In some cases, the perpetrator can use standard household products, such as detergents and soaps. Once these materials are received, they become forensic evidence and may be analyzed for identification and/or comparison with known seized material from a suspect(s). Two separate studies were conducted using different analytical protocols for bar soaps. In the first set, the forensic laboratory at the United States Secret Service conducted tests on 68 bars of soap using solid-phase microextraction and gas chromatography coupled with mass spectrometry. The 68 different soaps displayed unique total ion chromatogram profiles. Energy-dispersive X-ray analysis in conjunction with scanning electron microscopy was also used to characterize 46 of the 68 soaps as a preliminary study. In a second set of studies, as part of a homicide investigation, the laboratory at the California Department of Justice, Riverside, conducted examinations on 13 bars of soap by utilizing Fourier transform-infrared spectroscopy. The case study demonstrated that it is possible to distinguish some bar soaps using infrared analysis. Furthermore, the bar soaps could be distinguished from typical laundry detergents using this technique.

5.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 6245-8, 2006.
Article in English | MEDLINE | ID: mdl-17946365

ABSTRACT

In this paper, a telemetry and contact-less powering system consisting of an implantable bio-MEMS sensor with a miniature printed square spiral chip antenna and an external wearable garment with printed loop antenna is investigated. The implantable chip antenna and the wearable garment pick-up antenna are in close proximity to each other and hence couple inductively through their near-fields and behave as the primary and the secondary circuits of a transformer, respectively. The numerical and experimental results are graphically presented, and include the design parameter values as a function of the geometry and the relative magnetic near-field intensity as a function of the angle, for the implantable chip antenna.


Subject(s)
Biomedical Engineering/methods , Equipment Design , Monitoring, Ambulatory/instrumentation , Telemetry/instrumentation , Biomedical Engineering/instrumentation , Computer Communication Networks , Electrodes , Electromagnetic Fields , Equipment Failure Analysis , Humans , Microcomputers , Miniaturization , Monitoring, Ambulatory/methods , Radio Waves , Telemetry/methods , Transducers
6.
J Forensic Sci ; 49(2): 364-70, 2004 Mar.
Article in English | MEDLINE | ID: mdl-15027562

ABSTRACT

Gel ink pens have become a common writing instrument in the United States. Questioned document examiners often attempt to optically differentiate gel inks from each other and from other non-ballpoint ink writings (e.g., those from roller-ball pens). Since early formulations were primarily pigment-based, they do not elute when analyzed by thin-layer chromatography. However, recent gel ink formulations (i.e., within the past five years) include dye-based inks that can be easily separated. This study differentiates black gel inks using optical and chemical techniques. The techniques include: microscopy, visible and near infrared reflectance, near infrared luminescence, thin-layer chromatography (TLC), spot tests, and gas chromatography/mass spectrometry (GC/MS). As a result of this study a flow chart has been developed allowing for a systematic determination of a questioned ink. In addition, an analysis of volatile compounds found in gel inks revealed that there are some unique ingredients that may be found in gel inks that are not typically found in other non-ballpoint inks.

7.
J Forensic Sci ; 49(1): 155-9, 2004 Jan.
Article in English | MEDLINE | ID: mdl-14979363

ABSTRACT

Developing and implementing a generally accepted procedure for the dating of ink found on documents using dynamic approaches has been a very formidable undertaking by forensic document examiners. 2-Phenoxyethanol (PE), a common volatile organic compound found in ballpoint inks, has been recognized for over a decade as a solvent that evaporates as ink ages. More recently, investigations have focused on the solvent loss ratio of PE prior to and after heating. To determine how often PE occurs in ink formulations, the authors analyzed 633 ballpoint inks utilizing a gas chromatograph/mass spectrometer. 2-Phenoxyethanol was identified in 85% (237/279) and 83% (293/354) of black and blue inks, respectively.

8.
J Forensic Sci ; 48(5): 1163-71, 2003 Sep.
Article in English | MEDLINE | ID: mdl-14535687

ABSTRACT

Thermal transfer printing refers to printing processes that utilize heat to produce an image by either physical or chemical means or by a combination of both. As the technology has improved and the supplies have become less expensive, the use of thermal printing in the personal and business markets has increased significantly. Specifically, dye diffusion thermal transfer and thermal mass transfer have become predominant in the production of counterfeit credit cards, drivers' licenses, and other types of documents produced on plastic media. Chemical analysis by means of thin layer chromatography (TLC) has proven to be useful in characterizing various types of inks (e.g., writing and inkjet inks). In this study, the authors examined 81 different samples that included a total of 54 printer samples (43 photographic prints on paper and eleven plastic card samples) and 27 printer ribbons. A new TLC method was developed and tested utilizing a solvent system (80% n-hexane, 3% methyl ethyl ketone, and 17% ethyl acetate) that is capable of producing excellent resolution.

SELECTION OF CITATIONS
SEARCH DETAIL
...