1.
Eye Contact Lens ; 44(3): 190-199, 2018 May.
Article in English | MEDLINE | ID: mdl-27768615

ABSTRACT

PURPOSE: This study hypothesized that a traditional high-water contact lens of moderate oxygen transmissibility (Dk/t) is noninferior to common silicone hydrogel (SH) lenses worn for daily wear with respect to measures of hypoxic stress. METHODS: Thirty-six habitual contact lens wearers completed wear of three lens types worn in a randomized order: etafilcon A (ACUVUE 2, control), lotrafilcon B (Air Optix Aqua), and comfilcon A (Biofinity). Central corneal thickness (CT) and limbal hyperemia were measured >2 hr after waking and after 6 to 8 hr of wear on days 1 and 7. Endothelial bleb formation was measured on day 1 of each lens type. Noninferiority of etafilcon A, with respect to the other two lens types, was assumed if the following difference margins of equivalence were met: <1.5% for corneal swelling, <0.5 grade for limbal hyperemia, and <1% area of endothelial blebs. Outcomes were modeled using generalized linear mixed modeling techniques. RESULTS: All lenses showed reductions in least-square mean estimates of CT on both days: etafilcon A -0.26% at day 1 and -0.31% at day 7; lotrafilcon B -1.11% at day 1 and -1.06% at day 7; comfilcon A -0.63% at day 1 and -0.84% at day 7. The difference in mean swelling between etafilcon A and lotrafilcon B was 0.85% at day 1 (95% confidence interval [0.4%-1.3%]) and 0.75% at day 7 (0.3%-1.2%). The difference in mean swelling between etafilcon A and comfilcon A was 0.37% at day 1 (-0.1% to 0.8%) and 0.53% at day 7 (0.1%-1.0%). For limbal redness, etafilcon A fell within 0.1 grade of lotrafilcon B and 0.18 grade of comfilcon A. For endothelial bleb formation, etafilcon A fell within 0.45% of lotrafilcon B and 0.23% of comfilcon A. CONCLUSION: The etafilcon A control lens resulted in corneal deswelling throughout the day as did the SH lens types. Limbal hyperemia and endothelial bleb formation with all lenses were negligible, and noninferiority assumptions were met between the lens types for all outcomes. Equivalence of etafilcon A with respect to the two SH lenses for three measures of hypoxic stress was demonstrated.


Subject(s)
Contact Lenses, Hydrophilic/adverse effects , Cornea/physiopathology , Corneal Edema/etiology , Hypoxia/etiology , Adult , Blister/pathology , Corneal Edema/physiopathology , Cross-Over Studies , Endothelium, Corneal/pathology , Female , Humans , Hydrogel, Polyethylene Glycol Dimethacrylate , Hydrogels , Limbus Corneae/pathology , Male , Methacrylates , Middle Aged , Prospective Studies , Silicones , Stress, Physiological/physiology , Young Adult
2.
Optom Vis Sci ; 94(4): 448-457, 2017 04.
Article in English | MEDLINE | ID: mdl-28195933

ABSTRACT

PURPOSE: To determine whether mucin ball (MB) formation is protective against corneal infiltrative events (CIEs) as previously reported. METHODS: Two hundred eighty-two eligible participants were enrolled at three sites in the USA. Participants began a 1-month continuous wear run-in period with high modulus lotrafilcon A lenses to assess their ability to form MBs (phase 1). Subsequently, they were stratified by this characteristic and randomized to balafilcon A or comfilcon A lenses for 7-day extended wear and followed for 1 year (phase 2). MB formation in each phase was defined as repeated presence of any MBs on a person level. Multivariable Cox proportional hazards regression was used to model the probability of a CIE as a function of MB formation in each phase and other covariates. RESULTS: Of the 282 participants who entered phase 1, 218 of them entered the phase 2 randomized trial during which 33 CIEs occurred. Overall, 74%, 61%, and 79% of participants repeatedly produced MBs in lotrafilcon A, balafilcon A, and comfilcon A lenses, respectively. Early repeated MB presence in phase 1 with lotrafilcon A lenses significantly increased the rate of CIEs in phase 2 (12-month follow-up) by 466% (HR 4.66, 95% confidence interval 1.10-19.79, P = .0372). Repeated, longer-term MB presence during wear of balafilcon A or comfilcon A in phase 2 did not significantly reduce the incidence of CIEs; however, it significantly decreased the rate of CIEs by 62% (hazard ratio (HR) 0.380, 95% confidence interval 0.145-0.998, P = .0494). CONCLUSIONS: The overarching hypothesis that MB formation is protective against CIEs throughout extended wear was not supported. Although a protective effect of longer-term MB presence on rate of CIEs was detected, early-onset MB formation substantially increased the hazard for CIE in subsequent wear with different lens types.


Subject(s)
Bacteria/isolation & purification , Contact Lenses, Extended-Wear/microbiology , Corneal Ulcer/prevention & control , Eye Infections, Bacterial/prevention & control , Hydrogels , Mucins/physiology , Silicones , Adult , Colony Count, Microbial , Corneal Ulcer/diagnosis , Corneal Ulcer/microbiology , Eye Infections, Bacterial/diagnosis , Eye Infections, Bacterial/microbiology , Female , Follow-Up Studies , Humans , Male , Proportional Hazards Models , Risk Factors
3.
Cornea ; 35(12): 1578-1583, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27560033

ABSTRACT

PURPOSE: To document the time course and resolution of contact lens-related corneal infiltrative events (CIEs) comparing slit-lamp images with anterior segment ocular coherence tomography (AS-OCT) images. METHODS: Six silicone hydrogel (SiHy) soft contact lens (SCL) wearers presenting with newly diagnosed symptomatic CIEs were monitored with slit-lamp images, detailed drawings, and AS-OCT until the resolution of the CIE. A final follow-up visit was completed 4 weeks after CIE resolution to determine whether scar formation was present. Positive controls were 2 SiHy SCL wearers with established (inactive) corneal scars, and negative controls were 2 SiHy SCL wearers with clear corneas. High- and low-contrast logMAR visual acuities were measured, and subjective symptom questionnaires were completed at all visits. RESULTS: Clinical signs, vision, and symptoms improved in tandem with the resolution of the CIEs as measured by imaging methods. Calibrated measures of infiltrate width from a slit-lamp biomicroscope appear to be similar to calibrated images from AS-OCT. CONCLUSIONS: Although further studies are needed to develop standardized procedures, AS-OCT can be a useful tool to characterize the development, progression, and resolution of corneal infiltrates as an objective measure of resolution and scar formation.


Subject(s)
Contact Lenses, Hydrophilic/adverse effects , Keratitis/diagnosis , Keratitis/etiology , Leukocytes/pathology , Disease Progression , Female , Fluorophotometry , Follow-Up Studies , Humans , Keratitis/physiopathology , Keratitis/therapy , Male , Pilot Projects , Prospective Studies , Risk Factors , Slit Lamp , Surveys and Questionnaires , Tomography, Optical Coherence , Visual Acuity/physiology , Young Adult
4.
Prog Retin Eye Res ; 53: 140-174, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27094372

ABSTRACT

Some recent research has resulted in a hypothesis that there is a common 'lid wiper' region that is apposite to the ocular surface or anterior lens surface (where contact lenses are worn), responsible for spreading tears during blinking. In the upper eyelid, it extends about 0.6 mm from the crest of the sharp posterior (inner) lid border (i.e. the mucocutaneous junction, or line of Marx) to the subtarsal fold superiorly and from the medial upper punctum to the lateral canthus horizontally. Histologically, it is seen as an epithelial elevation comprising of stratified epithelium with a transitional conjunctival structure of (moving posteriorly) squamous cells then cuboidal cells, with some parakeratinised cells and goblet cells. Lid wiper epitheliopathy (LWE) denotes staining of the lid wiper observed after instillation of dyes such as fluorescein, rose bengal or lissamine green. There have been some reports of higher rates of LWE in dry eye patients and contact lens wearers, but others have failed to find such associations. The primary cause of LWE is thought to be increased friction between the lid wiper and ocular or anterior contact lens surface due to inadequate lubrication, which could be caused by dry eye and may be exacerbated by factors such as abnormal blinking patterns, poor contact lens surface lubricity and adverse environmental influences. Recent evidence suggests that LWE is associated with sub-clinical inflammation. LWE has the potential to provide the missing mechanistic link between clinical observation and symptoms associated with dry eye and contact lens wear. Clinical and fundamental research into LWE is still in its infancy and in many instances equivocal; however, it is an idea that provides a potentially important new avenue for further investigation of anterior eye discomfort associated with ocular dryness and contact lens wear.


Subject(s)
Conjunctival Diseases/pathology , Epithelium, Corneal/physiopathology , Epithelium/pathology , Eyelid Diseases/pathology , Contact Lenses/adverse effects , Eyelids/physiopathology , Humans
5.
Cornea ; 34(9): 1179-85, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26203747

ABSTRACT

PURPOSE: A novel property evaluation methodology was used to determine the elusive value for the human corneal coefficient of friction (CoF). METHODS: Using a microtribometer on 28 fresh human donor corneas with intact epithelia, the CoF was determined in 4 test solutions (≥5 corneas/solution): tear-mimicking solution (TMS) in borate-buffered saline (TMS-PS), TMS in phosphate-buffered saline (TMS-PBS), TMS with HEPES-buffered saline (TMS-HEPES), and tear-like fluid in PBS (TLF-PBS). RESULTS: Mean (SD) CoF values ranged from 0.006 to 0.015 and were 0.013 (0.010) in TMS-PS, 0.006 (0.003) in TMS-PBS, 0.014 (0.005) in TMS-HEPES, and 0.015 (0.009) in TLF-PBS. Statistically significant differences were shown for TMS-PBS versus TLF (P = 0.0424) and TMS-PBS versus TMS-HEPES (P = 0.0179), but not for TMS-PBS versus TMS-PS (P = 0.2389). CONCLUSIONS: Successful measurement of the fresh human corneal tissue CoF was demonstrated, with values differing in the evaluated buffer solutions, within this limited sample size.


Subject(s)
Cornea/physiology , Friction/physiology , Materials Testing/instrumentation , Models, Biological , Aged , Aged, 80 and over , Female , Humans , Lubrication , Male , Stress, Mechanical , Tissue Donors