Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
J Biomed Mater Res A ; 104(4): 966-74, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26662937

ABSTRACT

One obstacle in neural repair is facilitating axon growth long enough to reach denervated targets. Recent studies show that axonal growth is accelerated by applying tension to bundles of neurites, and additional studies show that mechanical tension is critical to all neurite growth. However, no studies yet describe how individual neurons respond to tensile forces applied to cell bodies and neurites simultaneously; neither do any test motor neurons, a phenotype critical to neural repair. Here we examine the growth of dissociated motor neurons on stretchable substrates. E15 spinal motor neurons were cultured on poly-lactide-co-glycolide films stretched at 4.8, 9.6, or 14.3 mm day(-1). Morphological analysis revealed that substrate stretching has profound effects on developing motor neurons. Stretching increases major neurite length; it also forces neuritogenesis to occur nearest poles of the cell closest to the sources of tension. Stretching also reduces the number of neurites per neuron. These data show that substrate stretching affects neuronal morphology by specifying locations on the cell where neuritogenesis occurs and favoring major neurite growth at the expense of minor neurites. These results serve as a building block for development of new techniques to control and improve the growth of neurons for nerve repair purposes.


Subject(s)
Biocompatible Materials/chemistry , Lactic Acid/chemistry , Motor Neurons/cytology , Neurites/metabolism , Neurogenesis , Polyglycolic Acid/chemistry , Animals , Cells, Cultured , Motor Neurons/metabolism , Motor Neurons/ultrastructure , Neurites/ultrastructure , Polylactic Acid-Polyglycolic Acid Copolymer , Rats, Sprague-Dawley , Stress, Mechanical
2.
Sci Rep ; 4: 5512, 2014 Jul 01.
Article in English | MEDLINE | ID: mdl-24981707

ABSTRACT

Mechanical properties of tumors differ substantially from normal cells and tissues. Changes in stiffness or elasticity regulate pro-metastatic behaviors of cancer cells, but effects have been documented predominantly in isolated cells or in vitro cell culture systems. To directly link relative stiffness of tumors to cancer progression, we combined a mouse model of metastatic breast cancer with ex vivo measurements of bulk moduli of freshly excised, intact tumors. We found a high, inverse correlation between bulk modulus of resected tumors and subsequent local recurrence and metastasis. More compliant tumors were associated with more frequent, larger local recurrences and more extensive metastases than mice with relatively stiff tumors. We found that collagen content of resected tumors correlated with bulk modulus values. These data establish that relative differences in tumor stiffness correspond with tumor progression and metastasis, supporting further testing and development of tumor compliance as a prognostic biomarker in breast cancer.


Subject(s)
Adenocarcinoma/physiopathology , Adenocarcinoma/secondary , Breast Neoplasms/physiopathology , Neoplasm Recurrence, Local/physiopathology , Adenocarcinoma/pathology , Animals , Breast Neoplasms/pathology , Cell Line, Tumor , Elastic Modulus , Female , Hardness , Mice , Mice, Inbred C57BL , Neoplasm Recurrence, Local/pathology , Prognosis , Stress, Mechanical
3.
Ultrasound Med Biol ; 40(9): 2244-51, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24968758

ABSTRACT

This study uses high-resolution ultrasound to examine the growth and development of engineered oral mucosal tissues manufactured under aseptic conditions. The specimens are a commercially available natural tissue scaffold, AlloDerm, and oral keratinocytes seeded onto AlloDerm to form an ex vivo-produced oral mucosal equivalent (EVPOME) suitable for intra-oral grafting. The seeded cells produce a keratinized protective upper layer that smooths out any remaining surface irregularities on the underlying AlloDerm. Two-dimensional acoustic imaging of unseeded AlloDerm and developing EVPOMEs was performed on each day of their growth and development, each tissue specimen being imaged under aseptic conditions (total time from seeding to maturation: 11 d). Ultrasonic monitoring offers us the ability to determine the constituents of the EVPOME that are responsible for changes in its mechanical behavior during the manufacturing process. Ultrasonic monitoring affords us an opportunity to non-invasively assess, in real time, tissue-engineered constructs before release for use in patient care.


Subject(s)
Collagen , Mouth Mucosa/diagnostic imaging , Mouth Mucosa/growth & development , Tissue Engineering/methods , Tissue Scaffolds , Cells, Cultured , Humans , Ultrasonography
4.
Tissue Eng Part C Methods ; 19(5): 345-51, 2013 May.
Article in English | MEDLINE | ID: mdl-23072525

ABSTRACT

This study examines the use of high-resolution ultrasound to monitor changes in the morphology and nonlinear elastic properties of engineered oral mucosal tissues under normal and thermally stressed culture conditions. Nonlinear elastic properties were determined by first developing strain maps from acoustic ultrasound, followed by fitting of nonlinear stress-strain data to a 1-term Ogden model. Testing examined a clinically developed ex vivo produced oral mucosa equivalent (EVPOME). As seeded cells proliferate on an EVPOME surface, they produce a keratinized protective upper layer that fills in and smoothens out surface irregularities. These transformations can also alter the nonlinear stress/strain parameters as EVPOME cells differentiate. This EVPOME behavior is similar to those of natural oral mucosal tissues and in contrast to an unseeded scaffold. If ultrasonic monitoring could be developed, then tissue cultivation could be adjusted in-process to account for biological variations in their development of the stratified cellular layer. In addition to ultrasonic testing, an in-house-built compression system capable of accurate measurements on small (∼1.0-1.5 cm(2)) tissue samples is presented. Results showed a near 2.5-fold difference in the stiffness properties between the unstressed EVPOME and the noncell-seeded acellular scaffold (AlloDerm(®)). There were also 4×greater differences in root mean square values of the thickness in the unseeded AlloDerm compared to the mature unstressed EVPOME; this is a strong indicator for quantifying surface roughness.


Subject(s)
Elasticity , Microscopy, Acoustic/methods , Mouth Mucosa/physiology , Nonlinear Dynamics , Stress, Mechanical , Temperature , Tissue Engineering/methods , Collagen/pharmacology , Elasticity/drug effects , Humans , Mouth Mucosa/drug effects , Surface Properties
5.
Ultrasound Med Biol ; 37(10): 1734-42, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21871704

ABSTRACT

Acoustic microscopy was used to monitor an ex vivo produced oral mucosal equivalent (EVPOME) developed on acellular cadaveric dermis (AlloDerm®). As seeded cells adhered and grew, they filled in and smoothed out the surface irregularities, followed by the production of a keratinized protective outermost layer. If noninvasive in vitro ultrasonic monitoring of these cellular changes could be developed, then tissue cultivation could be adjusted in-process to account for biologic variations in the development of these stratified cell layers. Cultured keratinocytes (from freshly obtained oral mucosa) were harvested and seeded onto AlloDerm® coated with human type IV collagen and cultured 11 days. EVPOMEs were imaged on the 11th day post-seeding using a scanning acoustic microscope (SAM) that consists of a single-element transducer: 61 MHz center frequency, 32 MHz bandwidth, 1.52 f-number. The specimen surface was determined by thresholding the magnitude of the signal at the first axial incidence of a value safely above noise: 20-40 dB above the signal for the water and 2-dimensional (2-D) ultrasonic images were created using confocal image reconstruction. A known area from each micrograph was divided into 12-40 even segments and examined for surface irregularities. These irregularities were quantified and one-way analysis of variance (ANOVA) and linear regression analysis were performed to correlate the surface profiles for both the AlloDerm® and EVPOME specimens imaged by SAM. Histology micrographs of the AlloDerm® and EVPOME specimens were also prepared and examined for surface irregularities. Unseeded AlloDerm® averaged seven to nine surface changes per 400 µm. The number of changes in surface irregularities decreased to two to three per 400 µm on the mature EVPOMEs. The numbers of surface irregularities between the unseeded AlloDerm® vs. developing EVPOME are similar for both histology and SAM 2-D B-scan images. For the EVPOME 2-D B-scan micrographs produced by SAM, the decrease in surface irregularities is indicative of the stratified epithelium formed by seeded oral keratinocytes; verified in the histology images between the AlloDerm® and EVPOME. A near 1:1 linear correlation shows the similarities between the two imaging modalities. SAM demonstrates its ability to discern the cell development and differentiation occurring on the EVPOME devices. Unlike histology, SAM measurements are noninvasive and can be used to monitor tissue graft development without damaging any cells/tissues.


Subject(s)
Keratinocytes/diagnostic imaging , Microscopy, Acoustic/methods , Mouth Mucosa/diagnostic imaging , Tissue Engineering/methods , Analysis of Variance , Cell Proliferation , Cells, Cultured , Collagen , Humans , Linear Models , Mouth Mucosa/cytology , Transducers
6.
Ann Biomed Eng ; 39(1): 44-52, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20924679

ABSTRACT

This study uses scanning acoustic microscopy (SAM) ultrasonic profilometry to determine acceptable vs. failed tissue engineered oral mucosa. Specifically, ex vivo-produced oral mucosal equivalents (EVPOMEs) under normal or thermally stressed culture conditions were scanned with the SAM operator blinded to the culture conditions. As seeded cells proliferate, they fill in and smooth out the surface irregularities; they then stratify and produce a keratinized protective upper layer. Some of these transformations could alter backscatter of ultrasonic signals and in the case of the thermally stressed cells, produce backscatter similar to an unseeded device. If non-invasive ultrasonic monitoring could be developed, then tissue cultivation could be adjusted to measure biological variations in the stratified surface. To create an EVPOME device, oral mucosa keratinocytes were seeded onto acellular cadaveric dermis. Two sets of EVPOMEs were cultured: one at physiological temperature 37 °C and the other at 43 °C. The specimens were imaged with SAM consisting of a single-element transducer: 61 MHz center frequency, 32 MHz bandwidth, 1.52 f#. Profilometry for the stressed and unseeded specimens showed higher surface irregularities compared to unstressed specimens. Elevated thermal stress retards cellular differentiation, increasing root mean square values; these results show that SAM can potentially monitor cell/tissue development.


Subject(s)
Cell Culture Techniques/methods , Keratinocytes/diagnostic imaging , Keratinocytes/physiology , Microscopy, Acoustic/methods , Mouth Mucosa/diagnostic imaging , Mouth Mucosa/growth & development , Tissue Engineering/methods , Cell Proliferation , Cells, Cultured , Humans , Keratinocytes/cytology , Mouth Mucosa/cytology , Organizations , Temperature
7.
Ultrasound Med Biol ; 37(1): 78-86, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21144960

ABSTRACT

Our recent studies have shown that high-intensity pulsed ultrasound can achieve mechanical tissue fragmentation, a process we call histotripsy. Histotripsy has many medical applications where noninvasive tissue removal or significant tissue disruption is needed (e.g., cancer therapy). The primary aim of this study is to investigate tissue regions treated by histotripsy and to characterize the boundary between the treated and untreated zones using transmission electron microscopy (TEM). The nature of the tissue disruption suggests many clinical applications and provides insights on the physical mechanism of histotripsy. Fresh ex vivo porcine kidney tissues were treated using histotripsy. A 1 MHz 100 mm diameter focused transducer was used to deliver 15 cycle histotripsy pulses at a peak negative pressure of 17 MPa and a pulse repetition frequency (PRF) of 100 Hz. Each lesion was produced by a 3 × 3 (lateral) × 4 (axial) grid with 2 mm between adjacent lateral and 3 mm between axial exposure points using mechanical scanning. Two thousand pulses were applied to each exposure point to achieve tissue fragmentation. After treatment, the tissue was processed and examined using TEM. Extensive fragmentation of the tissues treated with histotripsy was achieved. TEM micrographs of the tissue treated by histotripsy, showing no recognizable cellular features and little recognizable subcellular structures, demonstrates the efficacy of this technique in ablating the targeted tissue regions. A boundary, or transition zone, of a few microns separated the affected and unaffected areas, demonstrating the precision of histotripsy tissue targeting. TEM micrographs of the tissue treated by histotripsy showed no discernable cellular structure within the treated region. Histotripsy can minimize fragmentation of the adjoining nontargeted tissues because, as a nonlinear threshold phenomenon, damage can be highly localized. The potential for high lesion precision is evident in the TEM micrographs.


Subject(s)
High-Intensity Focused Ultrasound Ablation/methods , Kidney/ultrastructure , Analysis of Variance , Animals , In Vitro Techniques , Microscopy, Electron , Swine
8.
Article in English | MEDLINE | ID: mdl-22254305

ABSTRACT

Stress-strain curves of oral mucosal tissues were measured using direct mechanical testing. Measurements were conducted on both natural oral mucosal tissues and engineered devices, specifically a clinically developed ex vivo produced oral mucosal equivalent (EVPOME). As seeded cells proliferate on EVPOME devices, they produce a keratinized protective upper layer which fills in surface irregularities. These transformations can further alter stress-strain parameters as cells in EVPOME differentiate, more similar to natural oral mucosal tissues in contrast to an unseeded scaffold. In addition to tissue devices grown under normal conditions (37 °C), EVPOMEs were also produced at 43 °C. These thermally stressed specimens model possible failure mechanisms. Results from a mechanical deformation system capable of accurate measurements on small (approximately 1.0-1.5 cm(2)) cylindrical tissue samples are presented. Deformations are produced by lowering a circular piston, with a radius smaller than the sample radius, onto the center of the sample. Resulting force is measured with a precision electronic balance. Cultured EVPOME was less stiff than AlloDerm®, but similar to native porcine buccal tissue. Porcine skin and porcine palate tissues were even less stiff. Thermally stressed EVPOME was less stiff than normally cultured EVPOME as expected because stressed keratin cells were damaged reducing the structural integrity of the tissue.


Subject(s)
Models, Biological , Mucous Membrane/physiology , Skin Physiological Phenomena , Skin/cytology , Tissue Engineering/methods , Animals , Computer Simulation , Elastic Modulus , Mucous Membrane/cytology , Nonlinear Dynamics , Stress, Mechanical , Swine , Tensile Strength
9.
Article in English | MEDLINE | ID: mdl-19750596

ABSTRACT

Histotripsy is a well-controlled ultrasonic tissue ablation technology that mechanically and progressively fractionates tissue structures using cavitation. The fractionated tissue volume can be monitored with ultrasound imaging because a significant ultrasound backscatter reduction occurs.This paper correlates the ultrasound backscatter reduction with the degree of tissue fractionation characterized by the percentage of remaining normal-appearing cell nuclei on histology.Different degrees of tissue fractionation were generated in vitro in freshly excised porcine kidneys by varying the number of therapeutic ultrasound pulses from 100 to 2000 pulses per treatment location. All ultrasound pulses were 15 cycles at 1 MHz delivered at 100 Hz pulse repetition frequency and 19 MPa peak negative pressure. The results showed that the normalized backscatter intensity decreased exponentially with increasing number of pulses. Correspondingly, the percentage of normal appearing nuclei in the treated area decreased exponentially as well. A linear correlation existed between the normalized backscatter intensity and the percentage of normal appearing cell nuclei in the treated region. This suggests that the normalized backscatter intensity may be a potential quantitative real-time feedback parameter for histotripsy-induced tissue fractionation. This quantitative feedback may allow the prediction of local clinical outcomes, i.e., when a tissue volume has been sufficiently treated.


Subject(s)
Kidney Diseases/therapy , Kidney , Ultrasonic Therapy , Animals , Kidney/diagnostic imaging , Swine , Ultrasonography
10.
Ultrasound Med Biol ; 35(2): 245-55, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19027218

ABSTRACT

Extensive mechanical tissue fractionation can be achieved using successive high intensity ultrasound pulses ("histotripsy"). Histotripsy has many potential medical applications where noninvasive tissue removal is desired (e.g., tumor ablation). There is a concern that debris generated by histotripsy-induced tissue fractionation might be an embolization hazard. The aim of this study is to measure the size distribution of these tissue debris particles. Histotripsy pulses were produced by a 513-element 1 MHz array transducer, an 18-element 750 kHz array transducer and a 788 kHz single element transducer. Peak negative pressures of 11 to 25 MPa, pulse durations of 3 to 50 cycles, pulse repetition frequencies of 100 Hz to 2 kHz were used. Tissue debris particles created by histotripsy were collected and measured with a particle sizing system. In the resulting samples, debris <6 microm in diameter constituted >99% of the total number of tissue particles. The largest particle generated by one of the parameter sets tested was 54 microm in diameter, which is smaller than the clinic filter size (100 microm) used to prevent embolization. The largest particles generated using other parameter sets were larger than 60 microm but the value could not be specified using our current setup. Exposures with shorter pulses produced lower percentages of large tissue debris (>30 microm) in comparison to longer pulses. These results suggest that the tissue debris particle size distribution is adjustable by altering acoustic parameters if necessary.


Subject(s)
Endosonography/adverse effects , Lithotripsy/methods , Ultrasonic Therapy/adverse effects , Acoustics , Animals , Embolism/etiology , Endosonography/methods , Kidney/diagnostic imaging , Kidney/pathology , Liver/diagnostic imaging , Liver/pathology , Models, Animal , Particle Size , Risk , Swine , Ultrasonic Therapy/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...