Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 19(18)2019 Sep 18.
Article in English | MEDLINE | ID: mdl-31540412

ABSTRACT

The presence of heavy metal ions such as copper in the human body at certain concentrations and specific conditions can lead to the development of different diseases. The currently available analytical detection methods remain expensive, time-consuming, and often require sample pre-treatment. The development of specific and quantitative, easy-in-operation, and cost-effective devices, capable of monitoring the level of Cu2+ ions in environmental and physiological media, is necessary. We use silicon nanoribbon (SiNR) ion-sensitive field effect transistor (ISFET) devices modified with a Gly-Gly-His peptide for the detection of copper ions in a large concentration range. The specific binding of copper ions causes a conformational change of the ligand, and a deprotonation of secondary amine groups. By performing differential measurements, we gain a deeper insight into the details of the ion-ligand interaction. We highlight in particular the importance of considering non-specific interactions to explain the sensors' response.

2.
Anal Chem ; 89(21): 11325-11331, 2017 11 07.
Article in English | MEDLINE | ID: mdl-29039202

ABSTRACT

Silicon nanowire field effect transistors (NWFETs) are low noise, low power, ultrasensitive biosensors that are highly amenable to integration. However, using NWFETs to achieve direct protein detection in physiological buffers such as blood serum remains difficult due to Debye screening, nonspecific binding, and stringent functionalization requirements. In this work, we performed an indirect sandwich immunoassay in serum combined with exponential DNA amplification and pH measurement by ultrasensitive NWFET sensors. Measurements of model cytokine interleukin-2 concentrations from <20 fM to >200 pM were demonstrated, surpassing the conventional NWFET urease-based readout. Our approach paves way for future development of universal, highly sensitive, miniaturized, and integrated nanoelectronic devices that can be applied to a wide variety of analytes.


Subject(s)
Biosensing Techniques/methods , Electrochemical Techniques/methods , Immunoassay/methods , Interleukin-2/analysis , Nanowires/chemistry , Polymerase Chain Reaction/methods , Transistors, Electronic , Biomarkers/chemistry , Biosensing Techniques/instrumentation , Electrochemical Techniques/instrumentation , Humans , Hydrogen-Ion Concentration , Limit of Detection , Silicon/chemistry
3.
Biosens Bioelectron ; 87: 447-452, 2017 Jan 15.
Article in English | MEDLINE | ID: mdl-27591719

ABSTRACT

We report a method to suppress streaming potential using an Ag-coated microfluidic channel on a p-type silicon nanowire (SiNW) array measured by a multiplexed electrical readout. The metal layer sets a constant electrical potential along the microfluidic channel for a given reference electrode voltage regardless of the flow velocity. Without the Ag layer, the magnitude and sign of the surface potential change on the SiNW depends on the flow velocity, width of the microfluidic channel and the device's location inside the microfluidic channel with respect to the reference electrode. Noise analysis of the SiNW array with and without the Ag coating in the fluidic channel shows that noise frequency peaks, resulting from the operation of a piezoelectric micropump, are eliminated using the Ag layer with two reference electrodes located at inlet and outlet. This strategy presents a simple platform to eliminate the streaming potential and can become a powerful tool for nanoscale potentiometric biosensors.


Subject(s)
Biosensing Techniques/instrumentation , Microfluidic Analytical Techniques/instrumentation , Nanowires/chemistry , Silicon/chemistry , Silver/chemistry , Electric Conductivity , Electrodes , Equipment Design
4.
Biosensors (Basel) ; 6(2): 21, 2016 May 06.
Article in English | MEDLINE | ID: mdl-27164151

ABSTRACT

Ionic gradients play a crucial role in the physiology of the human body, ranging from metabolism in cells to muscle contractions or brain activities. To monitor these ions, inexpensive, label-free chemical sensing devices are needed. Field-effect transistors (FETs) based on silicon (Si) nanowires or nanoribbons (NRs) have a great potential as future biochemical sensors as they allow for the integration in microscopic devices at low production costs. Integrating NRs in dense arrays on a single chip expands the field of applications to implantable electrodes or multifunctional chemical sensing platforms. Ideally, such a platform is capable of detecting numerous species in a complex analyte. Here, we demonstrate the basis for simultaneous sodium and fluoride ion detection with a single sensor chip consisting of arrays of gold-coated SiNR FETs. A microfluidic system with individual channels allows modifying the NR surfaces with self-assembled monolayers of two types of ion receptors sensitive to sodium and fluoride ions. The functionalization procedure results in a differential setup having active fluoride- and sodium-sensitive NRs together with bare gold control NRs on the same chip. Comparing functionalized NRs with control NRs allows the compensation of non-specific contributions from changes in the background electrolyte concentration and reveals the response to the targeted species.


Subject(s)
Biosensing Techniques , Ions , Nanowires , Silicon , Transistors, Electronic , Biosensing Techniques/instrumentation , Ions/chemistry , Nanowires/chemistry , Silicon/chemistry
5.
ACS Nano ; 9(5): 4872-81, 2015 May 26.
Article in English | MEDLINE | ID: mdl-25817336

ABSTRACT

Field-effect transistors (FETs) form an established technology for sensing applications. However, recent advancements and use of high-performance multigate metal-oxide semiconductor FETs (double-gate, FinFET, trigate, gate-all-around) in computing technology, instead of bulk MOSFETs, raise new opportunities and questions about the most suitable device architectures for sensing integrated circuits. In this work, we propose pH and ion sensors exploiting FinFETs fabricated on bulk silicon by a fully CMOS compatible approach, as an alternative to the widely investigated silicon nanowires on silicon-on-insulator substrates. We also provide an analytical insight of the concept of sensitivity for the electronic integration of sensors. N-channel fully depleted FinFETs with critical dimensions on the order of 20 nm and HfO2 as a high-k gate insulator have been developed and characterized, showing excellent electrical properties, subthreshold swing, SS ∼ 70 mV/dec, and on-to-off current ratio, Ion/Ioff ∼ 10(6), at room temperature. The same FinFET architecture is validated as a highly sensitive, stable, and reproducible pH sensor. An intrinsic sensitivity close to the Nernst limit, S = 57 mV/pH, is achieved. The pH response in terms of output current reaches Sout = 60%. Long-term measurements have been performed over 4.5 days with a resulting drift in time δVth/δt = 0.10 mV/h. Finally, we show the capability to reproduce experimental data with an extended three-dimensional commercial finite element analysis simulator, in both dry and wet environments, which is useful for future advanced sensor design and optimization.

6.
ACS Nano ; 7(7): 5978-83, 2013 Jul 23.
Article in English | MEDLINE | ID: mdl-23768238

ABSTRACT

Ion-sensitive field-effect transistors based on silicon nanowires with high dielectric constant gate oxide layers (e.g., Al2O3 or HfO2) display hydroxyl groups which are known to be sensitive to pH variations but also to other ions present in the electrolyte at high concentration. This intrinsically nonselective sensitivity of the oxide surface greatly complicates the selective sensing of ionic species other than protons. Here, we modify individual nanowires with thin gold films as a novel approach to surface functionalization for the detection of specific analytes. We demonstrate sodium ion (Na(+)) sensing by a self-assembled monolayer (SAM) of thiol-modified crown ethers in a differential measurement setup. A selective Na(+) response of ≈-44 mV per decade in a NaCl solution is achieved and tested in the presence of protons (H(+)), potassium (K(+)), and chloride (Cl(-)) ions, by measuring the difference between a nanowire with a gold surface functionalized by the SAM (active) and a nanowire with a bare gold surface (control). We find that the functional SAM does not affect the unspecific response of gold to pH and background ionic species. This represents a clear advantage of gold compared to oxide surfaces and makes it an ideal candidate for differential measurements.


Subject(s)
Conductometry/instrumentation , Electrodes , Gold/chemistry , Nanowires/chemistry , Silicon/chemistry , Sodium/analysis , Transistors, Electronic , Adsorption , Equipment Design , Equipment Failure Analysis , Sodium/chemistry
7.
ACS Nano ; 6(10): 9291-8, 2012 Oct 23.
Article in English | MEDLINE | ID: mdl-23016890

ABSTRACT

Silicon nanowire field-effect transistors have attracted substantial interest for various biochemical sensing applications, yet there remains uncertainty concerning their response to changes in the supporting electrolyte concentration. In this study, we use silicon nanowires coated with highly pH-sensitive hafnium oxide (HfO(2)) and aluminum oxide (Al(2)O(3)) to determine their response to variations in KCl concentration at several constant pH values. We observe a nonlinear sensor response as a function of ionic strength, which is independent of the pH value. Our results suggest that the signal is caused by the adsorption of anions (Cl(-)) rather than cations (K(+)) on both oxide surfaces. By comparing the data to three well-established models, we have found that none of those can explain the present data set. Finally, we propose a new model which gives excellent quantitative agreement with the data.


Subject(s)
Biosensing Techniques/instrumentation , Electrolytes/chemistry , Metal Nanoparticles/chemistry , Models, Chemical , Silicon/chemistry , Transistors, Electronic , Computer Simulation , Equipment Design , Equipment Failure Analysis , Metal Nanoparticles/ultrastructure
SELECTION OF CITATIONS
SEARCH DETAIL
...