1.
Diagn Pathol ; 8: 48, 2013 Mar 25.
Article in English | MEDLINE | ID: mdl-23531405

ABSTRACT

The comparative study of the results of various segmentation methods for the digital images of the follicular lymphoma cancer tissue section is described in this paper. The sensitivity and specificity and some other parameters of the following adaptive threshold methods of segmentation: the Niblack method, the Sauvola method, the White method, the Bernsen method, the Yasuda method and the Palumbo method, are calculated. Methods are applied to three types of images constructed by extraction of the brown colour information from the artificial images synthesized based on counterpart experimentally captured images. This paper presents usefulness of the microscopic image synthesis method in evaluation as well as comparison of the image processing results. The results of thoughtful analysis of broad range of adaptive threshold methods applied to: (1) the blue channel of RGB, (2) the brown colour extracted by deconvolution and (3) the 'brown component' extracted from RGB allows to select some pairs: method and type of image for which this method is most efficient considering various criteria e.g. accuracy and precision in area detection or accuracy in number of objects detection and so on. The comparison shows that the White, the Bernsen and the Sauvola methods results are better than the results of the rest of the methods for all types of monochromatic images. All three methods segments the immunopositive nuclei with the mean accuracy of 0.9952, 0.9942 and 0.9944 respectively, when treated totally. However the best results are achieved for monochromatic image in which intensity shows brown colour map constructed by colour deconvolution algorithm. The specificity in the cases of the Bernsen and the White methods is 1 and sensitivities are: 0.74 for White and 0.91 for Bernsen methods while the Sauvola method achieves sensitivity value of 0.74 and the specificity value of 0.99. According to Bland-Altman plot the Sauvola method selected objects are segmented without undercutting the area for true positive objects but with extra false positive objects. The Sauvola and the Bernsen methods gives complementary results what will be exploited when the new method of virtual tissue slides segmentation be develop. VIRTUAL SLIDES: The virtual slides for this article can be found here: slide 1: http://diagnosticpathology.slidepath.com/dih/webViewer.php?snapshotId=13617947952577 and slide 2: http://diagnosticpathology.slidepath.com/dih/webViewer.php?snapshotId=13617948230017.


Subject(s)
3,3'-Diaminobenzidine , Hematoxylin , Image Interpretation, Computer-Assisted , Lymphoma, Follicular/diagnosis , Staining and Labeling , Algorithms , Humans , Image Interpretation, Computer-Assisted/methods , Limit of Detection , Pattern Recognition, Automated/methods , Staining and Labeling/methods
2.
Virchows Arch ; 458(2): 237-45, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21085985

ABSTRACT

The Joint Photographic Experts Group (JPEG) standard format is one of the most widely used in image compression technologies. More recently, JPEG2000 format has emerged as a state-of-the-art technology that provides substantial improvements in picture quality at higher compression ratios. However, there has been no attempt to date to determine which of the two compression formats produces less variability in the automated evaluation of immunohistochemically stained digital images in agreement with their compression rates and complexity degrees. The evaluation of Ki67 and FOXP3 immunohistochemical nuclear markers was performed in a total of 329 digital images: 47 were captured in uncompressed Tagged Image File Format (TIFF), 141 were converted to three JPEG compressed formats (47 each with 1:3, 1:23 and 1:46 compression) and 141 were converted to three JPEG2000 compressed formats (47 each with 1:3, 1:23 and 1:46 compression). The count differences between images in TIFF versus JPEG formats were compared with those obtained between images in TIFF versus JPEG2000 formats at the three levels of compression. It was found that, using JPEG2000 compression, the results of the stained nuclei count are close enough to the results obtained with uncompressed images, especially in highly complex images at minimum and medium compression. Otherwise, in images of low complexity, JPEG and JPEG2000 had similar count efficiency to that of the original TIFF images at all compression levels. These data suggest that JPEG2000 could give rise to an efficient means of storage, reducing file size and storage capacity, without compromise on the immunohistochemical analytical quality.


Subject(s)
Cell Nucleus , Data Compression/methods , Image Interpretation, Computer-Assisted/methods , Automation , Humans , Immunohistochemistry/methods , Staining and Labeling