Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Ultraschall Med ; 34(1): 51-7, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22872379

ABSTRACT

PURPOSE: Transtemporal sonothrombolysis is a tool for a more effective treatment in acute stroke patients. However, some reports revealed side effects, which might be potentially connected to temperature elevation. To gain better insight into cerebral temperature changes during transtemporal sonication, diagnostic and therapeutic ultrasound (US) applications were evaluated using an anthropomorphic skull model. MATERIALS AND METHODS: The impact of diagnostic (PW-Doppler, 1.8-MHz, 0.11 W/cm², TIC 1.2) and therapeutic (1-MHz and 3-MHz, 0.07 - 0.71 W/cm², continuous and pulsed mode) US application on temperature changes was evaluated at the level of muscle/temporal bone (TB), TB/brain, brain and at the middle cerebral artery (MCA) using 4 miniature thermocouples along the US beam. Sonication lasted 120 minutes. RESULTS: Diagnostic ultrasound revealed a maximum temperature increase of 1.45°/0.60°/0.39°/0.41°C (muscle/TB, TB/brain, brain, MCA) after 120 minutes. Therapeutic-1-MHz ultrasound raised temperature by 4.33°/2.02°/1.05 °C/0.81°C (pulsed 1:20) and by 10.38°/4.95°/2.43°/2.08°C (pulsed 1:5) over 120 minutes. Therapeutic-3-MHz US raised temperature by 4.89°/2.56°/1.24/1.25°C (pulsed 1:20) and by 14.77°/6.59°/3.56°/2.86°C (pulsed 1:5) over 120 minutes, respectively. Continuous application of therapeutic US (1-MHz and 3-MHz) led to a temperature increase of 13.86°/3.63°/1.66°/1.48°C and 17.09°/4.28°/1.38/0.99°C within 3 minutes. CONCLUSION: Diagnostic PW-Doppler showed only a moderate temperature increase and can be considered as safe. Therapeutic sonication is very powerful in delivering energy so that even pulsed application modes resulted in significant and potentially harmful temperature increases.


Subject(s)
Body Temperature Regulation/physiology , Brain/physiopathology , Cerebral Infarction/diagnostic imaging , Cerebral Infarction/therapy , Heating/adverse effects , Intracranial Thrombosis/diagnostic imaging , Intracranial Thrombosis/therapy , Mechanical Thrombolysis/adverse effects , Mechanical Thrombolysis/methods , Phantoms, Imaging , Ultrasonic Therapy/adverse effects , Ultrasonic Therapy/methods , Ultrasonography, Doppler, Transcranial/adverse effects , Ultrasonography, Doppler, Transcranial/methods , Humans , In Vitro Techniques , Mechanical Thrombolysis/instrumentation , Transducers , Ultrasonic Therapy/instrumentation , Ultrasonography, Doppler, Transcranial/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...