Ann Biomed Eng ; 49(12): 3165-3175, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34431015

ABSTRACT

Despite improved hemocompatibility of left-ventricular assist devices (LVADs), assessment of blood damage remains mandatory in preclinical testing as standardized by ASTM-F1841. The most relevant test fluid is fresh, non-pooled human blood, but the limited volume of a standard donation requires significantly smaller loops than those commonly used with animal blood. In a recent study with porcine blood, we verified a miniaturized test loop with only 160 mL for the ASTM-conform paired testing of at least two LVADs and a static reference. Here, we validated this mini test loop for standardized assessment of blood damage with one 450-mL single donation of fresh human blood. Blood damage was assessed for HeartMate 3 and BPX-80 in 9 experiments with heparinized human blood for 6 hours. We analyzed plasma free hemoglobin, von Willebrand factor (vWF) concentration and collagen-binding functionality and calculated indices of hemolysis and vWF-ratios. Overall, we observed less blood damage compared to our previous study; however, the differences in mean indices of hemolysis and in mean normalized vWF-ratio between BPX-80 and HeartMate 3 were consistent for human blood. Thus, our mini test loop proved to be valid for preclinical standardized assessment of blood damage with only 450 mL of fresh human blood.


Subject(s)
Heart-Assist Devices/adverse effects , Hemolysis , Animals , Humans , Materials Testing , Miniaturization , Swine
2.
Artif Organs ; 44(4): 419-427, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31660616

ABSTRACT

Passively levitated ventricular assist devices (VADs) are vulnerable to impeller-housing contact and could benefit from surface coatings that improve wear resistance. Such coatings can be manufactured by plasma electrolytic oxidation (PEO), but their suitability for blood-contact applications needs further investigation. We therefore compared blood-surface interactions of polished titanium grade 5 (Ti Gr 5), as a general VAD reference material, uncoated ground titanium grade 4 (Ti Gr 4) and two commercially available PEO coatings on Ti Gr 4. In n = 4 static platelet adhesion tests, material samples were incubated with platelet-rich plasma (PRP) and consecutively analyzed for adhesive platelets by immunofluorescence microscopy. Additionally, PRP supernatant of incubated material samples was analyzed for changes in antithrombin III and fibrinogen concentrations by turbodimetry and enzyme-linked immunosorbent assay, respectively. We could not find any significant differences between the materials in the analyzed hemocompatibility markers (P > .05). Thus, we conclude that PEO coatings might offer a similar hemocompatibility to that of polished Ti Gr 5 and uncoated Ti Gr 4. Nevertheless, future studies should investigate blood-surface interactions of PEO coatings under realistic VAD-related flow conditions to better evaluate their potential for VAD applications.


Subject(s)
Blood Coagulation , Ceramics , Heart-Assist Devices , Platelet Adhesiveness , Titanium , Electrochemical Techniques , Feasibility Studies , Humans , Materials Testing
3.
Ann Biomed Eng ; 48(2): 768-779, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31724071

ABSTRACT

Although the hemocompatibility of left-ventricular assist devices (LVADs) has continuously improved, assessment of hemolysis remains mandatory in pre-clinical testing. The ASTM-F1841 has standardized this assessment since 1997. However, the recommended usage of fresh, non-pooled human blood is hardly feasible with the test loop volume specified therein, when testing the device under test versus a predicate device as required by the international standard 10993-4. In this study, we compared ASTM-conforming (ASTM) and downscaled (mini) test loops with a one-third priming volume for the assessment of blood damage at the ASTM operating point. Blood damage was assessed for HeartMate 3 and BPX-80 in 6 experiments with heparinized porcine slaughterhouse blood for 6 h. We analyzed plasma free hemoglobin (pfHb), von Willebrand factor (vWF) concentration and collagen-binding functionality and calculated indices of hemolysis and vWF-ratios. The mini test loops provided significantly higher pfHb increase and consistently stronger vWF-ratio decrease and yielded a significantly better differentiation of the pumps. Interestingly, indices of hemolysis were generally lower in the mini set-up, indicating less adverse effects by the mini loop itself. Thus, we propose our mini test loop as suitable tool for clinically relevant standardized assessment of blood damage by future LVADs with single-donation human blood.


Subject(s)
Heart-Assist Devices , Materials Testing , Animals , Hemoglobins/metabolism , Hemolysis , Humans , Swine , von Willebrand Factor/metabolism
4.
PLoS One ; 12(2): e0171029, 2017.
Article in English | MEDLINE | ID: mdl-28234916

ABSTRACT

OBJECTIVES: Acquired von Willebrand syndrome (AvWS) is associated with postoperative bleeding complications in patients with continuous flow left ventricular assist devices (CF-LVADs). The aim of this study is to analyze the perioperative vWF profile comparing an axial pump (HMII) to a centrifugal pump (HVAD) regarding the correlation between perioperative occurrence of AvWS, early- and late-postoperative bleeding events. METHODS: From July 2013 until March 2015 blood samples of 33 patients (12 HMII/ 8 HVAD/ 13 controls) were prospectively collected at 12 different time points and analyzed for the vWF antigen (vWF:Ag), its activity (vWF:Ac) and the vWF:Ac/vWF:Ag-ratio (vWF:ratio). The follow up period for postoperative bleeding events was from July 2013 until July 2016. RESULTS: Postoperatively, there was no difference in the vWF-profile between HVAD and HMII groups. However, a subgroup of patients already had significantly lower vWF:ratios preoperatively. Postoperatively, both CF-LVAD groups presented significantly lower vWF:ratios compared to the control group. Bleeding events per patient-year did not differ between the two groups (HMII vs. HVAD: 0.67 vs. 0.85, p = 0.685). We detected a correlation between vWF:ratio <0.7at LVAD-start (r = -0.583, p = 0.006) or at the end of surgery (r = -0.461, p = 0.035) and the occurrence of pericardial tamponade. In the control group, the drop in both vWF:Ag and vWF:Ac recovered immediately postoperatively above preoperative values. CONCLUSION: A subgroup of patients with end-stage heart failure already suffers AvWS preoperatively. In both CF-LVAD groups, AvWS begins immediately after surgery. Intraoperative vWF:ratios <0.7 correlate with higher incidences of pericardial tamponade and re-operation. The presumably dilutive effect of the heart lung machine on vWF vanishes immediately at the end of surgery, possibly as part of an acute-phase response.


Subject(s)
Coronary Artery Bypass/adverse effects , Heart Failure/blood , Postoperative Hemorrhage/blood , von Willebrand Diseases/blood , von Willebrand Factor/metabolism , Aged , Antigens/blood , Antigens/immunology , Female , Heart Failure/physiopathology , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Humans , Male , Middle Aged , Perioperative Period/adverse effects , Postoperative Hemorrhage/etiology , Postoperative Hemorrhage/physiopathology , von Willebrand Diseases/etiology , von Willebrand Diseases/immunology , von Willebrand Diseases/physiopathology , von Willebrand Factor/immunology