Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Radiat Biol ; 91(8): 643-52, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25968557

ABSTRACT

PURPOSE: In line with the long-term aim of establishing the laser-based particle acceleration for future medical application, the radiobiological consequences of the typical ultra-short pulses and ultra-high pulse dose rate can be investigated with electron delivery. MATERIALS AND METHODS: The radiation source ELBE (Electron Linac for beams with high Brilliance and low Emittance) was used to mimic the quasi-continuous electron beam of a clinical linear accelerator (LINAC) for comparison with electron pulses at the ultra-high pulse dose rate of 10(10) Gy min(-1) either at the low frequency of a laser accelerator or at 13 MHz avoiding effects of prolonged dose delivery. The impact of pulse structure was analyzed by clonogenic survival assay and by the number of residual DNA double-strand breaks remaining 24 h after irradiation of two human squamous cell carcinoma lines of differing radiosensitivity. RESULTS: The radiation response of both cell lines was found to be independent from electron pulse structure for the two endpoints under investigation. CONCLUSIONS: The results reveal, that ultra-high pulse dose rates of 10(10) Gy min(-1) and the low repetition rate of laser accelerated electrons have no statistically significant influence (within the 95% confidence intervals) on the radiobiological effectiveness of megavoltage electrons.


Subject(s)
Carcinoma, Squamous Cell/pathology , Carcinoma, Squamous Cell/physiopathology , Electrons , Apoptosis/radiation effects , Cell Line, Tumor , Cell Survival/radiation effects , Dose-Response Relationship, Radiation , Humans , Radiation Dosage , Radiation Tolerance/radiation effects
2.
Radiat Environ Biophys ; 54(2): 155-66, 2015 May.
Article in English | MEDLINE | ID: mdl-25600561

ABSTRACT

The long-term goal to integrate laser-based particle accelerators into radiotherapy clinics not only requires technological development of high-intensity lasers and new techniques for beam detection and dose delivery, but also characterization of the biological consequences of this new particle beam quality, i.e. ultra-short, ultra-intense pulses. In the present work, we describe successful in vivo experiments with laser-driven electron pulses by utilization of a small tumour model on the mouse ear for the human squamous cell carcinoma model FaDu. The already established in vitro irradiation technology at the laser system JETI was further enhanced for 3D tumour irradiation in vivo in terms of beam transport, beam monitoring, dose delivery and dosimetry in order to precisely apply a prescribed dose to each tumour in full-scale radiobiological experiments. Tumour growth delay was determined after irradiation with doses of 3 and 6 Gy by laser-accelerated electrons. Reference irradiation was performed with continuous electron beams at a clinical linear accelerator in order to both validate the dedicated dosimetry employed for laser-accelerated JETI electrons and above all review the biological results. No significant difference in radiation-induced tumour growth delay was revealed for the two investigated electron beams. These data provide evidence that the ultra-high dose rate generated by laser acceleration does not impact the biological effectiveness of the particles.


Subject(s)
Electrons/therapeutic use , Lasers , Particle Accelerators , Radiotherapy/instrumentation , Animals , Carcinoma, Squamous Cell/pathology , Carcinoma, Squamous Cell/radiotherapy , Cell Line, Tumor , Cell Proliferation/radiation effects , Cell Transformation, Neoplastic , Dose-Response Relationship, Radiation , Female , Humans , Male , Mice , Radiometry
3.
Med Phys ; 36(12): 5506-14, 2009 Dec.
Article in English | MEDLINE | ID: mdl-20095263

ABSTRACT

PURPOSE: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic EBT-1, when scanned with a flatbed scanner for film readout. METHODS: Dose response curves were determined for 12 different beam qualities ranging from a 10 kVp x-ray beam to a 15 MVp x-ray beam and include also two high energy electron beam qualities (6 and 18 MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6 MVp). RESULTS: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the 25 kVp and 6 MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5 Gy relative to the normalized netOD for 10 Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependence for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. CONCLUSIONS: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.


Subject(s)
Electrons , Photons , Radiometry/instrumentation , Calibration , Radiation Dosage
4.
Med Phys ; 36(12): 5506-5514, 2009 Dec.
Article in English | MEDLINE | ID: mdl-28524999

ABSTRACT

PURPOSE: The aim of this article is to investigate the energy dependence of the radiochromic film type, Gafchromic™ EBT-1, when scanned with a flatbed scanner for film readout. METHODS: Dose response curves were determined for 12 different beam qualities ranging from a10kVp x-ray beam to a 15MVp x-ray beam and include also two high energy electron beam qualities (6 and 18MeV). The dose responses measured as net optical density (netOD) for the different beam qualities were normalized to the response of a reference beam quality (6MVp). RESULTS: A strong systematic energy dependence of the film response was found. The lower the effective beam energy, the less sensitive the EBT-1 films get. The maximum decrease in dose for the same film response between the25kVp and 6MVp beam qualities was 44%. Additionally, a difference in energy dependence for different doses was discovered, meaning that higher doses show a smaller dependency on energy than lower doses. The maximum decrease in the normalized netOD was found to be 25% for a dose of 0.5Gy relative to the normalized netOD for 10Gy. Moreover, a scaling procedure is introduced, allowing the correction of the energy dependence for the investigated beam qualities and also for comparable x-ray beam qualities within the energy range studied. CONCLUSIONS: A strong energy dependence for EBT-1 radiochromic films was found. The films were readout with a flatbed scanner. If the effective beam energy is known, the energy dependence can be corrected with the introduced scaling procedure. Further investigation of the influence of the spectral band of the readout device on energy dependence is needed to understand the reason for the different energy dependences found in this and previous works.

SELECTION OF CITATIONS
SEARCH DETAIL
...