1.
Artif Organs ; 38(4): 346-52, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24102380

ABSTRACT

Proper wound healing can be assessed by monitoring the wound surface area. Its reduction by 10 or 50% should be achieved after 1 or 4 weeks, respectively, from the start of the applied therapy. There are various methods of wound area measurement, which differ in terms of the cost of the devices and their accuracy. This article presents an originally developed method for wound area measurement. It is based on the automatic recognition of the wound contour with a software application running on a smartphone. The wound boundaries have to be traced manually on transparent foil placed over the wound. After taking a picture of the wound outline over a grid of 1 × 1 cm, the AreaMe software calculates the wound area, sends the data to a clinical database using an Internet connection, and creates a graph of the wound area change over time. The accuracy and precision of the new method was assessed and compared with the accuracy and precision of commercial devices: Visitrak and SilhouetteMobile. The comparison was performed using 108 wound shapes that were measured five times with each device, using an optical scanner as a reference device. The accuracy of the new method was evaluated by calculating relative errors and comparing them with relative errors for the Visitrak and the SilhouetteMobile devices. The precision of the new method was determined by calculating the coefficients of variation and comparing them with the coefficients of variation for the Visitrak and the SilhouetteMobile devices. A statistical analysis revealed that the new method was more accurate and more precise than the Visitrak device but less accurate and less precise than the SilhouetteMobile device. Thus, the AreaMe application is a superior alternative to the Visitrak device because it provides not only a more accurate measurement of the wound area but also stores the data for future use by the physician.


Subject(s)
Cell Phone , Diabetic Foot/diagnosis , Software , Wound Healing/physiology , Diabetic Foot/physiopathology , Humans
2.
Int J Artif Organs ; 36(12): 869-77, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24362895

ABSTRACT

PURPOSE: The objective was to assess glucose, lactate, glycerol, and pyruvate concentrations in the interstitial fluid of the adipose tissue as well as the glucose relative recovery coefficient in reference to capillary blood (RC) during the first two days of the standard treatment of diabetic ketoacidosis (DKA) in patients with type 1 and type 2 diabetes. MATERIALS AND METHODS: The study group consisted of 19 patients (12 with type 1 diabetes and 7 with type 2 diabetes). The metabolic state of the patients was monitored using the microdialysis technique. The analysis of variance was used to investigate whether the type of diabetes and the duration of treatment influenced the assessed parameters. RESULTS: Concentrations of all the monitored components were stable after the initial 12 h of treatment. Glucose concentration was higher and concentrations of all the other components were lower (p<0.0001) in patients with type 1 diabetes than in patients with type 2 diabetes. Significantly higher RC was observed in patients with type 1 diabetes during the initial 12 h. CONCLUSIONS: The results suggest that the standard treatment of DKA is effective in stabilizing a concentration of the studied metabolic components in the interstitial fluid in patients with type 1 and type 2 diabetes despite differences in the glucose concentration at the beginning of the treatment.


Subject(s)
Adipose Tissue/metabolism , Blood Glucose/metabolism , Diabetic Ketoacidosis/metabolism , Extracellular Fluid/metabolism , Glycerol/metabolism , Lactic Acid/metabolism , Microdialysis , Pyruvic Acid/metabolism , Adult , Aged , Biomarkers/metabolism , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 1/complications , Diabetes Mellitus, Type 2/blood , Diabetes Mellitus, Type 2/complications , Diabetic Ketoacidosis/blood , Diabetic Ketoacidosis/diagnosis , Diabetic Ketoacidosis/etiology , Diabetic Ketoacidosis/therapy , Female , Humans , Male , Middle Aged , Time Factors , Young Adult
3.
Diabetes Technol Ther ; 15(8): 712-21, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23902402

ABSTRACT

AIM: The present study assesses precision and accuracy of four selected methods of wound area measurements in diabetic foot wounds. MATERIALS AND METHODS: The areas of 16 wound shapes were measured using linear measurement with elliptical estimation (Elliptical method), using the Visitrak™ (Smith & Nephew, London, United Kingdom) device, the SilhouetteMobile™ device (ARANZ Medical Ltd., Christchurch, New Zealand), and the TeleDiaFoS system (Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland). The actual area of a wound shape was determined with a tested scanner and specifically developed software. Accuracy of the area measurement method was assessed by the relative error (RE), whereas precision was assessed by the coefficient of variation (CV). RESULTS: The overall absolute REs were 13.3%, 6.8%, 2.1%, and 2.3% for the Elliptical method, the Visitrak device, the TeleDiaFoS system, and the SilhouetteMobile device, respectively. The accuracy of the Visitrak device was remarkably reduced for wound areas smaller than 2 cm². The overall CVs were 6.0%, 6.3%, 1.6%, and 3.1% for the Elliptical method, the Visitrak device, the TeleDiaFoS system, and the SilhouetteMobile device, respectively. The precision of the Visitrak device was revealed to be remarkably lower for small wounds (<2 cm²). CONCLUSIONS: The Elliptical method gives overestimation up to 33%; thus, it should not be used in applications where the actual wound area is an important parameter (like the prediction of wound healing). The TeleDiaFoS system and the SilhouetteMobile device showed the best accuracy of all used methods; however, the precision of the TeleDiaFoS system was revealed to be higher than the precision of the SilhouetteMobile device. The accuracy and the precision of the Visitrak device are significantly reduced for wounds smaller than 2 cm².


Subject(s)
Diabetic Foot/pathology , Diagnostic Imaging/instrumentation , Skin/pathology , Diabetic Foot/physiopathology , Dimensional Measurement Accuracy , Humans , Image Processing, Computer-Assisted , Materials Testing , Models, Biological , Photography , Poland , Severity of Illness Index , Surface Properties
4.
Ann Biomed Eng ; 39(11): 2721-34, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21796500

ABSTRACT

The objectives were as follows: (1) estimating mean value of the overall hemoglobin glycation rate constant (k); (2) analyzing inter-individual variability of k; (3) verifying ability of the hemoglobin A1c (HbA1c) formation model to predict changes of HbA1c during red blood cells cultivation in vitro and to reproduce the clinical data. The mean k estimated in a group of 10 non-diabetic subjects was equal to 1.257 ± 0.114 × 10(-9) L mmol(-1) s(-1). The mean k was not affected by a way of estimation of glycemia. The mean k differed less than 20% from values reported earlier and it was almost identical to the mean values calculated on basis of the selected published data. Analysis of variability of k suggests that inter-individual heterogeneity of HbA1c formation is limited or rare. The HbA1c mathematical model was able to predict changes of HbA1c in vitro resulting from different glucose levels and to reproduce a linear relationship of HbA1c and average glucose obtained in the A1C-Derived Average Glucose Study. This study demonstrates that the glycation model with the same k value might be used in majority of individuals as a tool supporting interpretation of HbA1c in different clinical situations.


Subject(s)
Blood Glucose , Glycated Hemoglobin , Models, Theoretical , Adult , Aged , Algorithms , Analysis of Variance , Blood Glucose/analysis , Blood Glucose/metabolism , Case-Control Studies , Diabetes Mellitus/metabolism , Erythrocytes/chemistry , Female , Glycated Hemoglobin/analysis , Glycated Hemoglobin/metabolism , Humans , Male , Middle Aged
5.
Artif Organs ; 35(2): 176-82, 2011 Feb.
Article in English | MEDLINE | ID: mdl-20946304

ABSTRACT

Diabetic foot syndrome (DFS) is one of the major complications of diabetes, and it can lead to foot amputations. It is very important to assure good medical care for diabetic patients not only during their stay at hospital but also at home. Telecare can be one good solution for extending medical care to patients' homes. There are some reports regarding the application of new technologies in this field. The standard current model of telecare of DFS includes experts at hospital who conduct clinical examinations and decision making at a distance, in close cooperation with a visiting nurse and the patient. In the present paper a new paradigm of the DFS's telecare is introduced, which eliminates the visiting nurse. The designed and developed TeleDiaFoS system consists of a traditional database and mobile patient's module (PM) allowing for documentation of the foot images as well as the results of blood glucose and blood pressure measurements taken by the patient himself at home. A 2-year validation of the TeleDiaFoS system on 10 DFS patients (3 months each) proved its usefulness and led to acceptance of this type of technical support by patients and physicians. The designed and developed system and proposed sterilization procedure of the PM have been found to be easy to use by the patient at home.


Subject(s)
Diabetic Foot/diagnosis , Telemedicine/instrumentation , Aged , Diabetic Foot/therapy , Equipment Design , Foot/pathology , Home Care Services/trends , Humans , Middle Aged , Telemedicine/trends
6.
Ann Biomed Eng ; 36(7): 1188-202, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18449641

ABSTRACT

Glycated hemoglobin A1c (HbA1c) concentration in blood is an index of the glycemic control widely used in diabetology. The aim of the work was to validate two mathematical models of HbA1c formation (assuming irreversible or reversible glycation, respectively) and select a model, which was able to predict changes of HbA1c concentration in response to varying glycemia courses with higher accuracy. The experimental procedure applied consisted of an original combination of: in vivo continuous glucose concentration monitoring, long-term in vitro culturing of the human erythrocytes and mathematical modeling of HbA1c formation in vivo and in vitro with HbA1c values scaled according to the most specific analytical methods. Sixteen experiments were conducted in vitro using blood samples collected from healthy volunteer and stable type 1 diabetic patients whose glycemia was estimated beforehand based on long-term monitoring. The mean absolute difference of the measured and predicted HbA1c concentrations for the in vitro experiments were equal to 0.64 +/- 0.29% and 1.42 +/- 0.16% (p = 0.0007) for irreversible and for reversible model, respectively, meaning that the irreversible model was able to predict the glycation kinetics with a higher accuracy. This model was also more sensitive to a deviation of the erythrocytes life span.


Subject(s)
Blood Chemical Analysis/methods , Diabetes Mellitus/blood , Diabetes Mellitus/diagnosis , Erythrocytes/metabolism , Glycated Hemoglobin/analysis , Glycemic Index , Models, Cardiovascular , Adult , Cells, Cultured , Computer Simulation , Diabetes Mellitus/pathology , Diagnosis, Computer-Assisted/methods , Female , Humans , Male , Monitoring, Physiologic/methods
7.
Artif Organs ; 32(1): 45-51, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18181802

ABSTRACT

The objective of the study was to establish the quasi-continuous courses, using microdialysis technique, of glucose, lactate, and glycerol concentrations in interstitial fluid of abdominal adipose tissue during the standard treatment of acute diabetes complications. Clinical studies were carried out on 31 diabetic patients during the initial 48 h of the treatment. In all but two obese female patients with hyperglycemic hyperosmolar state (HHS) did glucose concentration in perfusion fluid (PF) reflect concentration in capillary blood. The recovery of glucose correlated with patients' body mass index (r = 0.55). It was significantly higher in lean and overweight patients (91 +/- 15%) than in obese patients (55 +/- 31%). The course of lactate concentration in PF coincided with the course in venous blood (2.1 +/- 0.3 mmol/L vs. 2.0 +/- 0.5 mmol/L, P = 0.35). Glycerol concentration was 267 +/- 41 micromol/L and 133 +/- 40 micromol/L in PF and venous blood, respectively (P = 0.004). The study indicated that microdialysis may be an effective tool to monitor concentration of different metabolites in interstitial fluid of the adipose tissue during treatment of the acute complications of diabetes. Applicability of the technique in the monitoring of HHS, especially in obese female patients, needs further investigation.


Subject(s)
Diabetes Mellitus, Type 1/complications , Diabetes Mellitus, Type 2/complications , Glucose/metabolism , Glycerol/metabolism , Hyperglycemia/metabolism , Lactic Acid/metabolism , Microdialysis , Abdominal Fat/metabolism , Adult , Aged , Aged, 80 and over , Extracellular Fluid/metabolism , Female , Humans , Hyperglycemia/etiology , Middle Aged
8.
J Telemed Telecare ; 13(1): 44-7, 2007.
Article in English | MEDLINE | ID: mdl-17288659

ABSTRACT

We examined the influence of the increased frequency of data reporting on metabolic control in patients with diabetes. Data reporting was via a home telecare system that stored blood glucose values and was integrated with a simple electronic logbook. The data collected by the patient were automatically transmitted via the telephone network every night. The study population consisted of 30 patients with type I diabetes, who were randomly allocated to the home telecare group or the control group. The control group was treated based on clinical examinations performed every three weeks. In the home telecare group, the patient-collected data were transmitted to hospital daily, enabling more frequent interventions by the doctor. The average study period was 180 days (SD 22) in the home telecare group and 176 days (SD 16) in the control group. The mean level of metabolic control and the insulin dose adjustment patterns were very similar in both groups regardless of the much higher (15 times) reporting frequency in the home telecare group. The patient-collected data were not fully utilized, mainly because of too high within-day variability in glycaemic control and the high workload connected with daily data analysis.


Subject(s)
Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1/drug therapy , Insulin/administration & dosage , Pregnancy in Diabetics , Telemedicine , Diabetes Mellitus, Type 1/blood , Female , Glycated Hemoglobin/metabolism , Humans , Pregnancy , Prospective Studies , Telemedicine/instrumentation
9.
Article in English | MEDLINE | ID: mdl-12906307

ABSTRACT

Formulation of membrane properties is important prior the successful implantation of encapsulated cells producing therapeutically relevant compounds. The purpose of our study was to specify the methods allowing preliminary evaluation of hollow fibers (HF) chosen for immunoisolation. We have selected as estimates (1) diffusive permeability for small and large solutes, and HF cut off (in vitro), (2) histological evaluation of tissue overgrowth after sc. implantation into mice. It was found that diffusive coefficients were linearly dependent on the particle diameter except that of albumin (2-3 times higher than theoretically estimated). This discrepancy imply that for certain particles the interaction with membrane material may be significant. The histological evaluation showed that siliconized HF implanted for 105 days were accepted (there was thin fibrotic layer on the external surface of the HF, no surrounding haemopoietic cells were found). It is concluded that proposed methods for preliminary evaluation of hollow fibers chosen for immunoisolation seems to be reliable and suitable for testing diffusive permeability of each relevant cell product.


Subject(s)
Capsules/chemistry , Cells, Immobilized/cytology , Polypropylenes/chemistry , Transplants , Blood Flow Velocity , Cell Survival/immunology , Cells, Immobilized/immunology , Diffusion , Fibroblasts , Models, Cardiovascular , Silicon