1.
Anal Chem ; 94(15): 5909-5917, 2022 04 19.
Article in English | MEDLINE | ID: mdl-35380435

ABSTRACT

SARS-CoV-2 cellular infection is mediated by the heavily glycosylated spike protein. Recombinant versions of the spike protein and the receptor-binding domain (RBD) are necessary for seropositivity assays and can potentially serve as vaccines against viral infection. RBD plays key roles in the spike protein's structure and function, and thus, comprehensive characterization of recombinant RBD is critically important for biopharmaceutical applications. Liquid chromatography coupled to mass spectrometry has been widely used to characterize post-translational modifications in proteins, including glycosylation. Most studies of RBDs were performed at the proteolytic peptide (bottom-up proteomics) or released glycan level because of the technical challenges in resolving highly heterogeneous glycans at the intact protein level. Herein, we evaluated several online separation techniques: (1) C2 reverse-phase liquid chromatography (RPLC), (2) capillary zone electrophoresis (CZE), and (3) acrylamide-based monolithic hydrophilic interaction chromatography (HILIC) to separate intact recombinant RBDs with varying combinations of glycosylations (glycoforms) for top-down mass spectrometry (MS). Within the conditions we explored, the HILIC method was superior to RPLC and CZE at separating RBD glycoforms, which differ significantly in neutral glycan groups. In addition, our top-down analysis readily captured unexpected modifications (e.g., cysteinylation and N-terminal sequence variation) and low abundance, heavily glycosylated proteoforms that may be missed by using glycopeptide data alone. The HILIC top-down MS platform holds great potential in resolving heterogeneous glycoproteins for facile comparison of biosimilars in quality control applications.


Subject(s)
Biosimilar Pharmaceuticals , COVID-19 , Chromatography, Liquid , Chromatography, Reverse-Phase/methods , Glycoproteins/chemistry , Humans , Hydrophobic and Hydrophilic Interactions , Mass Spectrometry , Polysaccharides/analysis , SARS-CoV-2 , Spike Glycoprotein, Coronavirus/chemistry
2.
Anal Chem ; 93(45): 14966-14975, 2021 11 16.
Article in English | MEDLINE | ID: mdl-34726890

ABSTRACT

The unanticipated discovery of recent ultra-high-resolution ion mobility spectrometry (IMS) measurements revealing that isotopomers─compounds that differ only in the isotopic substitution sites─can be separated has raised questions as to the physical basis for their separation. A study comparing IMS separations for two isotopomer sets in conjunction with theory and simulations accounting for ion rotational effects provides the first-ever prediction of rotation-mediated shifts. The simulations produce observable mobility shifts due to differences in gas-ion collision frequency and translational-to-rotational energy transfer. These differences can be attributed to distinct changes in the moment of inertia and center of mass between isotopomers. The simulations are in broad agreement with the observed experiments and consistent with relative mobility differences between isotopomers. These results provide a basis for refining IMS theory and a new foundation to obtain additional structural insights through IMS.


Subject(s)
Ion Mobility Spectrometry
3.
Anal Chem ; 93(43): 14432-14439, 2021 11 02.
Article in English | MEDLINE | ID: mdl-34669385

ABSTRACT

Accurate and comprehensive identification of residual glycerides in biodiesel is an important part of fuel characterization due to the impact of glycerides on the fuel physicochemical properties. However, analysis of bound glycerol in biodiesel samples faces challenges due to lack of readily available standards of structurally complex glyceride species in nontraditional biodiesel feedstocks and a risk of misannotation in the presence of impurities in gas chromatographic separations. Here, we evaluate methane and isobutane chemical ionization-single quadrupole mass spectrometry combined with high-temperature gas chromatography separations for mapping monoacylglycerols, diacylglycerols, and triacylglycerols in biodiesel. Unlike electron impact ionization, which produces mostly in-source fragments, isobutane chemical ionization spectra of tetramethylsilyl-derivatized monoacylglycerols and diacylglycerols are dominated by molecular ions and M-SiO(CH3)3+ ions, which provide important diagnostic information. We demonstrate the utility of isobutane chemical ionization in identifying structurally complex glycerolipid standards as well as species in biodiesel samples from different plant and animal feedstocks.


Subject(s)
Biofuels , Glycerides , Animals , Biofuels/analysis , Gas Chromatography-Mass Spectrometry , Glycerol/analysis , Temperature
4.
Anal Chem ; 91(18): 11952-11962, 2019 09 17.
Article in English | MEDLINE | ID: mdl-31450886

ABSTRACT

We report on separations of ion isotopologues and isotopomers using ultrahigh-resolution traveling wave-based Structures for Lossless Ion Manipulations with serpentine ultralong path and extended routing ion mobility spectrometry coupled to mass spectrometry (SLIM SUPER IMS-MS). Mobility separations of ions from the naturally occurring ion isotopic envelopes (e.g., [M], [M+1], [M+2], ... ions) showed the first and second isotopic peaks (i.e., [M+1] and [M+2]) for various tetraalkylammonium ions could be resolved from their respective monoisotopic ion peak ([M]) after SLIM SUPER IMS with resolving powers of ∼400-600. Similar separations were obtained for other compounds (e.g., tetrapeptide ions). Greater separation was obtained using argon versus helium drift gas, as expected from the greater reduced mass contribution to ion mobility described by the Mason-Schamp relationship. To more directly explore the role of isotopic substitutions, we studied a mixture of specific isotopically substituted (15N, 13C, and 2H) protonated arginine isotopologues. While the separations in nitrogen were primarily due to their reduced mass differences, similar to the naturally occurring isotopologues, their separations in helium, where higher resolving powers could also be achieved, revealed distinct additional relative mobility shifts. These shifts appeared correlated, after correction for the reduced mass contribution, with changes in the ion center of mass due to the different locations of heavy atom substitutions. The origin of these apparent mass distribution-induced mobility shifts was then further explored using a mixture of Iodoacetyl Tandem Mass Tag (iodoTMT) isotopomers (i.e., each having the same exact mass, but with different isotopic substitution sites). Again, the observed mobility shifts appeared correlated with changes in the ion center of mass leading to multiple monoisotopic mobilities being observed for some isotopomers (up to a ∼0.04% difference in mobility). These mobility shifts thus appear to reflect details of the ion structure, derived from the changes due to ion rotation impacting collision frequency or momentum transfer, and highlight the potential for new approaches for ion structural characterization.


Subject(s)
Deuterium/chemistry , Carbon Isotopes/chemistry , Ion Mobility Spectrometry , Ions/chemistry , Ions/isolation & purification , Mass Spectrometry , Nitrogen Isotopes/chemistry
5.
Analyst ; 144(2): 454-462, 2019 Jan 14.
Article in English | MEDLINE | ID: mdl-30444223

ABSTRACT

A separation voltage polarity switching transient capillary isotachophoresis (PS-tCITP) was developed to overcome a major sample loading volume limitation in transient capillary isotachophoresis (tCITP). The fundamental idea of PS-tCITP is to let sample ions move back and forth in a separation capillary during their initial isotachophoresis focusing stage by switching the polarity of the separation voltage, in order to both increase the sample loading volume and improve the separation efficiency as compared to the conventional tCITP method. The experimental evaluation of the novel PS-tCITP method by using two peptide standards at 2 µM concentration showed that the maximum sample loading volume could be increased from 45% of the total separation capillary volume in tCITP to 70% in PS-tCITP, which resulted in a more than 1.5 fold increase in the peptide peak intensity at a given length/volume of the separation capillary. Due to the consecutive focusing of sample volume from each polarity switching of the separation voltage, the separation time window at a given sample loading volume was also increased significantly in PS-tCITP as compared to tCITP. Experiment comparison between tCITP and PS-tCITP at 45% sample loading volume using the same setup showed that the migration time difference between the two peptide peaks increased from 0.3 min in tCITP to 0.363 min in PS-tCITP with similar peak widths and heights, resulting in roughly a 21% improvement in separation resolution. The performance advantages of PS-tCITP separation over tCITP separation were further verified by using a mixture of six peptide standards.

6.
Annu Rev Anal Chem (Palo Alto Calif) ; 10(1): 71-92, 2017 06 12.
Article in English | MEDLINE | ID: mdl-28301728

ABSTRACT

Ion mobility spectrometry (IMS) is a widely used analytical technique for rapid molecular separations in the gas phase. Though IMS alone is useful, its coupling with mass spectrometry (MS) and front-end separations is extremely beneficial for increasing measurement sensitivity, peak capacity of complex mixtures, and the scope of molecular information available from biological and environmental sample analyses. In fact, multiple disease screening and environmental evaluations have illustrated that the IMS-based multidimensional separations extract information that cannot be acquired with each technique individually. This review highlights three-dimensional separations using IMS-MS in conjunction with a range of front-end techniques, such as gas chromatography, supercritical fluid chromatography, liquid chromatography, solid-phase extractions, capillary electrophoresis, field asymmetric ion mobility spectrometry, and microfluidic devices. The origination, current state, various applications, and future capabilities of these multidimensional approaches are described in detail to provide insight into their uses and benefits.


Subject(s)
Mass Spectrometry/methods , Bacterial Toxins/analysis , Chromatography, Liquid , Chromatography, Supercritical Fluid , Environmental Monitoring , Gases/chemistry , Ions/chemistry , Mass Spectrometry/instrumentation , Microfluidics/methods , Pharmaceutical Preparations/analysis
7.
Int J Mol Sci ; 18(1)2017 Jan 18.
Article in English | MEDLINE | ID: mdl-28106768

ABSTRACT

Understanding the biological roles and mechanisms of lipids and glycolipids is challenging due to the vast number of possible isomers that may exist. Mass spectrometry (MS) measurements are currently the dominant approach for studying and providing detailed information on lipid and glycolipid presence and changes. However, difficulties in distinguishing the many structural isomers, due to the distinct lipid acyl chain positions, double bond locations or specific glycan types, inhibit the delineation and assignment of their biological roles. Here we utilized ultra-high resolution ion mobility spectrometry (IMS) separations by applying traveling waves in a serpentine multi-pass Structures for Lossless Ion Manipulations (SLIM) platform to enhance the separation of selected lipid and glycolipid isomers. The multi-pass arrangement allowed the investigation of paths ranging from ~16 m (one pass) to ~60 m (four passes) for the distinction of lipids and glycolipids with extremely small structural differences. These ultra-high resolution SLIM IMS-MS analyses provide a foundation for exploring and better understanding isomer-specific biological activities and disease processes.


Subject(s)
Glycolipids/isolation & purification , Mass Spectrometry/methods , Glycolipids/chemistry , Isomerism
8.
Anal Chem ; 88(24): 12152-12160, 2016 12 20.
Article in English | MEDLINE | ID: mdl-28193022

ABSTRACT

Complex samples benefit from multidimensional measurements where higher resolution enables more complete characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometer (IMS-Orbitrap MS) platform. To circumvent the time scale disparity between the fast IMS separation and the much slower Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequences to multiplex the injection of ions and allow operation in signal averaging (SA), single multiplexing (SM), and double multiplexing (DM) IMS modes to optimize the signal-to-noise ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data. A new algorithm was developed for the DM analyses involving a two-step process that first recovers the SM data and then decodes the SM data. The algorithm also performs multiple refining procedures to minimize demultiplexing artifacts. The new IMS-Orbitrap MS platform was demonstrated by the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulas.


Subject(s)
Ion Mobility Spectrometry/instrumentation , Mass Spectrometry/instrumentation , Algorithms , Animals , Artifacts , Cattle , Equipment Design , Ions/analysis , Petroleum/analysis , Phosphopyruvate Hydratase/chemistry , Proteomics/instrumentation , Serum Albumin, Bovine/chemistry
9.
Proteomics ; 16(2): 188-96, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26508368

ABSTRACT

Capillary zone electrophoresis (CZE) is emerging as a useful tool in proteomic analysis. Interest arises from dramatic improvements in performance that result from improvements in the background electrolyte used for the separation, the incorporation of advanced sample injection methods, the development of robust and sensitive electrospray interfaces, and the coupling with Orbitrap mass spectrometers with high resolution and sensitivity. The combination of these technologies produces performance that is rapidly approaching the performance of UPLC-based methods for microgram samples and exceeds the performance of UPLC-based methods for mid- to low nanogram samples. These systems now produce over 10 000 peptide IDs in a single 100-min analysis of the HeLa proteome.


Subject(s)
Proteome/isolation & purification , Electrophoresis, Capillary/standards , Humans , Proteomics/methods , Quality Improvement , Spectrometry, Mass, Electrospray Ionization
11.
Article in English | MEDLINE | ID: mdl-25913424

ABSTRACT

While capillary zone electrophoresis (CZE) has been used to produce very rapid and efficient separations, coupling these high-speed separations with mass spectrometry (MS) has been challenging. Now, with much faster and sensitive mass spectrometers, it is possible to take full advantage of the CZE speed and reconstruct the fast migrating peaks. Here are three high-speed CZE-MS analyses via an electrokinetically pumped sheath-flow interface. The first separation demonstrates CZE-ESI-MS of an amino acid mixture with a 2-min separation, >50,000 theoretical plates, low micromolar concentration detection limits, and subfemtomole mass detection limits (LTQ XL mass spectrometer). The second separation with our recently improved third-generation CE-MS interface illustrates a 20 amino acid separation in ∼7min with an average over 200,000 plate counts, and results in almost-baseline resolution of structural isomers, leucine and isoleucine. The third separation is of a BSA digest with a reproducible CZE separation and mass spectrometry detection in 2min. CZE-MS/MS analysis of the BSA digest identified 31 peptides, produced 52% sequence coverage, and generated a peak capacity of ∼40 across the 1-min separation window (Q-Exactive mass spectrometer).


Subject(s)
Amino Acids/analysis , Electrophoresis, Capillary/methods , Serum Albumin, Bovine/chemistry , Tandem Mass Spectrometry/methods , Amino Acids/isolation & purification , Animals , Cattle , Electrophoresis, Capillary/economics , Spectrometry, Mass, Electrospray Ionization/economics , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/economics , Time Factors
12.
Talanta ; 116: 985-90, 2013 Nov 15.
Article in English | MEDLINE | ID: mdl-24148505

ABSTRACT

Automated diagonal capillary electrophoresis is a two-dimensional separation method that incorporates an immobilized enzyme reactor at the distal end of the first capillary and employs identical electrophoretic separation modes in both dimensions. Components undergo a preliminary separation in the first capillary. Fractions are parked in the reactor where some components undergo transformation. The fractions are then periodically transferred to the second capillary and replaced by the next components in the sample. Components that are not modified by the reactor will have identical mobility in both dimensions and fall on the diagonal of a reconstructed two-dimensional electropherogram, while analyte that undergoes modification will fall off the diagonal. In this study, alkaline phosphatase was immobilized in a monolithic reactor. An LTQ-Orbitrap Velos mass spectrometer was used to monitor analytes as they migrated from the second capillary. The system was used to characterize the phosphorylation status of a tryptic digest of α-casein in a background prepared from a 22-fold excess of the tryptic digest of bovine serum albumin. 120 fractions underwent automated treatment in the alkaline phosphatase reactor and separation in the second dimension capillary for over 40 min; nine phosphorylated α-casein peptides that produced 20 different phosphorylation states were detected with high confidence.


Subject(s)
Alkaline Phosphatase/chemistry , Caseins/chemistry , Electrophoresis, Capillary/methods , Enzymes, Immobilized/chemistry , Peptide Fragments/analysis , Phosphoproteins/analysis , Amino Acid Sequence , Animals , Cattle , Electrophoresis, Capillary/instrumentation , Molecular Sequence Data , Phosphoproteins/chemistry , Phosphorylation , Proteolysis , Serum Albumin, Bovine/chemistry , Tandem Mass Spectrometry , Trypsin/chemistry
13.
Analyst ; 138(11): 3181-8, 2013 Jun 07.
Article in English | MEDLINE | ID: mdl-23591184

ABSTRACT

Capillary zone electrophoresis-multiple/single reaction monitoring (CZE-MRM/SRM), which employed an electrokinetically driven sheath-flow electrospray interface, was used for the rapid and highly sensitive detection of protein analytes in complex tryptic digests. MRM channels were developed against a commercial exponential mixture of bovine proteins. Five proteins spanning four orders of magnitude concentration range were confidently detected from only 2.5 ng of the digest mixture; the mass detection limits (S/N = 3) of two detected proteins, alpha-casein and glutamate dehydrogenase were about 600 zmol and 30 amol, respectively. This technique was then applied to a RAW 264.7 cell lysate digest. Three proteins were confidently and reproducibly detected from 100 pg of this digest. The sample amount corresponds to the approximate protein content from a single cell, which suggests that CZE-MRM may be a useful analytical tool in chemical cytometry. In addition to providing highly sensitive detection of proteins in complex mixtures, this system is highly rapid; migration time of the protein digests was less than 10 min.


Subject(s)
Electrophoresis, Capillary/methods , Proteolysis , Trypsin/metabolism , Animals , Cattle , Cell Death , Cell Line , Mice , Proteins/analysis , Proteins/isolation & purification , Proteins/metabolism , Reproducibility of Results , Time Factors
14.
Talanta ; 98: 253-6, 2012 Aug 30.
Article in English | MEDLINE | ID: mdl-22939156

ABSTRACT

A rapid and reproducible system that couples capillary isoelectric focusing to a high-resolution mass spectrometer was developed for on-line analysis and identification of protein digests. Magnetic microsphere-based immobilized trypsin was used for protein digestion to reduce the digestion time to 10 min, with a total analysis time of 4h. A three-protein-mixture (myoglobin, BSA, cytochrome c) with a molarity ratio of 1:10:50 was successfully digested and identified. This system was also used to analyze host cell protein impurities in a recombinant humanized monoclonal antibody product in which the sample was product-depleted using affinity capture on protein A/protein L columns prior to analysis. A database search identified 37 host cell proteins with peptide and protein identity probability greater than 0.9.


Subject(s)
Antibodies, Monoclonal/analysis , Peptide Fragments/analysis , Recombinant Proteins/analysis , Trypsin/chemistry , Amino Acid Sequence , Animals , Antibodies, Monoclonal/chemistry , Cattle , Chromatography, Affinity , Cytochromes c/analysis , Databases, Protein , Enzymes, Immobilized/chemistry , Humans , Isoelectric Focusing , Magnetics , Microspheres , Molecular Sequence Data , Myoglobin/analysis , Recombinant Proteins/chemistry , Serum Albumin, Bovine/analysis , Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry , Time Factors
15.
Proteomics ; 12(19-20): 3013-9, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22888077

ABSTRACT

We report the performance of capillary zone electrophoresis coupled with an electrokinetically pumped electrospray interface and an Orbitrap-Velos mass spectrometer for high sensitivity protein analysis. We first investigated the system for quantitation of the tryptic digest of BSA. The system produced outstanding linearity with respect to peak height, number of peptide IDs, and spectral counts across the range of 12 nM to 750 nM (60 amol to 3.5 fmol) of BSA injected. One peptide produced a detection limit of 0.3 nM (1.5 amol) injected. We also analyzed 700 pg of a tryptic digest prepared from a RAW264.7 cell lysate; ten proteins were identified in triplicate analyses after filtering the data with peptide confidence value as high. This sample size corresponds to the protein content of approximately ten eukaryotic cells.


Subject(s)
Cell Extracts/chemistry , Electrophoresis, Capillary/methods , Peptide Fragments/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Trypsin/chemistry , Animals , Cattle , Cell Line , Databases, Protein , Limit of Detection , Linear Models , Mice , Peptide Fragments/chemistry , Peptide Fragments/metabolism , Peptide Mapping , Reproducibility of Results , Serum Albumin, Bovine/chemistry , Serum Albumin, Bovine/metabolism , Trypsin/metabolism
16.
Anal Chem ; 84(14): 6116-21, 2012 Jul 17.
Article in English | MEDLINE | ID: mdl-22690842

ABSTRACT

We demonstrate the use of capillary zone electrophoresis with an electrokinetic sheath-flow electrospray interface coupled to a triple-quadrupole mass spectrometer for the accurate and precise quantification of Leu-enkephalin in a complex mixture using multiple-reaction monitoring (MRM). Assay time is <6 min, with no re-equilibration required between runs. A standard curve of Leu-enkephalin was performed in the presence of a background tryptic digest of bovine albumin. We demonstrate reasonably reproducible peak heights (21% relative standard deviation), retention times (better than 1% relative standard deviation), and robust electrospray quality. Our limit of detection (3σ) was 60 pM, which corresponds to the injection of 335 zmol of peptide. This is a 10-20-fold improvement in mass sensitivity than we have obtained by nano HPLC/MRM and substantially better than reported for LC/MS/MS. Further quantification was performed in the presence of stable-isotope-labeled versions of the peptides; under these conditions, linearity was observed across nearly 4 orders of magnitude. The concentration detection limit was 240 pM for the stable-isotope-labeled quantification.


Subject(s)
Electrophoresis, Capillary/methods , Enkephalin, Leucine/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Animals , Cattle , Enkephalin, Leucine/chemistry , Limit of Detection , Time Factors
17.
Talanta ; 88: 324-9, 2012 Jan 15.
Article in English | MEDLINE | ID: mdl-22265506

ABSTRACT

Capillary electrophoresis can provide fast and efficient separations of peptides. However, the high speed separation and limited loading capacity of capillary electrophoresis requires the use of a fast and sensitive detector. While laser-induced fluorescence provides exquisite sensitivity and millisecond response time, it inherently generates a low information content signal. In contrast, mass spectrometry provides an information rich signal that is attractive for peptide analysis. The recently introduced Velos-Orbitrap mass spectrometer is capable of fast and sensitive tandem MS acquisition and simultaneous high accuracy MS acquisition, which is well suited for coupling with fast and efficient separation methods for peptide analysis. We evaluated this instrument as a detector for peptide separation by capillary electrophoresis. In MS mode, we observed low attomole detection limits for a number of peptides in a tryptic digest of standard proteins with high mass resolution (30,000 at m/z 400). The response time of the Orbitrap at this resolution was ∼0.70s, which was adequate to reconstruct the peak shape and area of our electrophoretic peaks. The linear ion-trap successfully recorded tandem MS spectra of tryptic peptides at 20 nM concentration.


Subject(s)
Electrophoresis, Capillary/methods , Peptides/analysis , Saccharomyces cerevisiae Proteins/analysis , Tandem Mass Spectrometry/methods , Molecular Weight , Saccharomyces cerevisiae/chemistry , Sensitivity and Specificity , Time Factors
18.
Anal Chem ; 84(3): 1617-22, 2012 Feb 07.
Article in English | MEDLINE | ID: mdl-22182061

ABSTRACT

We demonstrate the use of capillary zone electrophoresis with an electrokinetically pumped sheath-flow electrospray interface for the analysis of a tryptic digest of a sample of intermediate protein complexity, the secreted protein fraction of Mycobacterium marinum. For electrophoretic analysis, 11 fractions were generated from the sample using reverse-phase liquid chromatography; each fraction was analyzed by CZE-ESI-MS/MS, and 334 peptides corresponding to 140 proteins were identified in 165 min of mass spectrometer time at 95% confidence (FDR < 0.15%). In comparison, 388 peptides corresponding to 134 proteins were identified in 180 min of mass spectrometer time by triplicate UPLC-ESI-MS/MS analyses, each using 250 ng of the unfractionated peptide mixture, at 95% confidence (FDR < 0.15%). Overall, 62% of peptides identified in CZE-ESI-MS/MS and 67% in UPLC-ESI-MS/MS were unique. CZE-ESI-MS/MS favored basic and hydrophilic peptides with low molecular masses. Combining the two data sets increased the number of unique peptides by 53%. Our approach identified more than twice as many proteins as the previous record for capillary electrophoresis proteome analysis. CE-ESI-MS/MS is a useful tool for the analysis of proteome samples of intermediate complexity.


Subject(s)
Chromatography, High Pressure Liquid , Electrophoresis, Capillary , Proteomics , Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry , Chromatography, Reverse-Phase , Mycobacterium marinum/metabolism , Peptides/analysis , Proteins/analysis
19.
J Chromatogr A ; 1218(15): 2007-11, 2011 Apr 15.
Article in English | MEDLINE | ID: mdl-21030030

ABSTRACT

We describe a two-dimensional capillary electrophoresis system that incorporates a replaceable enzymatic microreactor for on-line protein digestion. In this system, trypsin is immobilized on magnetic beads. At the start of each experiment, old beads are flushed to waste and replaced with a fresh plug of beads, which is captured by a pair of magnets at the distal tip of the first capillary. For analysis, proteins are separated in the first capillary. A fraction is then parked in the reactor to create peptides. Digested peptides are periodically transferred to the second capillary for separation; a fresh protein fraction is simultaneously moved to the reactor for digestion. An electrospray interface is used to introduce peptides into a mass spectrometer for analysis. This procedure is repeated for several dozen fractions under computer control. The system was demonstrated by the separation and digestion of insulin chain b oxidized and ß-casein as model proteins.


Subject(s)
Electrophoresis, Capillary/methods , Electrophoresis, Gel, Two-Dimensional/methods , Enzymes, Immobilized/metabolism , Magnetics , Peptide Fragments/analysis , Tandem Mass Spectrometry/methods , Animals , Caseins/analysis , Caseins/isolation & purification , Caseins/metabolism , Cattle , Insulin/analysis , Insulin/isolation & purification , Insulin/metabolism , Models, Chemical , Peptide Fragments/isolation & purification , Peptide Fragments/metabolism , Trypsin/metabolism
20.
Rapid Commun Mass Spectrom ; 24(17): 2554-60, 2010 Sep 15.
Article in English | MEDLINE | ID: mdl-20740530

ABSTRACT

We report a simple nanospray sheath-flow interface for capillary electrophoresis. This interface relies on electrokinetic flow to drive both the separation and the electrospray; no mechanical pump is used for the sheath flow. This system was interfaced with an LCQ mass spectrometer. The best results were observed with a 2-microm diameter emitter tip and a 1-mm spacing between the separation capillary tip and the emitter tip. Under these conditions, mass detection limits (3sigma) of 100 amol were obtained for insulin receptor fragment 1142-1153. The separation efficiency exceeded 200,000 plates for this compound. The relative standard deviation generated during continual infusion of a 50 microM solution of angiotensin II was 2% for the total ion count and 3% for the extracted ion count over a 40-min period. Finally, the interface was also demonstrated for negative ion mode.


Subject(s)
Electrophoresis, Capillary/instrumentation , Peptides/chemistry , Spectrometry, Mass, Electrospray Ionization , Angiotensin II/chemistry , Equipment Design , Humans , Least-Squares Analysis , Models, Chemical , Peptides/isolation & purification , Receptor, Insulin/chemistry , Spectrometry, Mass, Electrospray Ionization/instrumentation , Spectrometry, Mass, Electrospray Ionization/methods