Knee Surg Sports Traumatol Arthrosc ; 27(4): 1251-1258, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30361757

ABSTRACT

PURPOSE: To study the pattern of migration and clinical results up to 10 years of uncemented versus cemented fixation of the femoral component in total knee arthroplasty. METHODS: Randomized controlled trial was conducted of 41 patients (23 women, 18 men) under the age of 60 years using radiostereometric analysis. RESULTS: About two-thirds of the cemented implants and half of the uncemented implants stabilized between 2 and 10 years, while the remainder displayed a small annual increase of maximum total point motion of 0.09-0.10 mm/year. At 10 years there were no statistically significant differences in migration or clinical results between the groups. CONCLUSION: Uncemented fixation with titanium fiber mesh coating of the femoral component in total knee arthroplasty works equally as well as cemented fixation up to 10 years. An annual migration of 0.1 mm seems compatible with excellent long-term performance. LEVEL OF EVIDENCE: I.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Bone Cements , Femur/surgery , Knee Joint/surgery , Knee Prosthesis , Range of Motion, Articular/physiology , Aged , Female , Femur/diagnostic imaging , Follow-Up Studies , Humans , Knee Joint/diagnostic imaging , Knee Joint/physiopathology , Male , Middle Aged , Radiostereometric Analysis , Retrospective Studies , Treatment Outcome