Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
J Surg Res ; 232: 1-6, 2018 12.
Article in English | MEDLINE | ID: mdl-30463704

ABSTRACT

BACKGROUND: The purpose of this study is to compare the ablation performance between a synchronous microwave ablation (MWA) system and a commercially available asynchronous system in ex vivo bovine liver and evaluate the efficacy of ablation at varying entrance angles. MATERIALS AND METHODS: Two 915-MHz MWA systems were used in bench top ex vivo bovine livers with various conditions (synchronous versus asynchronous). Using synchronous technology ablations to liver, kidney, or lung at angles of 0, 15, 30, and 90° were evaluated. RESULTS: Synchronous and asynchronous MWA systems created mean ablation zone volumes of 26.4 and 15.8 cm3, 62.9 and 45.4 cm3, 90.8 and 56.4, and 75.7 and 54.8 cm3 with single, double (2 microwave probes in use simultaneous) (2 cm spacing), and triple (three probes in use simultaneously) (2 cm and 3 cm spacing) antennae configurations, respectively; adjusted P-values ≤ 0.006. Ablation defects were similar across all groups when evaluated for entrance angle. Specifically, when comparing 0-degree angle to all other angles, achieved zones of ablation (ZA) were similar (mean ± standard deviation for 0-degree versus all other angles: 8.72 ± 4.84 versus 9.38 ± 4.11 cm2, P = 0.75). The use of the long-tip probe resulted in a statistically significant increase in the achieved ZA when compared to the short tip probe (10.9 ± 4.3 versus 6.5 ± 2.4, respectively; P = 0.01). CONCLUSIONS: Newly developed synchronous microwave technology creates significantly larger ablation zones when compared to an existing asynchronous commercially available system. The angle of approach does not affect the resulting ZA. This is clinically relevant as true 0-degree angle is often difficult to obtain.


Subject(s)
Catheter Ablation/methods , Microwaves/therapeutic use , Animals , Swine
2.
Eur J Radiol ; 89: 136-139, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28267529

ABSTRACT

PURPOSE: CT-beam hardening artifact can make tumor margin visualization and its relationship to the ablation applicator tip challenging. To determine optimal scanning parameters for commonly-used applicators. MATERIALS AND METHODS: Applicators were placed in ex-vivo cow livers with implanted mock tumors, surrounded by bolus gel. Various CT scans were performed at 440mA with 5mm thickness changing kVp, scan time, ASiR, scan type, pitch, and reconstruction algorithm. Four radiologists blindly scored the images for image quality and artifact quantitatively. RESULTS: A significant relationship between probe, kVp level, ASiR level, and reconstruction algorithm was observed concerning both image artifact and image quality (both p=<0.0001). Specifically, there are certain combinations of kVp, ASiR, and reconstruction algorithm that yield better images than other combinations. In particular, one probe performed equivalently or better than any competing probe considered here, regardless of kVp, ASiR, and reconstruction algorithm combination. CONCLUSION: The findings illustrate the overall interaction of the effects of kVp, ASiR, and reconstruction algorithm within and between probes, so that radiologists may easily reference optimal imaging performance for a certain combinations of kVp, ASiR, reconstruction algorithm and probes at their disposal. Optimum combinations for each probe are provided.


Subject(s)
Ablation Techniques/instrumentation , Liver/diagnostic imaging , Neoplasms/diagnostic imaging , Ablation Techniques/methods , Algorithms , Animals , Artifacts , Cattle , Female , Humans , Neoplasms/surgery , Phantoms, Imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Interventional/methods , Tomography, X-Ray Computed/methods
3.
Eur J Radiol ; 84(6): 1083-90, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25818732

ABSTRACT

PURPOSE: To retrospectively evaluate the safety and efficacy of microwave ablation (MWA) as treatment for single, focal hepatic malignancies. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant study. From December 2003 to May 2012, 64 patients were treated with MWA for a single hepatic lesion, in 64 sessions. Hepatocellular carcinoma (HCC) was treated in 25 patients (geometric mean tumor size, 3.33-cm; 95% CI, 2.65-4.18-cm; range, 1.0-12.0-cm), metastatic colorectal cancer (CRC) was treated in 27 patients (geometric mean tumor size, 2.7-cm; 95% CI, 2.20-3.40-cm; range, 0.8-6.0-cm), and other histological-types were treated in 12 patients (geometric mean tumor size, 3.79-cm; 95% CI, 2.72-5.26-cm; range, 1.7-8.0-cm). Kaplan-Meier (K-M) method was used to analyze time event data. Chi-square and correlation evaluated the relationship between tumor size and treatment parameters. RESULTS: Technical success rate was 95.3% (61/64). Treatment parameters were tailored to tumor size; as size increased more antennae were used (p<0.001), treatment with multiple activations increased (p<0.028), and treatment time increased (p<0.001). There was no statistically significant relationship between time to recurrence and tumor size, number of activations, number of antennae, and treatment time. At one-year, K-M analysis predicted a likelihood of local recurrence of 39.8% in HCC patients, 45.7% in CRC metastases patients, and 70.8% in patients with other metastases. Median cancer specific survivals for patients were 38.3 months for HCC patients, 36.3 months for CRC metastases, and 13.9 months for other histological-types. Complications occurred in 23.4% (15/64) of sessions. CONCLUSION: In our sample, tumor size did not appear to impact complete ablation rates or local recurrence rates for focal hepatic malignancies treated with MWA.


Subject(s)
Ablation Techniques/methods , Carcinoma, Hepatocellular/surgery , Liver Neoplasms/surgery , Adult , Aged , Female , Humans , Male , Microwaves , Middle Aged , Retrospective Studies , Treatment Outcome
4.
Radiology ; 262(1): 353-60, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22106348

ABSTRACT

PURPOSE: To determine histologic changes induced by microwave ablation (MWA) in patients with pulmonary malignancy by using an ablation system with tumor permittivity feedback control, enabling real-time modulation of energy power and frequency. MATERIALS AND METHODS: Institutional review board approval and patient informed consent were obtained for this prospective HIPAA-complaint ablation and resection study. Between March 2009 and January 2010, 10 patients (four women, six men; mean age, 71 years; age range, 52-82 years) underwent intraoperative MWA of pulmonary malignancies. Power (10-32 W) and frequency (908-928 MHz) were continuously adjusted by the generator to maintain a temperature of 110°-120°C at the 14-gauge antenna tip for one 10-minute application. After testing for an air leak, tumors were resected surgically. Gross inspection, slicing, and hematoxylin-eosin (10 specimens) and nicotinamide adenine dinucleotide (six specimens) staining were performed. RESULTS: Tumors included adenocarcinomas (n = 5), squamous cell carcinomas (n = 3), and metastases from endometrial (n = 1) and colorectal (n = 1) primary carcinomas. Mean maximum tumor diameter was 2.4 cm (range, 0.9-5.0 cm), and mean maximum volume was 8.6 cm(3) (range, 0.5-52.7 cm(3)). One air leak was detected. Five of 10 specimens were grossly measurable, revealing a mean maximum ablation zone diameter of 4.8 cm (range, 3.0-6.5 cm) and a mean maximum ablation zone volume of 15.1 cm(3) (range, 7.3-25.1 cm(3)). At hematoxylin-eosin staining, coagulation necrosis was observed in all ablation zones, extended into the normal lung in nine of 10 specimens, and up to blood vessel walls without evidence of vessel (>4 mm) thrombosis. Nicotinamide adenine dinucleotide staining enabled confirmation of no viability within ablation zones extending into normal lung in five of six specimens. CONCLUSION: MWA with tumor permittivity feedback control results in cytotoxic intratumoral temperatures and extension of ablation zones into aerated peritumoral pulmonary parenchyma, possibly forming the equivalent of an oncologic resection margin.


Subject(s)
Catheter Ablation/methods , Lung Neoplasms/surgery , Microwaves/therapeutic use , Aged , Aged, 80 and over , Biopsy , Feedback , Female , Humans , Lung Neoplasms/pathology , Male , Middle Aged , Neoplasm Staging , Positron-Emission Tomography , Prospective Studies , Tomography, X-Ray Computed , Treatment Outcome
5.
Eur J Radiol ; 81(8): 1717-23, 2012 Aug.
Article in English | MEDLINE | ID: mdl-21636231

ABSTRACT

PURPOSE: To retrospectively evaluate the effectiveness and safety of image-guided ablation of adrenal tumors. MATERIALS AND METHODS: : This HIPAA-compliant study was IRB approved and informed consent was waived. From 5/1999-6/2008, 20 consecutive adrenal metastases (mean diameter 4.2cm; range, 2-8) and 3 hormonally active primary adrenal tumors (mean diameter 2.3cm; range, 1-4), including an aldosteronoma and 2 pheochromocytomas in 22 patients (14 men, 8 women; mean age 61 years; range 40-84) were ablated in 23 sessions. Bilateral metastases were treated in a single patient. Radiofrequency ablation was used to treat 16 adrenal metastases and the 3 hyperfunctioning tumors. Microwave ablation was used to treat 4 metastases. Successful treatment was defined as a lack of both enhancement on follow-up contrast enhanced CT and/or up-take on FDG PET-CT and for functioning tumors, resolution of biochemical abnormalities. RESULTS: Technical success was achieved in all sessions. Mean follow-up was 45.1 months (range, 1-91) Local tumor progression (focal enhancement at ablation site ≥1cm in short axis) was detected in 4 of 23 tumors, two of which were identified bilaterally in a single patient prompting re-treatment. Of 19 patients with metastatic disease, 16 had fatal extra-adrenal disease progression, and 3 remain alive. Two of the 3 patients who underwent ablation of hyperfunctioning tumors remain alive, including the patient with an aldosteronoma who had recurrent symptoms 91 months post ablation. Intra-ablative hypertension occurred in 9% (2/23) of sessions and was successfully treated pharmacologically. CONCLUSION: Ablation of metastatic and hyperfunctioning adrenal tumors is safe and may provide local control and treatment of pathologic biochemical activity.


Subject(s)
Adrenal Gland Neoplasms/diagnostic imaging , Adrenal Gland Neoplasms/surgery , Adrenalectomy/methods , Catheter Ablation/methods , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adrenalectomy/adverse effects , Adult , Aged , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
6.
AJR Am J Roentgenol ; 197(3): 671-5, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21862810

ABSTRACT

OBJECTIVE: The objective of our study was to report the incidence of multiple sporadic primary renal cell carcinomas (RCCs) in patients referred for radiofrequency ablation (RFA). MATERIALS AND METHODS: A retrospective search identified 162 patients (104 men and 58 women; mean age, 74 years) without a history of von Hippel-Lindau disease with a total of 175 tumors treated with RFA for biopsy-proven primary renal malignancies at our institution from 1998 to 2009. Three groups of patients with multiple RCCs were identified: patients with a history of nephrectomy for RCC who had been referred for RFA of a new renal tumor, patients who presented with multiple renal tumors at the time of referral for RFA, and patients who were shown to have developed a new renal tumor on follow-up imaging after RFA. RESULTS: Twenty-eight patients (17%) had multiple biopsy-proven RCCs. Eighteen patients (11%) had undergone prior nephrectomy for surgically proven RCC. The mean interval between prior nephrectomy and RFA referral was 122 months (range, 12-456 months). Seven patients (4%) without a history of nephrectomy presented with two biopsy-proven RCCs at RFA referral. Three patients (2%) who had not undergone nephrectomy and had a solitary RCC at the time of RFA had developed a new biopsy-proven RCC separate from the original treatment site on follow-up imaging after RFA. The mean time to diagnosis from the initial RFA treatment was 52 months (range, 25-89 months). CONCLUSION: Imaging surveillance of patients referred for renal RFA may be important not only to assess treatment success but also to detect new RCCs.


Subject(s)
Carcinoma, Renal Cell/surgery , Catheter Ablation/methods , Kidney Neoplasms/surgery , Adult , Aged , Aged, 80 and over , Biopsy , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/epidemiology , Contrast Media , Female , Humans , Incidence , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/epidemiology , Male , Middle Aged , Nephrectomy , Reoperation , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
7.
HPB (Oxford) ; 13(3): 168-73, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21309933

ABSTRACT

BACKGROUND: Irreversible electroporation (IRE) is a novel, non-thermal form of ablation. We studied the safety and efficacy of IRE for the ablation of liver tissue around the liver hilum. We also studied the ability of triphenyltetrazolium chloride staining (TTC) to predict the zone of ablation after IRE. METHODS: Eight swine underwent 20 ablations of the liver and liver hilum. Two monopolar probes were positioned 2 cm apart. IRE was performed using 90 pulses of 2500-3000 V/cm. IRE treatments were performed from 15 min to 14 days (n= 4) before sacrifice. RESULTS: All animals survived. No major complications were encountered. Ablation width ranged from 2.27 to 4.45 cm and ablation height ranged from 1.5 to 1.8 cm. TTC staining demonstrated the zone of ablation in all animals. Hepatocyte necrosis occurs immediately adjacent to large central veins without evidence of heat sink. Bile ducts, portal veins and hepatic arteries appear to be more resistant to the effects of IRE. CONCLUSIONS: IRE appears to be safe and effective for liver tissue ablation in the liver hilum. The portal structures appear more resistant to the effects of IRE. TTC staining can predict the zone of IRE ablation as early as 15 min after treatment.


Subject(s)
Catheter Ablation/methods , Electroporation/methods , Liver/surgery , Animals , Catheter Ablation/adverse effects , Coloring Agents , Female , Laparotomy , Models, Animal , Predictive Value of Tests , Sus scrofa , Tetrazolium Salts
8.
HPB (Oxford) ; 12(5): 348-51, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20590911

ABSTRACT

BACKGROUND: Irreversible electroporation (IRE) is a novel, non-thermal method of tissue ablation using short pulses of high-voltage DC current to ablate tissue. METHODS: Irreversible electroporation of the pancreas was performed in four domestic female swine using two monopolar probes spaced 9-15 mm apart. Ninety pulses of 1500 V/cm were delivered for each ablation. RESULTS: All animals survived for their designated times of 2 h (n = 1), 2 days (n = 1) and 14 days (n = 2), respectively. No procedure-related complications occurred. Three animals in which probes had been spaced at intervals of 10 ± 1 mm showed evidence of irreversible ablation, with ablation height ranging from < 10 mm to 21 mm and ablation width ranging from < 10 mm to 16 mm by gross appearance and triphenyltetrazolium chloride (TTC) staining. The only animal in which probes had been spaced at intervals of 15 mm did not show evidence of irreversible ablation at 2 weeks. This may be secondary to the wider probe spacing and relatively low voltage, which results in a mostly reversible form of electroporation without cell death. CONCLUSIONS: Irreversible electroporation appears to be a safe method for pancreas tissue ablation. Staining with TTC can predict the zone of IRE ablation within 2 h of treatment.


Subject(s)
Ablation Techniques , Electroporation , Pancreas/surgery , Ablation Techniques/adverse effects , Amylases/blood , Animals , Biomarkers/blood , Feasibility Studies , Female , Lipase/blood , Necrosis , Pancreas/enzymology , Pancreas/pathology , Pilot Projects , Sus scrofa , Time Factors
10.
Radiology ; 247(3): 871-9, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18372457

ABSTRACT

PURPOSE: To retrospectively evaluate effectiveness, follow-up imaging features, and safety of microwave ablation in 50 patients with intraparenchymal pulmonary malignancies. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board; informed consent was waived. From November 10, 2003, to August 28, 2006, 82 masses (mean, 1.42 per patient) in 50 patients (28 men, 22 women; mean age, 70 years) were percutaneously treated in 66 microwave ablation sessions. Each tumor was ablated with computed tomographic (CT) guidance. Follow-up contrast material-enhanced CT and positron emission tomographic (PET) scans were reviewed. Mixed linear modeling and logistic regression were performed. Time-event data were analyzed (Kaplan-Meier survival estimates and log-rank statistic). All event times were the time to a patient's first event (alpha level = .05, all analyses). RESULTS: At follow-up (mean, 10 months), 26% (13 of 50) of patients had residual disease at the ablation site, predicted by using index size of larger than 3 cm (P = .01). Another 22% (11 of 50) of patients had recurrent disease resulting in a 1-year local control rate of 67%, with mean time to first recurrence of 16.2 months. Kaplan-Meier analysis yielded an actuarial survival of 65% at 1 year, 55% at 2 years, and 45% at 3 years from ablation. Cancer-specific mortality yielded a 1-year survival of 83%, a 2-year survival of 73%, and a 3-year survival of 61%; these values were not significantly affected by index size of larger than 3 cm or 3 cm or smaller or presence of residual disease. Cavitation (43% [35 of 82] of treated tumors) was associated with reduced cancer-specific mortality (P = .02). Immediate complications included pneumothorax (Common Terminology Criteria for Adverse Events [CTCAE] grades 1 [18 of 66 patients] and 2 [eight of 66 patients]), hemoptysis (four of 66 patients), and skin burns (CTCAE grades 2 [one of 66 patients] and 3 [one of 66 patients]). CONCLUSION: Microwave ablation is effective and may be safely applied to lung tumors. (c) RSNA, 2008.


Subject(s)
Catheter Ablation/instrumentation , Lung Neoplasms/surgery , Microwaves/therapeutic use , Tomography, X-Ray Computed , Aged , Contrast Media , Female , Humans , Linear Models , Logistic Models , Lung Neoplasms/diagnostic imaging , Male , Retrospective Studies , Survival Rate , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...