Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Appl Clin Med Phys ; 21(12): 188-196, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33184966

ABSTRACT

PURPOSE: To evaluate two three-dimensional (3D)/3D registration platforms, one two-dimensional (2D)/3D registration method, and one 3D surface registration method (3DS). These three technologies are available to perform six-dimensional (6D) registrations for image-guided radiotherapy treatment. METHODS: Fiducial markers were asymmetrically placed on the surfaces of an anthropomorphic head phantom (n = 13) and a body phantom (n = 8), respectively. The point match (PM) solution to the six-dimensional (6D) transformation between the two image sets [planning computed tomography (CT) and cone beam CT (CBCT)] was determined through least-square fitting of the fiducial positions using singular value decomposition (SVD). The transformation result from SVD was verified and was used as the gold standard to evaluate the 6D accuracy of 3D/3D registration in Varian's platform (3D3DV), 3D/3D and 2D/3D registration in the BrainLab ExacTrac system (3D3DE and 2D3D), as well as 3DS in the AlignRT system. Image registration accuracy from each method was quantitatively evaluated by root mean square of target registration error (rmsTRE) on fiducial markers and by isocenter registration error (IRE). The Wilcoxon signed-rank test was utilized to compare the difference of each registration method with PM. A P < 0.05 was considered significant. RESULTS: rmsTRE was in the range of 0.4 mm/0.7 mm (cranial/body), 0.5 mm/1 mm, 1.0 mm/1.5 mm, and 1.0 mm/1.2 mm for PM, 3D3D, 2D3D, and 3DS, respectively. Comparing to PM, the mean errors of IRE were 0.3 mm/1 mm for 3D3D, 0.5 mm/1.4 mm for 2D3D, and 1.6 mm/1.35 mm for 3DS for the cranial and body phantoms respectively. Both of 3D3D and 2D3D methods differed significantly in the roll direction as compared to the PM method for the cranial phantom. The 3DS method was significantly different from the PM method in all three translation dimensions for both the cranial (P = 0.003-P = 0.03) and body (P < 0.001-P = 0.008) phantoms. CONCLUSION: 3D3D using CBCT had the best image registration accuracy among all the tested methods. 2D3D method was slightly inferior to the 3D3D method but was still acceptable as a treatment position verification device. 3DS is comparable to 2D3D technique and could be a substitute for X-ray or CBCT for pretreatment verification for treatment of anatomical sites that are rigid.


Subject(s)
Radiotherapy, Image-Guided , Cone-Beam Computed Tomography , Head , Humans , Imaging, Three-Dimensional , Phantoms, Imaging
2.
Radiat Oncol ; 13(1): 192, 2018 Oct 01.
Article in English | MEDLINE | ID: mdl-30285812

ABSTRACT

BACKGROUND: The SpaceOAR hydrogel is employed to limit rectal radiation dose during prostate radiotherapy. We identified a novel parameter - the product of angle θ and hydrogel volume - to quantify hydrogel placement. This parameter predicted rectum dosimetry and acute rectal toxicity in prostate cancer patients treated with stereotactic body radiotherapy to 36.25 Gy in 5 fractions. METHODS: Twenty men with low- and intermediate-risk prostate cancer underwent hydrogel placement from 2015 to 2017. Hydrogel symmetry was assessed on the CT simulation scan in 3 axial slices (midgland, 1 cm above midgland, 1 cm below midgland). Two novel parameters quantifying hydrogel placement - hydrogel volume and angle θ formed by the prostate, hydrogel, and rectum - were measured, and the normalized product of θ and hydrogel volume calculated. These were then correlated with perirectal distance, rectum maximum 1-3 cc point doses (rDmax 1-3 cc), and rectum volumes receiving 80-95% of the prescription dose (rV80-95%). Acute rectal toxicity was recorded per RTOG criteria. RESULTS: In 50% of patients, hydrogel placement was symmetric bilaterally to within 1 cm of midline in all three CT simulation scan axial slices. Lateral hydrogel asymmetry < 2 cm in any one axial slice did not affect rectum dosimetry, but absence of hydrogel in the inferior axial slice resulted in a mean increase of 171 cGy in the rDmax 1 cc (p < 0.005). The perirectal distance measured at prostate midgland, midline (mean 9.1 ± 4.3 mm) correlated strongly with rV95 (R2 0.6, p < 0.001). The mean hydrogel volume and θ were 10.3 ± 4.5 cc and 70 ± 49°, respectively. Perirectal distance, rV95 and rDmax 1 cc correlated with hydrogel angle θ (p < 0.01), and yet more strongly with the novel metric θ*hydrogel volume (p < 0.001). With a median follow up of 14 months, no rectal toxicity >grade 2 was observed. Low grade rectal toxicity was observed in a third of men and resolved within 1 month of SBRT. Men who had these symptoms had higher rDmax 1 cc and smaller θ*hydrogel volume measurements. CONCLUSIONS: Optimal hydrogel placement occurs at prostate midgland, midline. The novel parameter θ*hydrogel volume describes a large proportion of rectum dosimetric benefit derived from hydrogel placement, and can be used to assess the learning curve phenomenon for hydrogel placement.


Subject(s)
Hydrogels/chemistry , Models, Statistical , Organs at Risk/radiation effects , Prostatic Neoplasms/surgery , Radiosurgery , Radiotherapy Planning, Computer-Assisted/methods , Rectum/radiation effects , Aged , Aged, 80 and over , Follow-Up Studies , Humans , Male , Middle Aged , Prognosis , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods
SELECTION OF CITATIONS
SEARCH DETAIL