Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-28809682

ABSTRACT

Air-coupled capacitive micromachined ultrasonic transducers (CMUTs) with annular cell geometry have recently been reported to have a promising transmit sensitivity. This paper reports three optimization schemes, which further improve the transmit sensitivity and also help achieve a reasonable comparison between the novel annular and conventional circular cells. Lumped element models of both cell types with laminate plate structures are presented. Based on these models, a design optimization flowchart was constructed to facilitate analytical optimization on the three schemes. Circular and annular CMUTs with a common 97-kHz natural resonance frequency were fabricated and characterized to verify the efficacy of the optimization principle. Using the optimization flowchart, annular and circular cells with frequencies ranging from 100 to 300 kHz were analytically optimized and then compared. The comparison results demonstrate that, given the same dc bias and ac excitation voltage, the output power density at the plate surface of the optimized annular cell is double that of the optimized circular cell. Additionally, when generating the same surface power density, an optimized annular cell requires either half the dc bias or half the ac excitation voltage of an optimized circular cell. This paper provides a practical optimization framework for CMUT cell design and demonstrates the superiority of annular cells for air-coupled applications.

2.
Ultrasonics ; 76: 19-27, 2017 04.
Article in English | MEDLINE | ID: mdl-28033499

ABSTRACT

Air-coupled capacitive micromachined ultrasonic transducers (CMUTs) based on annular cell geometry have recently been reported. Finite element analysis and experimental studies have demonstrated their significant improvement in transmit efficiency compared with the conventional circular-cell CMUTs. Extending the previous work, this paper proposed a lumped element model of annular-cell CMUTs. Explicit expressions of the resonance frequency, modal vector, and static displacement of a clamped annular plate under uniform pressure were first derived based on the plate theory and curve fitting method. The lumped model of an annular CMUT cell was then developed by adopting the average displacement as the spatial variable. Using the proposed model, the ratio of average-to-maximum displacement was derived to be 8/15. Experimental and simulation studies on a fabricated annular CMUT cell verified the effectiveness of the lumped model. The proposed model provides an effective and efficient way to analyze and design air-coupled annular-cell CMUTs.

3.
Ultrasonics ; 71: 152-160, 2016 09.
Article in English | MEDLINE | ID: mdl-27352025

ABSTRACT

A novel design of an air-coupled capacitive micromachined ultrasonic transducer (CMUT) with annular cell geometry (annular CMUT) is proposed. Finite element analysis shows that an annular cell has a ratio of average-to-maximum displacement (RAMD) of 0.52-0.58 which is 58-76% higher than that of a conventional circular cell. The increased RAMD leads to a larger volume displacement which results in a 48.4% improved transmit sensitivity and 127.3% improved power intensity. Single-cell annular CMUTs were fabricated with 20-µm silicon plates on 13.7-µm deep and 1.35-mm wide annular cavities using the wafer bonding technique. The measured RAMD of the fabricated CMUTs is 0.54. The resonance frequency was measured to be 94.5kHz at 170-V DC bias. The transmit sensitivity was measured to be 33.83Pa/V and 25.85Pa/V when the CMUT was excited by a continuous wave and a 20-cycle burst, respectively. The receive sensitivity at 170-V DC bias was measured to be 7.7mV/Pa for a 20-cycle burst, and 15.0mV/Pa for a continuous incident wave. The proposed annular CMUT design demonstrates a significant improvement in transmit efficiency, which is an important parameter for air-coupled ultrasonic transducers.

4.
Ultrasonics ; 54(8): 2072-80, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25066888

ABSTRACT

Row-column addressed arrays for ultrasonic non-destructive testing (NDT) applications are analyzed and demonstrated in this paper. Simulation and experimental results of a row-column addressed 32 by 32 capacitive micromachined ultrasonic transducer (CMUT) array are presented. The CMUT array, which was designed for medical imaging applications, has a center frequency of 5.3MHz. The CMUT array was used to perform C-scans on test objects with holes that have diameters of 1.0mm and 0.5mm. The array transducer has an aperture size of 4.8mm by 4.8mm, and it was used to scan an area of 4.0mm by 4.0mm. Compared to an N by N fully addressed 2-D array, a row-column addressed array of the same number of elements requires fewer (N instead of N(2)) pairs of interconnection and supporting electronic components such as pulsers and amplifiers. Even though the resulting field of view is limit by the aperture size, row-column addressed arrays and the row-column addressing scheme can be an alternative option of 2-D arrays for NDT applications.

5.
Article in English | MEDLINE | ID: mdl-22828846

ABSTRACT

We report the design and experimental results of a field-programmable gate array (FPGA)-based real-time ultrasound imaging system that uses a 16-element phased-array capacitive micromachined ultrasonic transducer fabricated using a fusion bonding process. The imaging system consists of the transducer, discrete analog components situated on a custom-made circuit board, the FPGA, and a monitor. The FPGA program consists of five functional blocks: a main counter, transmit and receive beamformer, receive signal pre-processing, envelope detection, and display. No dedicated digital signal processor or personal computer is required for the imaging system. An experiment is carried out to obtain the sector B-scan of a 4-wire target. The ultrasound imaging system demonstrates the possibility of an integrated system-in-a-package solution.


Subject(s)
Image Enhancement/instrumentation , Image Interpretation, Computer-Assisted/instrumentation , Information Storage and Retrieval/methods , Signal Processing, Computer-Assisted/instrumentation , Transducers , Ultrasonography/instrumentation , Computer-Aided Design , Electric Capacitance , Equipment Design , Equipment Failure Analysis , Miniaturization , Phantoms, Imaging
6.
Article in English | MEDLINE | ID: mdl-21693409

ABSTRACT

This paper presents characterization and initial imaging results of a 32 x 32 element two-dimensional capacitive micromachined ultrasonic transducer array. The devices are fabricated using a wafer bonding process in which both the insulation layer and the membrane are user-deposited silicon nitride. The transducers use a row-column addressing scheme to simplify the fabrication process and beamformer. By adjusting the number of rows and columns that are biased, the effective aperture of the transducer can be adjusted. This is significant because it permits imaging in the near-field of the transducer without the use of a lens. The effect on the transmit beam profile is demonstrated. The transducer has a center frequency of 5.9 MHz and a relative bandwidth of 110%. Images of horizontal and vertical wires are taken to demonstrate image resolution. A three-dimensional image of four pin heads is also demonstrated.


Subject(s)
Signal Processing, Computer-Assisted/instrumentation , Transducers , Ultrasonography/instrumentation , Electric Capacitance , Image Processing, Computer-Assisted , Microscopy, Electron, Scanning , Microtechnology