1.
Magn Reson Imaging ; 111: 47-56, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38513789

ABSTRACT

PURPOSE: Diffusion-weighted imaging (DWI) holds promise for image-guided radiotherapy (MRgRT) in prostate cancer. However, challenges persist due to image distortion, artifacts, and apparent diffusion coefficient (ADC) reproducibility issues. This study aimed to assess DWI image quality and ADC reproducibility on both a 1.5 T MR-simulator and a 1.5 T MR-Linac, employing measurements from both an ACR MRI phantom and prostate cancer patients undergoing MRgRT. METHODS: DW-MRI scans were conducted on 19 patients (mean age = 69 ± 8 years, with 23 MR-visible intra-prostatic lesions) and an ACR MRI phantom using a 1.5 T MR-simulator (b-values = 0, 800, 1400s/mm2) and a 1.5 T MR-Linac (b-values = 50, 500, 800 s/mm2). ADC homogeneity in the phantom was evaluated via 1D profile flatness (FL) in three directions. Image quality was assessed through qualitative 5-point Likert scale ratings and quantitative ADC and signal-to-noise ratio (SNR) measurements. Intra-observer reproducibility of image quality scores was evaluated using ICC(1, 2). Geometric distortion was measured by comparing landmark sizes on the ACR phantom against the ground truth. Mean ADC and reproducibility were assessed using Bland-Altman plots. RESULTS: Both MR-simulator and MR-Linac demonstrated high ADC homogeneity (FL > 87.5% - MR-simulator: 97.23 ± 0.62%, MR-Linac: 94.75 ± 0.62%, p < 0.05) in the phantom. Image quality scores revealed acceptable ratings (≥3) for capsule demarcation, image artifacts, and geometric distortion in patients. However, intra-prostatic lesions were barely discernible in b800 images for both MR-simulator (average score = 2.37 ± 1.33) and MR-Linac (average score = 2.16 ± 1.28). While MR-Linac DWI scans exhibited significantly more severe geometric distortion than MR-simulator scans (p < 0.01), most phantom measurements fell within the image in-plane resolution of 3 mm. Significant differences were noted in MR-simulator ADC (CTV: 1.20 ± 0.14 × 10-3 mm2/s (MR-simulator) vs 1.06 ± 0.10 × 10-3 mm2/s (MR-Linac); GTV: 1.05 ± 0.21 × 10-3 mm2/s vs 0.91 ± 0.16 × 10 mm2/s, all p < 0.05), with a small non-zero bias observed in the Bland-Altman analysis (CTV: 12.3%; GTV: 14.5%). CONCLUSION: The significantly larger MR-simulator ADC and the small non-zero bias hint at potential systematic differences in ADC values acquired from an MR-simulator and an MR-Linac, both at 1.5 T. Although acceptable ADC homogeneity was noted, caution is warranted in interpreting MR-Linac DWI images due to occasional severe artifacts. Further studies are essential to validate DWI and ADC as reliable imaging markers in prostate cancer MRgRT.


Subject(s)
Diffusion Magnetic Resonance Imaging , Phantoms, Imaging , Prostate , Prostatic Neoplasms , Radiotherapy, Image-Guided , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Diffusion Magnetic Resonance Imaging/methods , Reproducibility of Results , Aged , Radiotherapy, Image-Guided/methods , Prostate/diagnostic imaging , Middle Aged , Signal-To-Noise Ratio , Artifacts , Image Processing, Computer-Assisted/methods
2.
J Emerg Med ; 66(4): e467-e469, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38462393

ABSTRACT

BACKGROUND: Literature on systemic envenomation caused by tarantula bites, particularly from the Theraphosidae family, is relatively scarce. This case report provides a formal description of the first known instance of systemic envenomation caused by the Socotra Island Blue Baboon Tarantula (Monocentropus balfouri). CASE REPORT: In this case, a 23-year-old employee of an exotic pet shop suffered from perioral paresthesia, generalized muscle cramps, and rhabdomyolysis because of a Monocentropus balfouri bite. His symptoms were successfully relieved with oral benzodiazepines. EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case highlights the potential for serious complications resulting from the bite of Monocentropus balfouri, a species gaining popularity among global exotic pet collectors.


Subject(s)
Rhabdomyolysis , Spider Bites , Spiders , Animals , Humans , Young Adult , Adult , Muscle Cramp , Spider Bites/complications , Paresthesia/etiology , Spasm , Rhabdomyolysis/complications
3.
World J Urol ; 42(1): 97, 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38393414

ABSTRACT

BACKGROUND AND PURPOSE: This prospective study aimed to investigate adaptive magnetic resonance (MR)-guided stereotactic body radiation therapy (MRgSBRT) with rectal spacer for localized prostate cancer (PC) and report 1-year clinical outcomes. MATERIALS AND METHODS: Thirty-four consecutive patients with low- to high-risk localized PC that underwent 5-fraction adaptive MRgSBRT with rectal spacer were enrolled. The dosimetric comparison was performed on a risk- and age-matched cohort treated with MRgSBRT but without a spacer at a similar timepoint. Clinician-reported outcomes were based on Common Terminology Criteria for Adverse Events. Patient-reported outcomes were based on the Expanded Prostate Cancer Index Composite (EPIC) questionnaire at baseline, acute (1-3 months), subacute (4-12 months), and late (> 12 months) phases. RESULTS: The median follow-up was 390 days (range 28-823) and the median age was 70 years (range 58-82). One patient experienced rectal bleeding soon after spacer insertion that subsided before MRgSBRT. The median distance between the midline of the prostate midgland and the rectum after spacer insertion measured 7.8 mm (range 2.6-15.3), and the median length of the spacer was 45.9 mm (range 16.8-62.9) based on T2-weighted MR imaging. The use of spacer resulted in significant improvements in target coverage (V100% > 95% = 98.6% [range 93.4-99.8] for spacer vs. 97.8% [range 69.6-99.7] for non-spacer) and rectal sparing (V95% < 3 cc = 0.7 cc [range 0-4.6] for spacer vs. 4.9 cc [range 0-12.5] for non-spacer). Nine patients (26.5%) experienced grade 1 gastrointestinal toxicities, and no grade ≥ 2 toxicities were observed. During the 1-year follow-up period, EPIC scores for the bowel domain remained stable and were the highest among all other domains. CONCLUSIONS: MRgSBRT with rectal spacer for localized PC showed exceptional tolerability with minimal gastrointestinal toxicities and satisfactory patient-reported outcomes. Improvements in dosimetry, rectal sparing, and target coverage were achieved with a rectal spacer. Randomized trials are warranted for further validation.


Subject(s)
Prostatic Neoplasms , Rectum , Male , Humans , Middle Aged , Aged , Aged, 80 and over , Prospective Studies , Radiotherapy Dosage , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy
4.
Mol Cancer Ther ; 23(2): 127-138, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37816503

ABSTRACT

The cluster of differentiation 38 (CD38) is a well-validated target for treating multiple myeloma. Although anti-CD38 mAbs have demonstrated outstanding initial responses in patients with multiple myeloma, nearly all patients eventually develop resistance and relapse. In addition, currently approved CD38 targeting therapies have failed to show monotherapy efficacy in lymphomas, where CD38 expression is present but at lower levels. To effectively target CD38 on tumor cells, we generated an antibody-dependent cellular cytotoxicity (ADCC) enhanced bispecific CD38 x intercellular cell adhesion molecule 1 (ICAM-1) antibody, VP301. This bispecific antibody targets unique epitopes on CD38 and ICAM-1 on tumor cells with reduced red blood cell binding compared with the benchmark CD38 antibody daratumumab. VP301 demonstrated potent ADCC and antibody-dependent cellular phagocytosis activities on a selected set of myeloma and lymphoma cell lines even those with low CD38 expression. In an ex vivo drug sensitivity assay, we observed responses to VP301 in multiple myeloma primary samples from relapsed/refractory patients. Moreover, VP301 demonstrated potent tumor inhibition activities in in vivo myeloma and lymphoma models. Interestingly, combination of VP301 with the immunomodulatory drug, lenalidomide, led to synergistic antitumor growth activity in an in vivo efficacy study. In conclusion, the CD38 x ICAM-1 bispecific antibody VP301 demonstrated promising efficacy and specificity toward CD38+ and ICAM-1+ tumor cells and represents a novel approach for treating multiple myeloma and lymphoma.


Subject(s)
Antibodies, Bispecific , Lymphoma , Multiple Myeloma , Humans , ADP-ribosyl Cyclase 1/metabolism , Antibodies, Bispecific/pharmacology , Antibodies, Bispecific/therapeutic use , Cell Line, Tumor , Intercellular Adhesion Molecule-1/metabolism , Multiple Myeloma/pathology
5.
Med Phys ; 51(2): 1244-1262, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37665783

ABSTRACT

BACKGROUND: The use of synthetic computed tomography (CT) for radiotherapy treatment planning has received considerable attention because of the absence of ionizing radiation and close spatial correspondence to source magnetic resonance (MR) images, which have excellent tissue contrast. However, in an MR-only environment, little effort has been made to examine the quality of synthetic CT images without using the original CT images. PURPOSE: To estimate synthetic CT quality without referring to original CT images, this study established the relationship between synthetic CT uncertainty and Bayesian uncertainty, and proposed a new Bayesian deep network for generating synthetic CT images and estimating synthetic CT uncertainty for MR-only radiotherapy treatment planning. METHODS AND MATERIALS: A novel deep Bayesian network was formulated using probabilistic network weights. Two mathematical expressions were proposed to quantify the Bayesian uncertainty of the network and synthetic CT uncertainty, which was closely related to the mean absolute error (MAE) in Hounsfield Unit (HU) of synthetic CT. These uncertainties were examined to demonstrate the accuracy of representing the synthetic CT uncertainty using a Bayesian counterpart. We developed a hybrid Bayesian architecture and a new data normalization scheme, enabling the Bayesian network to generate both accurate synthetic CT and reliable uncertainty information when probabilistic weights were applied. The proposed method was evaluated in 59 patients (13/12/32/2 for training/validation/testing/uncertainty visualization) diagnosed with prostate cancer, who underwent same-day pelvic CT- and MR-acquisitions. To assess the relationship between Bayesian and synthetic CT uncertainties, linear and non-linear correlation coefficients were calculated on per-voxel, per-tissue, and per-patient bases. For accessing the accuracy of the CT number and dosimetric accuracy, the proposed method was compared with a commercially available atlas-based method (MRCAT) and a U-Net conditional-generative adversarial network (UcGAN). RESULTS: The proposed model exhibited 44.33 MAE, outperforming UcGAN 52.51 and MRCAT 54.87. The gamma rate (2%/2 mm dose difference/distance to agreement) of the proposed model was 98.68%, comparable to that of UcGAN (98.60%) and MRCAT (98.56%). The per-patient and per-tissue linear correlation coefficients between the Bayesian and synthetic CT uncertainties ranged from 0.53 to 0.83, implying a moderate to strong linear correlation. Per-voxel correlation coefficients varied from -0.13 to 0.67 depending on the regions-of-interest evaluated, indicating tissue-dependent correlation. The R2 value for estimating MAE solely using Bayesian uncertainty was 0.98, suggesting that the uncertainty of the proposed model was an ideal candidate for predicting synthetic CT error, without referring to the original CT. CONCLUSION: This study established a relationship between the Bayesian model uncertainty and synthetic CT uncertainty. A novel Bayesian deep network was proposed to generate a synthetic CT and estimate its uncertainty. Various metrics were used to thoroughly examine the relationship between the uncertainties of the proposed Bayesian model and the generated synthetic CT. Compared with existing approaches, the proposed model showed comparable CT number and dosimetric accuracies. The experiments showed that the proposed Bayesian model was capable of producing accurate synthetic CT, and was an effective indicator of the uncertainty and error associated with synthetic CT in MR-only workflows.


Subject(s)
Radiotherapy, Intensity-Modulated , Male , Humans , Bayes Theorem , Uncertainty , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted/methods
6.
Neuroimaging Clin N Am ; 33(4): 643-659, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37741663

ABSTRACT

In this article, we will describe relevant anatomy and imaging findings of extraocular and orbital rim pathologic conditions. We will highlight important clinical and imaging pearls that help in differentiating these lesions from one another, and provide a few practical tips for challenging cases.

7.
J Thorac Dis ; 15(7): 3699-3707, 2023 Jul 31.
Article in English | MEDLINE | ID: mdl-37559646

ABSTRACT

Background: In early 2022, there was a sudden surge of patients infected by the Omicron variant of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in Hong Kong (HK), resulting in 9,163 deaths as of 29 May 2022. Many of the local population had not been vaccinated before this wave. The number of patients who developed coronavirus disease 2019 (COVID-19) related respiratory failure outnumbered the capacity of intensive care unit (ICU) beds. Some of these patients had to be supported with high flow nasal cannula (HFNC) therapy outside ICU setting. HK was in crisis situation. The primary objective of this study is to assess the 28-day mortality of this group of patients. The secondary objective is to explore any predictors of non-survivors to help clinical decision-making in future crisis. Methods: This is a retrospective observational study of patients suffering from COVID-19 related respiratory failure who received HFNC therapy in general medical wards of two hospitals during the period of 17 Mar to 30 Apr 2022. Survival and risk factors were reviewed. Results: Forty-nine patients were recruited. Twenty-six patients (53%) survived at 28-day after initiation of HFNC support. Three clinical parameters were found to be significantly associated with mortality at 28-day: (I) SpO2/FiO2 (SF) ratio <160 at 48 hours; (II) SF ratio <191 at 72 hours; (III) serial SF ratio at 48 or 72 hours showing no improvement over that at the time of initiation of HFNC therapy. Conclusions: Use of HFNC outside ICU setting showed benefit to patients suffering from COVID-19 related acute hypoxemic respiratory failure (AHRF). Serial SF ratio monitoring at 48 and 72 hours after therapy initiation might serve as predictors of outcome and thus guide clinical decision-making for medical resource allocation in outbreak situation.

8.
J Cancer Res Clin Oncol ; 149(2): 841-850, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35199189

ABSTRACT

PURPOSE: To analyze and characterize the online plan adaptation of 1.5T magnetic resonance-guided stereotactic body radiotherapy (MRgSBRT) of prostate cancer (PC). METHODS: PC patients (n = 107) who received adaptive 1.5 Tesla MRgSBRT were included. Online plan adaptation was implemented by either the adapt-to-position (ATP) or adapt-to-shape (ATS) methods. Patients were assigned to the ATS group if they underwent ≥ 1 ATS fraction (n = 51); the remainder were assigned to the ATP group (n = 56). The online plan adaptation records of 535 (107 × 5) fractions were retrospectively reviewed. Rationales for ATS decision-making were determined and analyzed using predefined criteria. Statistics of ATS fractions were summarized. Associations of patient characteristics and clinical factors with ATS utilization were investigated. RESULTS: There were 87 (16.3%) ATS fractions and 448 ATP fractions (83.7%). The numbers of ATS adoptions in fractions 1-5 were 29 (29/107, 27.1%), 18 (16.8%), 15 (14.0%), 16 (15.0%), and 9 (8.4%), respectively, with significant differences in adoption frequency between fractions (p = 0.007). Other baseline patient characteristics and clinical factors were not significantly associated with ATS classification (all p > 0.05). Underlying criteria for the determination of ATS implementation comprised anatomical changes (77 fractions in 50 patients) and discrete multiple targets (15 fractions in 3 patients). No ATS utilization was determined using dosimetric or online quality assurance criteria. CONCLUSIONS: This study contributes to facilitating the establishment of a standardized protocol for online MR-guided adaptive radiotherapy in PC.


Subject(s)
Prostatic Neoplasms , Radiosurgery , Radiotherapy, Image-Guided , Male , Humans , Radiosurgery/methods , Retrospective Studies , Radiotherapy Planning, Computer-Assisted/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiotherapy, Image-Guided/methods , Magnetic Resonance Spectroscopy , Adenosine Triphosphate , Radiotherapy Dosage , Magnetic Resonance Imaging/methods
9.
Cancers (Basel) ; 14(14)2022 Jul 18.
Article in English | MEDLINE | ID: mdl-35884553

ABSTRACT

Background: Conventionally fractionated whole-pelvic nodal radiotherapy (WPRT) improves clinical outcome compared to prostate-only RT in high-risk prostate cancer (HR-PC). MR-guided stereotactic body radiotherapy (MRgSBRT) with concomitant WPRT represents a novel radiotherapy (RT) paradigm for HR-PC, potentially improving online image guidance and clinical outcomes. This study aims to report the preliminary clinical experiences and treatment outcome of 1.5 Tesla adaptive MRgSBRT with concomitant WPRT in HR-PC patients. Materials and methods: Forty-two consecutive HR-PC patients (72.5 ± 6.8 years) were prospectively enrolled, treated by online adaptive MRgSBRT (8 Gy(prostate)/5 Gy(WPRT) × 5 fractions) combined with androgen deprivation therapy (ADT) and followed up (median: 251 days, range: 20−609 days). Clinical outcomes were measured by gastrointestinal (GI) and genitourinary (GU) toxicities according to the Common Terminology Criteria for Adverse Events (CTCAE) Scale v. 5.0, patient-reported quality of life (QoL) with EPIC (Expanded Prostate Cancer Index Composite) questionnaire, and prostate-specific antigen (PSA) responses. Results: All MRgSBRT fractions achieved planning objectives and dose specifications of the targets and organs at risk, and they were successfully delivered. The maximum cumulative acute GI/GU grade 1 and 2 toxicity rates were 19.0%/81.0% and 2.4%/7.1%, respectively. The subacute (>30 days) GI/GU grade 1 and 2 toxicity rates were 21.4%/64.3% and 2.4%/2.4%, respectively. No grade 3 toxicities were reported. QoL showed insignificant changes in urinary, bowel, sexual, and hormonal domain scores during the follow-up period. All patients had early post-MRgSBRT biochemical responses, while biochemical recurrence (PSA nadir + 2 ng/mL) occurred in one patient at month 18. Conclusions: To our knowledge, this is the first prospective study that showed the clinical outcomes of MRgSBRT with concomitant WPRT in HR-PC patients. The early results suggested favorable treatment-related toxicities and encouraging patient-reported QoLs, but long-term follow-up is needed to confirm our early results.

10.
Vis Comput Ind Biomed Art ; 5(1): 10, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35359245

ABSTRACT

Radiomics has increasingly been investigated as a potential biomarker in quantitative imaging to facilitate personalized diagnosis and treatment of head and neck cancer (HNC), a group of malignancies associated with high heterogeneity. However, the feature reliability of radiomics is a major obstacle to its broad validity and generality in application to the highly heterogeneous head and neck (HN) tissues. In particular, feature repeatability of radiomics in magnetic resonance imaging (MRI) acquisition, which is considered a crucial confounding factor of radiomics feature reliability, is still sparsely investigated. This study prospectively investigated the acquisition repeatability of 93 MRI radiomics features in ten HN tissues of 15 healthy volunteers, aiming for potential magnetic resonance-guided radiotherapy (MRgRT) treatment of HNC. Each subject underwent four MRI acquisitions with MRgRT treatment position and immobilization using two pulse sequences of 3D T1-weighed turbo spin-echo and 3D T2-weighed turbo spin-echo on a 1.5 T MRI simulator. The repeatability of radiomics feature acquisition was evaluated in terms of the intraclass correlation coefficient (ICC), whereas within-subject acquisition variability was evaluated in terms of the coefficient of variation (CV). The results showed that MRI radiomics features exhibited heterogeneous acquisition variability and uncertainty dependent on feature types, tissues, and pulse sequences. Only a small fraction of features showed excellent acquisition repeatability (ICC > 0.9) and low within-subject variability. Multiple MRI scans improved the accuracy and confidence of the identification of reliable features concerning MRI acquisition compared to simple test-retest repeated scans. This study contributes to the literature on the reliability of radiomics features with respect to MRI acquisition and the selection of reliable radiomics features for use in modeling in future HNC MRgRT applications.

11.
Quant Imaging Med Surg ; 12(2): 1585-1607, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35111651

ABSTRACT

Magnetic resonance guided radiotherapy (MRgRT), enabled by the clinical introduction of the integrated MRI and linear accelerator (MR-LINAC), is a novel technique for prostate cancer (PCa) treatment, promising to further improve clinical outcome and reduce toxicity. The role of prostate MRI has been greatly expanded from the traditional PCa diagnosis to also PCa screening, treatment and surveillance. Diagnostic prostate MRI has been relatively familiar in the community, particularly with the development of Prostate Imaging - Reporting and Data System (PI-RADS). But, on the other hand, the use of MRI in the emerging clinical practice of PCa MRgRT, which is substantially different from that in PCa diagnosis, has been so far sparsely presented in the medical literature. This review attempts to give a comprehensive overview of MRI acquisition techniques currently used in the clinical workflows of PCa MRgRT, from treatment planning to online treatment guidance, in order to promote MRI practice and research for PCa MRgRT. In particular, the major differences in the MRI acquisition of PCa MRgRT from that of diagnostic prostate MRI are demonstrated and explained. Limitations in the current MRI acquisition for PCa MRgRT are analyzed. The future developments of MRI in the PCa MRgRT are also discussed.

12.
Asia Pac J Clin Oncol ; 18(5): e369-e377, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35073460

ABSTRACT

PURPOSE: To assess the image quality and delineation value of compressed sensing (CS)-accelerated 3D T2W turbo-spin-echo (TSE) sequence for radiotherapy treatment planning (RTP) of prostate cancer. METHODS: An optimized CS-accelerated 3D-T2W-TSE was determined by volunteer imaging and applied for clinical RTP-MRI. This optimized CS-accelerated planning MRI and the standardized adaptive MRI acquired at 1.5T were retrospectively analyzed in 26 prostate cancer patients who were to receive MR-guided radiotherapy. Signal-to-noise ratio (SNR) and relative contrast ratio (CR) were quantitatively assessed. Image quality and artifacts were qualitatively assessed using a five-point scale rating. Delineation value in the prostate and organs-at-risk (OARs) was also rated and compared. Wilcoxon signed-rank test was used for SNR, relative CR, and rating comparisons. The interobserver rating agreement was evaluated by percent agreement. RESULTS: Significantly better SNR and relative CR in the prostate, rectum, bowel, penis, and penile bulb, while significantly worse in the cauda equina, were observed on the planning MRI. Significantly better ratings of image quality and artifacts were given to the planning MRI, with much less Gibbs ringing and reconstruction artifacts. Significantly better delineation value rating was achieved on the planning MRI in the prostate, seminal vesicle, rectum, penis, penile bulb, and testes, while significantly worse in the cauda equina. A strong to almost perfect interobserver rating agreement was obtained. CONCLUSION: This study suggested that CS acceleration is applicable and valuable in prostate RTP-MRI. CS-accelerated 3D-T2W-TSE images should benefit the delineation of prostate and many OARs.


Subject(s)
Magnetic Resonance Imaging , Prostatic Neoplasms , Acceleration , Artifacts , Humans , Magnetic Resonance Imaging/methods , Male , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Retrospective Studies
13.
J Cancer Res Clin Oncol ; 148(7): 1749-1759, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34363123

ABSTRACT

PURPOSE: Performance of 3D-T1W-TSE has been proven superior to 3D-MP-GRE at 3 T on brain metastases (BM) contrast-enhanced (CE) MRI. However, its performance at 1.5 T is largely unknown and sparsely reported. This study aims to assess image quality, lesion detectability and conspicuity of 1.5 T 3D-T1W-TSE on planning MRI of frameless BM radiotherapy. METHODS: 94 BM patients to be treated by frameless brain radiotherapy were scanned using 3D-T1W-TSE with immobilization on multi-vendor 1.5 T MRI-simulators. BMs were jointly diagnosed by 4 reviewers. Enhanced lesion conspicuity was quantitatively assessed by calculating contrast ratio (CR) and contrast-to-noise ratio (CNR). Signal-to-noise ratio (SNR) reduction of white matter due to the use of flexible coil was assessed. Lesion detectability and conspicuity were compared between 1.5 T planning MRI and 3 T diagnostic MRI by an oncologist and a radiologist in 10 patients. RESULTS: 497 BMs were jointly diagnosed. The CR and CNR were 75.2 ± 39.9% and 14.2 ± 8.1, respectively. SNR reduced considerably from 31.7 ± 8.3 to 21.9 ± 5.4 with the longer distance to coils. 3 T diagnostic MRI and 1.5 T planning MRI yielded exactly the same detection of 84 BMs. Qualitatively, lesion conspicuity at 1.5 T was not inferior to that at 3 T. Quantitatively, lower brain SNR and lesion CNR were found at 1.5 T, while lesion CR at 1.5 T was highly comparable to that at 3 T. CONCLUSION: 1.5 T 3D-T1W-TSE planning MRI of frameless BM radiotherapy was comprehensively assessed. Highly comparable BM detectability and conspicuity were achieved by 1.5 T planning MRI compared to 3 T diagnostic MRI. 1.5 T 3D-T1W-TSE should be valuable for frameless brain radiotherapy planning.


Subject(s)
Brain Neoplasms , Radiation Oncology , Brain , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/radiotherapy , Contrast Media , Humans , Magnetic Resonance Imaging/methods
14.
Cancers (Basel) ; 13(19)2021 Sep 28.
Article in English | MEDLINE | ID: mdl-34638348

ABSTRACT

BACKGROUND: Magnetic resonance-guided stereotactic body radiotherapy (MRgSBRT) offers the potential for achieving better prostate cancer (PC) treatment outcomes. This study reports the preliminary clinical results of 1.5T MRgSBRT in localized PC, based on both clinician-reported outcome measurement (CROM) and patient-reported outcome measurement (PROM). METHODS: Fifty-one consecutive localized PC patients were prospectively enrolled with a median follow-up of 199 days. MRgSBRT was delivered in five fractions of 7.25-8 Gy with daily online adaptation. Clinician-reported gastrointestinal (GI) and genitourinary (GU) adverse events based on the Common Terminology Criteria for Adverse Events (CTCAE) Scale v. 5.0 were assessed. The Expanded Prostate Cancer Index Composite Questionnaire was collected at baseline, 1 month, and every 3 months thereafter. Serial prostate-specific antigen measurements were longitudinally recorded. RESULTS: The maximum cumulative clinician-reported grade ≥ 2 acute GU and GI toxicities were 11.8% (6/51) and 2.0% (1/51), respectively, while grade ≥ 2 subacute GU and GI toxicities were 2.3% (1/43) each. Patient-reported urinary, bowel, and hormonal domain summary scores were reduced at 1 month, then gradually returned to baseline levels, with the exception of the sexual domain. Domain-specific subscale scores showed similar longitudinal changes. All patients had early post-MRgSBRT biochemical responses. CONCLUSIONS: The finding of low toxicity supports the accumulation of clinical evidence for 1.5T MRgSBRT in localized PC.

15.
Quant Imaging Med Surg ; 11(10): 4431-4460, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34603997

ABSTRACT

Radiomics research is rapidly growing in recent years, but more concerns on radiomics reliability are also raised. This review attempts to update and overview the current status of radiomics reliability research in the ever expanding medical literature from the perspective of a single reliability metric of intraclass correlation coefficient (ICC). To conduct this systematic review, Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. After literature search and selection, a total of 481 radiomics studies using CT, PET, or MRI, covering a wide range of subject and disease types, were included for review. In these highly heterogeneous studies, feature reliability to image segmentation was much more investigated than reliability to other factors, such as image acquisition, reconstruction, post-processing, and feature quantification. The reported ICCs also suggested high radiomics feature reliability to image segmentation. Image acquisition was found to introduce much more feature variability than image segmentation, in particular for MRI, based on the reported ICC values. Image post-processing and feature quantification yielded different levels of radiomics reliability and might be used to mitigate image acquisition-induced variability. Some common flaws and pitfalls in ICC use were identified, and suggestions on better ICC use were given. Due to the extremely high study heterogeneities and possible risks of bias, the degree of radiomics feature reliability that has been achieved could not yet be safely synthesized or derived in this review. More future researches on radiomics reliability are warranted.

16.
Quant Imaging Med Surg ; 11(5): 1870-1887, 2021 May.
Article in English | MEDLINE | ID: mdl-33936971

ABSTRACT

BACKGROUND: MRI pulse sequences and imaging parameters substantially influence the variation of MRI radiomics features, thus impose a critical challenge on MRI radiomics reproducibility and reliability. This study aims to prospectively investigate the impact of various imaging parameters on MRI radiomics features in a 3D T2-weighted (T2W) turbo-spin-echo (TSE) pulse sequence for MR-guided-radiotherapy (MRgRT). METHODS: An anthropomorphic phantom was scanned using a 3D-T2W-TSE MRgRT sequence at 1.5T under a variety of acquisition imaging parameter changes. T1 and T2 relaxation times of the phantom were also measured. 93 first-order and texture radiomics features in the original and 14 transformed images, yielding 1,395 features in total, were extracted from 10 volumes-of-interest (VOIs). The percentage deviation (d%) of radiomics feature values from the baseline values and intra-class correlation coefficient (ICC) with the baseline were calculated. Robust radiomics features were identified based on the excellent agreement of radiomics feature values with the baseline, i.e., the averaged d% <5% and ICC >0.90 in all VOIs for all imaging parameter variations. RESULTS: The radiomics feature values changed considerably but to different degrees with different imaging parameter adjustments, in the ten VOIs. The deviation d% ranged from 0.02% to 321.3%, with a mean of 12.5% averaged for all original features in all ten VOIs. First-order and GLCM features were generally more robust to imaging parameters than other features in the original images. There were also significantly different radiomics feature values (ANOVA, P<0.001) between the original and the transformed images, exhibiting quite different robustness to imaging parameters. 330 out of 1395 features (23.7%) robust to imaging parameters were identified. GLCM and GLSZM features had the most (42.5%, 153/360) and least (3.8%, 9/240) robust features in the original and transformed images, respectively. CONCLUSIONS: This study helps better understand the quantitative dependence of radiomics feature values on imaging parameters in a 3D-T2W-TSE sequence for MRgRT. Imaging parameter heterogeneity should be considered as a significant source of radiomics variability and uncertainty, which must be well harmonized for reliable clinical use. The identified robust features to imaging parameters are helpful for the pre-selection of radiomics features for reliable radiomics modeling.

17.
BMC Palliat Care ; 20(1): 48, 2021 Mar 23.
Article in English | MEDLINE | ID: mdl-33757502

ABSTRACT

BACKGROUND: Due to the ageing population in Hong Kong, the importance and need of palliative care and end-of-life (EOL) care are coming under the spotlight. The objectives of this study were to evaluate the attitudes of emergency doctors in providing palliative and EOL care in Hong Kong, and to investigate the educational needs of emergency doctors in these areas. METHODS: A questionnaire was used to study the attitudes of ED doctors of six different hospitals in Hong Kong. The questionnaire recorded the attitudes of the doctors towards the role of palliative and EOL care in EDs, the specific obstacles faced, their comfort level and further educational needs in providing such care. The attitudes of emergency doctors of EDs with EOL care services were compared with those of EDs without such services. RESULTS: In total, 145 emergency doctors completed the questionnaire, of which 60 respondents were from EDs with EOL care services. A significant number of participants recognized that the management of the dying process was essential in ED. Providing palliative and EOL care is also accepted as an important competence and responsibility, but the role and priority of palliative and EOL care in ED are uncertain. Lack of time and access to palliative care specialists/ teams were the major barriers. Doctors from EDs with EOL care services are more comfortable in providing such care and discuss it with patients and their relatives. Further educational needs were identified, including the management of physical complaints, communication skills, and EOL care ethics. CONCLUSIONS: The study identified obstacles in promoting palliative and EOL care in the EDs Hong Kong. With the combination of elements of routine ED practice and a basic palliative medicine skill set, it would promote the development of palliative and EOL care in Emergency Medicine in the future.


Subject(s)
Palliative Care , Terminal Care , Attitude of Health Personnel , Cross-Sectional Studies , Hong Kong , Humans , Self Report
18.
Magn Reson Med ; 85(6): 3434-3446, 2021 06.
Article in English | MEDLINE | ID: mdl-33404129

ABSTRACT

PURPOSE: To prospectively investigate the impact of image reconstruction on MRI radiomics features. METHODS: An anthropomorphic phantom was scanned at 1.5 T using a standardized sequence for MR-guided radiotherapy under SENSE and compressed-SENSE reconstruction settings. A total of 93 first-order and texture radiomics features in 10 volumes of interest were assessed based on (1) accuracy measured by the percentage deviation from the reference, (2) robustness on reconstruction in all volumes of interest measured by the intraclass correlation coefficient, and (3) repeatability measured by the coefficient of variance over the repetitive acquisitions. Finally, reliable and unreliable radiomics features were comprehensively determined based on their accuracy, robustness, and repeatability. RESULTS: Better accuracy and robustness of the radiomics features were achieved under SENSE than compressed-SENSE reconstruction. The feature accuracy under SENSE reconstruction was more affected by acceleration factor than direction, whereas under compressed-SENSE reconstruction, accuracy was substantially impacted by the increasing denoising levels. Feature repeatability was dependent more on feature types than on reconstruction. A total of 45 reliable features and 13 unreliable features were finally determined for SENSE, compared with 22 reliable and 26 unreliable features for compressed SENSE. First-order and gray-level co-occurrence matrix features were generally more reliable than other features. CONCLUSION: Radiomics features could be substantially affected by MRI reconstruction, so precautions need to be taken regarding their reliability for clinical use. This study helps the guidance of the preselection of reliable radiomics features and the preclusion of unreliable features in MR-guided radiotherapy.


Subject(s)
Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Phantoms, Imaging , Reproducibility of Results
19.
Med Phys ; 48(3): 1239-1249, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33370474

ABSTRACT

PURPOSE: The purpose of this study was to quantitatively assess the longitudinal acquisition repeatability of MRI radiomics features in a three-dimensional (3D) T1-weighted (T1W) TSE sequence via a well-controlled prospective phantom study. METHODS: Thirty consecutive daily datasets of an ACR-MRI phantom were acquired on two 1.5T MRI simulators using a 3D T1W TSE sequence. Images were blindly segmented by two observers. Post-acquisition processing was minimized but an intensity discretization (fixed bin size of 25). One hundred and one radiomics features (shape n = 12; first order n = 16; texture n = 73) were extracted. Longitudinal repeatability of each feature was evaluated by Pearson correlation and coefficient of variance (CV68% ). Interobserver feature value agreement was also quantified using intraclass correlation coefficient (ICC) and Bland-Altman analysis. A most repeatable radiomics feature set on both scanners was determined by feature coefficient of variance (CV68% <5%), ICC (>0.75), and the ratio of the interobserver difference to the interobserver mean δ<5%. RESULTS: No trend of radiomics feature value changed with time. Longitudinal feature repeatability CV68% ranged 0.01-38.60% (mean/median: 12.5%/9.9%), and 0.01-40.47%, (8.49%/7.34%) on the scanners A and B. Shape features exhibited significantly better repeatability than first-order and texture features (all P < 0.01). Significant longitudinal repeatability difference was observed in texture features (P < 0.001) between the two scanners, but not in shape and first-order features (P > 0.30). First-order and texture features had smaller interobserver-dependent variation than acquisition-dependent variation. They also showed good interobserver agreement on both scanners (A:ICC = 0.80 ± 0.23; B:ICC = 0.80 ± 0.22), independent of acquisition repeatability. The repeatable radiomics features in common on both scanners, including 12 shape features, 0 first-order features, and 3 texture features, were determined as the most repeatable MRI radiomics feature set. CONCLUSIONS: Radiomics features exhibited heterogeneous longitudinal repeatability, while the shape features were the most repeatable, in this phantom study with a 3D T1W TSE acquisition. The most repeatable radiomics feature set derived in this study should be helpful for the selection of reliable radiomics features in the future clinical use.


Subject(s)
Magnetic Resonance Imaging , Humans , Observer Variation , Phantoms, Imaging , Prospective Studies
20.
Radiol Case Rep ; 15(11): 2237-2240, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32952762

ABSTRACT

In superior vena cava obstruction, one of the signs on computed tomography is an arterially enhancing pseudolesion in segment IV adjacent to the falciform ligament due to collateral flow via the veins of Sappey, sometimes termed the "lightbulb sign." We describe a case where venoplasty was performed to restore flow in superior vena cava with disappearance of the pseudolesion on subsequent computed tomography, thus "switching off the lightbulb."