Nanomaterials (Basel) ; 11(2)2021 Feb 09.
Article in English | MEDLINE | ID: mdl-33572253

ABSTRACT

Square-shaped or rectangular nanoparticles (NPs) of lanthanum oxide (LaOx) were synthesized and layered by convective self-assembly to demonstrate an analog memristive device in this study. Along with non-volatile analog memory effect, selection diode property could be co-existent without any implementation of heterogeneous multiple stacks with ~1 µm thick LaOx NPs layer. Current-voltage (I-V) behavior of the LaOx NPs resistive switching (RS) device has shown an evolved current level with memristive behavior and additional rectification functionality with threshold voltage. The concurrent memristor and diode type selector characteristics were examined with electrical stimuli or spikes for the duration of 10-50 ms pulse biases. The pulsed spike increased current levels at a read voltage of +0.2 V sequentially along with ±7 V biases, which have emulated neuromorphic operation of long-term potentiation (LTP). This study can open a new application of rare-earth LaOx NPs as a component of neuromorphic synaptic device.

2.
Biosens Bioelectron ; 159: 112186, 2020 Jul 01.
Article in English | MEDLINE | ID: mdl-32364939

ABSTRACT

In this study, high electron mobility transistor (HEMT) device was used as an immuno biosensor to measure concentration of a stress hormone, cortisol, by using selective binding on cortisol monoclonal antibody (c-Mab). Also, the HEMT sensor was enhanced in its sensitivity through light illumination to generate photocurrent. The optical pumping could assist the biosensor to discriminate more detailed change, which could result in an increment of limit of detection (LOD) to 1.0 pM cortisol level. It was the lowest level of detection with semiconductor device-based cortisol biosensors and the enhancement of surface potential sensitivity was induced by laser light (532 nm). Output current amplificated by photocurrent was higher than dark original current at about 3.39% when gate voltage is applied with -3 V. Since the device could be applied to not only standard cortisol solution but also real human salivary sample, it is expected to apply for in vitro direct diagnosis of point-of-care test (POCT).


Subject(s)
Aluminum Compounds , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Gallium , Hydrocortisone/analysis , Lasers , Transistors, Electronic , Aluminum Compounds/chemistry , Gallium/chemistry , Humans , Microfluidic Analytical Techniques/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...