Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-39189971

ABSTRACT

Gastric peristalsis is governed by electrical "slow waves" generally assumed to travel from proximal to distal stomach (antegrade propagation) in symmetric rings. While alternative slow wave patterns have been correlated with gastric disorders, their mechanisms and how they alter contractions remain understudied. Optical electromechanical mapping, a developing field in cardiac electrophysiology, images electrical and mechanical physiology simultaneously. Here, we translate this technology to the in-vivo porcine stomach. Stomachs were surgically exposed and a fluorescent dye (di-4-ANEQ(F)PTEA) that transduces the membrane potential (Vm) was injected through the right gastroepiploic artery. Fluorescence was excited by LEDs and imaged with one or two 256x256 pixel cameras. Motion artifact was corrected using a marker-based motion tracking method and excitation ratiometry, which cancels common-mode artifact. Tracking marker displacement also enabled gastric deformation to be measured. We validated detection of electrical activation and Vm morphology against alternative non-optical technologies. Non-antegrade slow waves and propagation direction differences between the anterior and posterior stomach were commonly present in our data. However, sham experiments suggest they were a feature of the animal preparation and not an artifact of optical mapping. In experiments to demonstrate the method's capabilities, we found that repolarization did not always follow at a fixed time behind activation "wavefronts," which could be a factor in dysrhythmia. Contraction strength and the latency between electrical activation and contraction differed between antegrade and non-antegrade propagation. In conclusion, optical electromechanical mapping, which simultaneously images electrical and mechanical activity, enables novel questions regarding normal and abnormal gastric physiology to be explored.

2.
Article in English | MEDLINE | ID: mdl-38082915

ABSTRACT

Cardiac optical mapping has traditionally been performed in ex-vivo, motion-arrested hearts. Recently, in-situ cardiac optical mapping has been made possible by both motion correction techniques and long-wavelength voltage sensitive dyes (VSDs). However, VSDs have been observed to wash out quickly from blood-perfused in-situ hearts. In this study, we evaluate the performance of a newly developed VSD, di-5-ANEQ(F)PTEA, relative to an earlier VSD, di-4-ANEQ(F)PTEA. We find that di-5-ANEQ(F)PTEA persists over 3 times longer, produces improved signal-to-noise ratio, and does not prolong loading unacceptably.Clinical Relevance-Optical mapping has provided many insights into cardiac arrhythmias, but has traditionally been limited to ex-vivo preparations. The present findings extend the utility of optical mapping in the more realistic in-vivo setting and may eventually enable its use in patients.


Subject(s)
Fluorescent Dyes , Heart Arrest , Humans , Heart/diagnostic imaging
3.
Biophys J ; 122(21): 4207-4219, 2023 11 07.
Article in English | MEDLINE | ID: mdl-37775969

ABSTRACT

Optical mapping has been widely used in the study of cardiac electrophysiology in motion-arrested, ex vivo heart preparations. Recent developments in motion artifact mitigation techniques have made it possible to optically map beating ex vivo hearts, enabling the study of cardiac electromechanics using optical mapping. However, the ex vivo setting imposes limitations on optical mapping such as altered metabolic states, oversimplified mechanical loads, and the absence of neurohormonal regulation. In this study, we demonstrate optical electromechanical mapping in an in vivo heart preparation. Swine hearts were exposed via median sternotomy. Voltage-sensitive dye, either di-4-ANEQ(F)PTEA or di-5-ANEQ(F)PTEA, was injected into the left anterior descending artery. Fluorescence was excited by alternating green and amber light for excitation ratiometry. Cardiac motion during sinus and paced rhythm was tracked using a marker-based method. Motion tracking and excitation ratiometry successfully corrected most motion artifact in the membrane potential signal. Marker-based motion tracking also allowed simultaneous measurement of epicardial deformation. Reconstructed membrane potential and mechanical deformation measurements were validated using monophasic action potentials and sonomicrometry, respectively. Di-5-ANEQ(F)PTEA produced longer working time and higher signal/noise ratio than di-4-ANEQ(F)PTEA. In addition, we demonstrate potential applications of the new optical mapping system including electromechanical mapping during vagal nerve stimulation, fibrillation/defibrillation. and acute regional ischemia. In conclusion, although some technical limitations remain, optical mapping experiments that simultaneously image electrical and mechanical function can be conducted in beating, in vivo hearts.


Subject(s)
Heart , Swine , Animals , Heart/diagnostic imaging , Heart/physiology , Membrane Potentials , Action Potentials/physiology , Motion
SELECTION OF CITATIONS
SEARCH DETAIL