Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Tribol Lett ; 66(1): 4, 2018.
Article in English | MEDLINE | ID: mdl-31983860

ABSTRACT

Hydrogen diffusion during rolling contact fatigue (RCF) is considered a potential root cause or accelerator of white etching cracks (WECs) in wind turbine gearbox bearing steels. Hydrogen entry into the bearing steel during operation is thought to occur either through the contact surface itself or through cracks that breach the contact surface, in both cases by the decomposition of lubricant through catalytic reactions and/or tribochemical reactions of water. Thermal desorption analysis (TDA) using two experimental set-ups has been used to measure the hydrogen concentration in non-hydrogen-charged bearings over increasing RCF test durations for the first time. TDA on both instruments revealed that hydrogen diffused into the rolling elements, increasing concentrations being measured for longer test durations, with numerous WECs having formed. On the other hand, across all test durations, negligible concentrations of hydrogen were measured in the raceways, and correspondingly no WECs formed. Evidence for a relationship between hydrogen concentration and either the formation or the acceleration of WECs is shown in the rollers, as WECs increased in number and severity with increasing test duration. It is assumed that hydrogen diffusion occurred at wear-induced nascent surfaces or areas of heterogeneous/patchy tribofilm, since most WECs did not breach the contact surface, and those that did only had very small crack volumes for entry of lubricant to have occurred.

2.
Tribol Lett ; 66(1): 6, 2018.
Article in English | MEDLINE | ID: mdl-31983861

ABSTRACT

The formation of white etching cracks (WECs) in steel rolling element bearings can lead to the premature rolling contact fatigue (RCF) failure mode called white structure flaking. Driving mechanisms are still debated but are proposed to be combinations of mechanical, tribochemical and electrical effects. A number of studies have been conducted to record and map WECs in RCF-tested samples and bearings failed from the field. For the first time, this study uses serial sectioning metallography techniques on non-hydrogen charged test samples over a range of test durations to capture the evolution of WEC formation from their initiation to final flaking. Clear evidence for subsurface initiation at non-metallic inclusions was observed at the early stages of WEC formation, and with increasing test duration the propagation of these cracks from the subsurface region to the contact surface eventually causing flaking. In addition, an increase in the amount of associated microstructural changes adjacent to the cracks is observed, this being indicative of the crack being a prerequisite of the microstructural alteration.

3.
Bioinspir Biomim ; 7(3): 031001, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22535879

ABSTRACT

The performance of man-made materials can be improved by exploring new structures inspired by the architecture of biological materials. Natural materials, such as nacre (mother-of-pearl), can have outstanding mechanical properties due to their complicated architecture and hierarchical structure at the nano-, micro- and meso-levels which have evolved over millions of years. This review describes the numerous experimental methods explored to date to produce composites with structures and mechanical properties similar to those of natural nacre. The materials produced have sizes ranging from nanometres to centimetres, processing times varying from a few minutes to several months and a different range of mechanical properties that render them suitable for various applications. For the first time, these techniques have been divided into those producing bulk materials, coatings and free-standing films. This is due to the fact that the material's application strongly depends on its dimensions and different results have been reported by applying the same technique to produce materials with different sizes. The limitations and capabilities of these methodologies have been also described.


Subject(s)
Biomimetic Materials/chemical synthesis , Mollusca/chemistry , Nacre/chemical synthesis , Animals , Materials Testing
4.
Proc Inst Mech Eng H ; 225(11): 1061-9, 2011 Nov.
Article in English | MEDLINE | ID: mdl-22292204

ABSTRACT

Clearance is one of the most influential parameters on the tribological performance of metal-on-metal (MOM) hip joints and its selection is a subject of considerable debate. The objective of this paper is to study the lubrication behaviour of different clearances for MOM hip joints within the range of human physiological and pathological fluid viscosities. The frictional torques developed by MOM hip joints with a 50 mm diameter were measured for both virgin surfaces and during a wear simulator test. Joints were manufactured with three different diametral clearances: 20, 100, and 200 microm. The fluid used for the friction measurements which contained different ratios of 25 percent newborn calf serum and carboxymethyl cellulose (CMC) with the obtained viscosities values ranging from 0.001 to 0.71 Pa s. The obtained results indicate that the frictional torque for the 20 microm clearance joint remains high over the whole range of the viscosity values. The frictional torque of the 100 microm clearance joint was low for the very low viscosity (0.001 Pa s) lubricant, but increased with increasing viscosity value. The frictional torque of the 200 microm clearance joint was high at very low viscosity levels, however, it reduced with increasing viscosity. It is concluded that a smaller clearance level can enhance the formation of an elastohydrodynamic lubrication (EHL) film, but this is at the cost of preventing fluid recovery between the bearing surfaces during the unloaded phase of walking. Larger clearance bearings allow a better recovery of lubricant during the unloaded phase, which is necessary for higher viscosity lubricants. The selection of the clearance value should therefore consider both the formation of the EHL film and the fluid recovery as a function of the physiological viscosity in order to get an optimal tribological performance for MOM hip joints. The application of either 25 per cent bovine serum or water in existing in vitro tribological study should also be revised to consider the relevance of clinic synovial fluid viscosities and to avoid possible misleading results.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Joint/physiopathology , Animals , Cattle , Culture Media/metabolism , Friction , Gait , Hip Prosthesis , Humans , Lubricants/chemistry , Materials Testing , Metals/chemistry , Synovial Fluid/metabolism , Torque , Viscosity , Walking