Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
1.
Biol Cybern ; 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38922432

ABSTRACT

The coordination of complex behavior requires knowledge of both neural dynamics and the mechanics of the periphery. The feeding system of Aplysia californica is an excellent model for investigating questions in soft body systems' neuromechanics because of its experimental tractability. Prior work has attempted to elucidate the mechanical properties of the periphery by using a Hill-type muscle model to characterize the force generation capabilities of the key protractor muscle responsible for moving Aplysia's grasper anteriorly, the I2 muscle. However, the I1/I3 muscle, which is the main driver of retractions of Aplysia's grasper, has not been characterized. Because of the importance of the musculature's properties in generating functional behavior, understanding the properties of muscles like the I1/I3 complex may help to create more realistic simulations of the feeding behavior of Aplysia, which can aid in greater understanding of the neuromechanics of soft-bodied systems. To bridge this gap, in this work, the I1/I3 muscle complex was characterized using force-frequency, length-tension, and force-velocity experiments and showed that a Hill-type model can accurately predict its force-generation properties. Furthermore, the muscle's peak isometric force and stiffness were found to exceed those of the I2 muscle, and these results were analyzed in the context of prior studies on the I1/I3 complex's kinematics in vivo.

2.
Biol Cybern ; 2024 May 20.
Article in English | MEDLINE | ID: mdl-38769189

ABSTRACT

Studying the nervous system underlying animal motor control can shed light on how animals can adapt flexibly to a changing environment. We focus on the neural basis of feeding control in Aplysia californica. Using the Synthetic Nervous System framework, we developed a model of Aplysia feeding neural circuitry that balances neurophysiological plausibility and computational complexity. The circuitry includes neurons, synapses, and feedback pathways identified in existing literature. We organized the neurons into three layers and five subnetworks according to their functional roles. Simulation results demonstrate that the circuitry model can capture the intrinsic dynamics at neuronal and network levels. When combined with a simplified peripheral biomechanical model, it is sufficient to mediate three animal-like feeding behaviors (biting, swallowing, and rejection). The kinematic, dynamic, and neural responses of the model also share similar features with animal data. These results emphasize the functional roles of sensory feedback during feeding.

3.
Neuroinformatics ; 21(1): 163-176, 2023 01.
Article in English | MEDLINE | ID: mdl-36070028

ABSTRACT

Neuron morphology gives rise to distinct axons and dendrites and plays an essential role in neuronal functionality and circuit dynamics. In rat hippocampal neurons, morphological development occurs over roughly one week in vitro. This development has been qualitatively described as occurring in 5 stages. Still, there is a need to quantify cell growth to monitor cell culture health, understand cell responses to sensory cues, and compare experimental results and computational growth model predictions. To address this need, embryonic rat hippocampal neurons were observed in vitro over six days, and their processes were quantified using both standard morphometrics (degree, number of neurites, total length, and tortuosity) and new metrics (distance between change points, relative turning angle, and the number of change points) based on the Change-Point Test to track changes in path trajectories. Of the standard morphometrics, the total length of neurites per cell and the number of endpoints were significantly different between 0.5, 1.5, and 4 days in vitro, which are typically associated with Stages 2-4. Using the Change-Point Test, the number of change points and the average distance between change points per cell were also significantly different between those key time points. This work highlights key quantitative characteristics, both among common and novel morphometrics, that can describe neuron development in vitro and provides a foundation for analyzing directional changes in neurite growth for future studies.


Subject(s)
Neurites , Neurons , Rats , Animals , Neurites/physiology , Axons/physiology , Hippocampus , Cells, Cultured
4.
Bioinspir Biomim ; 18(1)2022 11 08.
Article in English | MEDLINE | ID: mdl-36265472

ABSTRACT

The past ten years have seen the rapid expansion of the field of biohybrid robotics. By combining engineered, synthetic components with living biological materials, new robotics solutions have been developed that harness the adaptability of living muscles, the sensitivity of living sensory cells, and even the computational abilities of living neurons. Biohybrid robotics has taken the popular and scientific media by storm with advances in the field, moving biohybrid robotics out of science fiction and into real science and engineering. So how did we get here, and where should the field of biohybrid robotics go next? In this perspective, we first provide the historical context of crucial subareas of biohybrid robotics by reviewing the past 10+ years of advances in microorganism-bots and sperm-bots, cyborgs, and tissue-based robots. We then present critical challenges facing the field and provide our perspectives on the vital future steps toward creating autonomous living machines.


Subject(s)
Robotics , Male , Humans , Semen , Muscles
5.
ACS Biomater Sci Eng ; 8(1): 303-313, 2022 01 10.
Article in English | MEDLINE | ID: mdl-34860495

ABSTRACT

Hydrogels are candidate building blocks in a wide range of biomaterial applications including soft and biohybrid robotics, microfluidics, and tissue engineering. Recent advances in embedded 3D printing have broadened the design space accessible with hydrogel additive manufacturing. Specifically, the Freeform Reversible Embedding of Suspended Hydrogels (FRESH) technique has enabled the fabrication of complex 3D structures using extremely soft hydrogels, e.g., alginate and collagen, by assembling hydrogels within a fugitive support bath. However, the low structural rigidity of FRESH printed hydrogels limits their applications, especially those that require operation in nonaqueous environments. In this study, we demonstrated long-fiber embedded hydrogel 3D printing using a multihead printing platform consisting of a custom-built fiber extruder and an open-source FRESH bioprinter with high embedding fidelity. Using this process, fibers were embedded in 3D printed hydrogel components to achieve significant structural reinforcement (e.g., tensile modulus improved from 56.78 ± 8.76 to 382.55 ± 25.29 kPa and tensile strength improved from 9.44 ± 2.28 to 45.05 ± 5.53 kPa). In addition, we demonstrated the versatility of this technique by using fibers of a wide range of sizes and material types and implementing different 2D and 3D embedding patterns, such as embedding a conical helix using electrochemically aligned collagen fiber via nonplanar printing. Moreover, the technique was implemented using low-cost material and is compatible with open-source software and hardware, which facilitates its adoption and modification for new research applications.


Subject(s)
Hydrogels , Printing, Three-Dimensional , Alginates , Biocompatible Materials , Tissue Engineering
6.
Front Oncol ; 11: 743256, 2021.
Article in English | MEDLINE | ID: mdl-34660306

ABSTRACT

OBJECTIVE: The overall objective of this clinical study was to validate an implantable oxygen sensor, called the 'OxyChip', as a clinically feasible technology that would allow individualized tumor-oxygen assessments in cancer patients prior to and during hypoxia-modification interventions such as hyperoxygen breathing. METHODS: Patients with any solid tumor at ≤3-cm depth from the skin-surface scheduled to undergo surgical resection (with or without neoadjuvant therapy) were considered eligible for the study. The OxyChip was implanted in the tumor and subsequently removed during standard-of-care surgery. Partial pressure of oxygen (pO2) at the implant location was assessed using electron paramagnetic resonance (EPR) oximetry. RESULTS: Twenty-three cancer patients underwent OxyChip implantation in their tumors. Six patients received neoadjuvant therapy while the OxyChip was implanted. Median implant duration was 30 days (range 4-128 days). Forty-five successful oxygen measurements were made in 15 patients. Baseline pO2 values were variable with overall median 15.7 mmHg (range 0.6-73.1 mmHg); 33% of the values were below 10 mmHg. After hyperoxygenation, the overall median pO2 was 31.8 mmHg (range 1.5-144.6 mmHg). In 83% of the measurements, there was a statistically significant (p ≤ 0.05) response to hyperoxygenation. CONCLUSIONS: Measurement of baseline pO2 and response to hyperoxygenation using EPR oximetry with the OxyChip is clinically feasible in a variety of tumor types. Tumor oxygen at baseline differed significantly among patients. Although most tumors responded to a hyperoxygenation intervention, some were non-responders. These data demonstrated the need for individualized assessment of tumor oxygenation in the context of planned hyperoxygenation interventions to optimize clinical outcomes.

8.
Clin Orthop Relat Res ; 479(2): 406-418, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33165033

ABSTRACT

BACKGROUND: Fatty infiltration of the rotator cuff occurs after injury to the tendon and results in a buildup of adipose in the muscle. Fatty infiltration may be a biomarker for predicting future injuries and mechanical properties after tendon repair. As such, quantifying fatty infiltration accurately could be a relevant metric for determining the success of tendon repairs. Currently, fatty infiltration is quantified by an experienced observer using the Goutallier or Fuchs staging system, but because such score-based quantification systems rely on subjective assessments, newer techniques using semiautomated analyses in CT and MRI were developed and have met with varying degrees of success. However, semiautomated analyses of CT and MRI results remain limited in cases where only a few two-dimensional slices of tissue are examined and applied to the three-dimensional (3-D) tissue structure. We propose that it is feasible to assess fatty infiltration within the 3-D volume of muscle and tendon in a semiautomated fashion by selecting anatomic features and examining descriptive metrics of intensity histograms collected from a cylinder placed within the central volume of the muscle and tendon of interest. QUESTIONS/PURPOSES: (1) Do descriptive metrics (mean and SD) of intensity histograms from microCT images correlate with the percentage of fat present in muscle after rotator cuff repair? (2) Do descriptive metrics of intensity histograms correlate with the maximum load during mechanical testing of rotator cuff repairs? METHODS: We developed a custom semiautomated program to generate intensity histograms based on user-selected anatomic features. MicroCT images were obtained from 12 adult female New Zealand White rabbits (age 8 to 12 months, weight 3.7 kg ± 5 kg) that were randomized to surgical repair or sham repair of an induced infraspinatus defect. Intensity histograms were generated from images of the operative and contralateral intact shoulder in these rabbits which were presented to the user in a random order without identifying information to minimize sources of bias. The mean and SD of the intensity histograms were calculated and compared with the total percentage of the volume threshold as fat. Patterns of fat identified were qualitatively compared with histologic samples to confirm that thresholding was detecting fat. We conducted monotonic tensile strength-to-failure tests of the humeral-infraspinatus bone-tendon-muscle complex, and evaluated associations between histogram mean and SDs and maximum load. RESULTS: The total percentage of fat was negatively correlated with the intensity histogram mean (Pearson correlation coefficient -0.92; p < 0.001) and positively with intensity histogram SD (Pearson correlation coefficient 0.88; p < 0.001), suggesting that the increase in fat leads to a reduction and wider variability in volumetric tissue density. The percentage of fat content was also negatively correlated with the maximum load during mechanical testing (Pearson correlation coefficient -78; p = 0.001), indicating that as the percentage of fat in the volume increases, the mechanical strength of the repair decreases. Furthermore, the intensity histogram mean was positively correlated with maximum load (Pearson correlation coefficient 0.77; p = 0.001) and histogram SD was negatively correlated with maximum load (Pearson correlation coefficient -0.72; p = 0.004). These correlations were strengthened by normalizing maximum load to account for animal size (Pearson correlation coefficient 0.86 and -0.9, respectively), indicating that as histogram mean decreases, the maximum load of the repair decreases and as histogram spread increases, the maximum load decreases. CONCLUSION: In this ex vivo rabbit model, a semiautomated approach to quantifying fat on microCT images was a noninvasive way of quantifying fatty infiltration associated with the strength of tendon healing. CLINICAL RELEVANCE: Histogram-derived variables may be useful as surrogate measures of repair strength after rotator cuff repair. The preclinical results presented here provide a foundation for future studies to translate this technique to patient studies and additional imaging modalities. This semiautomated method provides an accessible approach to quantification of fatty infiltration by users of varying experience and can be easily adapted to any intensity-based imaging approach. To translate this approach to clinical practice, this technique should be calibrated for MRI or conventional CT imaging and applied to patient scans. Further investigations are needed to assess the correlation of volumetric intensity histogram descriptive metrics to clinical mechanical outcomes.


Subject(s)
Adipose Tissue/diagnostic imaging , Adipose Tissue/pathology , Rotator Cuff Injuries/diagnostic imaging , Rotator Cuff Injuries/surgery , X-Ray Microtomography , Animals , Female , Imaging, Three-Dimensional , Rabbits
9.
Biol Cybern ; 114(6): 557-588, 2020 12.
Article in English | MEDLINE | ID: mdl-33301053

ABSTRACT

Animals exhibit remarkable feats of behavioral flexibility and multifunctional control that remain challenging for robotic systems. The neural and morphological basis of multifunctionality in animals can provide a source of bioinspiration for robotic controllers. However, many existing approaches to modeling biological neural networks rely on computationally expensive models and tend to focus solely on the nervous system, often neglecting the biomechanics of the periphery. As a consequence, while these models are excellent tools for neuroscience, they fail to predict functional behavior in real time, which is a critical capability for robotic control. To meet the need for real-time multifunctional control, we have developed a hybrid Boolean model framework capable of modeling neural bursting activity and simple biomechanics at speeds faster than real time. Using this approach, we present a multifunctional model of Aplysia californica feeding that qualitatively reproduces three key feeding behaviors (biting, swallowing, and rejection), demonstrates behavioral switching in response to external sensory cues, and incorporates both known neural connectivity and a simple bioinspired mechanical model of the feeding apparatus. We demonstrate that the model can be used for formulating testable hypotheses and discuss the implications of this approach for robotic control and neuroscience.


Subject(s)
Aplysia , Deglutition , Animals , Biomechanical Phenomena , Feeding Behavior
10.
Adv Exp Med Biol ; 1072: 233-239, 2018.
Article in English | MEDLINE | ID: mdl-30178351

ABSTRACT

This paper considers the critical role that academics can have in the development of clinical innovations and especially how their impact can be optimized. The focus should be on establishing the safety and efficacy of new approaches while also incorporating human factors and human use considerations into the inventions. It is very advantageous to work in concert with the end-users (operators and clinicians) to help ensure that the innovation will be useful and feasible to be incorporated into actual clinical practice as intended. This strategy enables developments to tackle real clinical needs by providing novel strategies to improve patient care while using solutions that fit into clinical practice and that are welcomed by patients and clinical staff. These principles are illustrated by a case study of the development of clinical in vivo EPR oximetry.


Subject(s)
Equipment Design , Inventions , Oximetry/methods , Biomedical Engineering , Biomedical Technology , Humans
11.
Health Phys ; 115(1): 140-150, 2018 07.
Article in English | MEDLINE | ID: mdl-29787440

ABSTRACT

Instrumentation and application methodologies for rapidly and accurately estimating individual ionizing radiation dose are needed for on-site triage in a radiological/nuclear event. One such methodology is an in vivo X-band, electron paramagnetic resonance, physically based dosimetry method to directly measure the radiation-induced signal in fingernails. The primary components under development are key instrument features, such as resonators with unique geometries that allow for large sampling volumes but limit radiation-induced signal measurements to the nail plate, and methodological approaches for addressing interfering signals in the nail and for calibrating dose from radiation-induced signal measurements. One resonator development highlighted here is a surface resonator array designed to reduce signal detection losses due to the soft tissues underlying the nail plate. Several surface resonator array geometries, along with ergonomic features to stabilize fingernail placement, have been tested in tissue-equivalent nail models and in vivo nail measurements of healthy volunteers using simulated radiation-induced signals in their fingernails. These studies demonstrated radiation-induced signal detection sensitivities and quantitation limits approaching the clinically relevant range of ≤ 10 Gy. Studies of the capabilities of the current instrument suggest that a reduction in the variability in radiation-induced signal measurements can be obtained with refinements to the surface resonator array and ergonomic features of the human interface to the instrument. Additional studies are required before the quantitative limits of the assay can be determined for triage decisions in a field application of dosimetry. These include expanded in vivo nail studies and associated ex vivo nail studies to provide informed approaches to accommodate for a potential interfering native signal in the nails when calculating the radiation-induced signal from the nail plate spectral measurements and to provide a method for calibrating dose estimates from the radiation-induced signal measurements based on quantifying experiments in patients undergoing total-body irradiation or total-skin electron therapy.


Subject(s)
Biological Assay/methods , Electron Spin Resonance Spectroscopy/methods , Mechanotransduction, Cellular/radiation effects , Nails/chemistry , Radiometry/methods , Triage/standards , Humans , Nails/radiation effects , Radiation Dosage
12.
J Biomech Eng ; 140(2)2018 02 01.
Article in English | MEDLINE | ID: mdl-28901373

ABSTRACT

Motor proteins play critical roles in the normal function of cells and proper development of organisms. Among motor proteins, failings in the normal function of two types of proteins, kinesin and dynein, have been shown to lead many pathologies, including neurodegenerative diseases and cancers. As such, it is critical to researchers to understand the underlying mechanics and behaviors of these proteins, not only to shed light on how failures may lead to disease, but also to guide research toward novel treatment and nano-engineering solutions. To this end, many experimental techniques have been developed to measure the force and motility capabilities of these proteins. This review will (a) discuss such techniques, specifically microscopy, atomic force microscopy (AFM), optical trapping, and magnetic tweezers, and (b) the resulting nanomechanical properties of motor protein functions such as stalling force, velocity, and dependence on adenosine triphosophate (ATP) concentrations will be comparatively discussed. Additionally, this review will highlight the clinical importance of these proteins. Furthermore, as the understanding of the structure and function of motor proteins improves, novel applications are emerging in the field. Specifically, researchers have begun to modify the structure of existing proteins, thereby engineering novel elements to alter and improve native motor protein function, or even allow the motor proteins to perform entirely new tasks as parts of nanomachines. Kinesin and dynein are vital elements for the proper function of cells. While many exciting experiments have shed light on their function, mechanics, and applications, additional research is needed to completely understand their behavior.


Subject(s)
Dyneins/metabolism , Kinesins/metabolism , Mechanical Phenomena , Adenosine Triphosphate/metabolism , Dyneins/chemistry , Dyneins/genetics , Humans , Kinesins/chemistry , Kinesins/genetics , Protein Engineering
13.
Adv Exp Med Biol ; 977: 297-312, 2017.
Article in English | MEDLINE | ID: mdl-28685459

ABSTRACT

Clinical EPR spectroscopy is emerging as an important modality, with the potential to be used in standard clinical practice to determine the extent of hypoxia in tissues and whether hypoxic tissues respond to breathing enriched oxygen during therapy. Oximetry can provide important information useful for prognosis and to improve patient outcomes. EPR oximetry has many potential advantages over other ways to measure oxygen in tissues, including directly measuring oxygen in tissues and being particularly sensitive to low oxygen, repeatable, and non-invasive after an initial injection of the EPR-sensing material is placed in the tumor. The most immediately available oxygen sensor is India ink, where two classes of carbon (carbon black and charcoal) have been identified as having acceptable paramagnetic properties for oximetry. While India ink has a long history of safe use in tattoos, a systematic research search regarding its safety for marking tissues for medical uses and an examination of the evidence that differentiates between ink based on charcoal or carbon black has not been conducted. METHODS: Using systematic literature search techniques, we searched the PubMed and Food and Drug Administration databases, finding ~1000 publications reporting on adverse events associated with India/carbon based inks. The detailed review of outcomes was based on studies involving >16 patients, where the ink was identifiable as carbon black or charcoal. RESULTS: Fifty-six studies met these criteria. There were few reports of complications other than transient and usually mild discomfort and bleeding at injection, and there was no difference in charcoal vs. carbon black India ink. CONCLUSIONS: India ink was generally well tolerated by patients and physicians reported that it was easy to use in practice and used few resources. The risk is low enough to justify its use as an oxygen sensor in clinical practice.


Subject(s)
Biosensing Techniques/methods , Carbon , Electron Spin Resonance Spectroscopy , Oximetry/methods , Animals , Biosensing Techniques/instrumentation , Carbon/adverse effects , Carbon/analysis , Coloring Agents/adverse effects , Coloring Agents/analysis , Electron Spin Resonance Spectroscopy/adverse effects , Electron Spin Resonance Spectroscopy/instrumentation , Electron Spin Resonance Spectroscopy/methods , Humans , Oximetry/adverse effects
14.
Sci Robot ; 2(12)2017 11 22.
Article in English | MEDLINE | ID: mdl-31360812

ABSTRACT

Can we create robots with the behavioral flexibility and robustness of animals? Engineers often use bio-inspiration to mimic animals. Recent advances in tissue engineering now allow the use of components from animals. By integrating organic and synthetic components, researchers are moving towards the development of engineered organisms whose structural framework, actuation, sensing, and control are partially or completely organic. This review discusses recent exciting work demonstrating how organic components can be used for all facets of robot development. Based on this analysis, we propose a Robotic Taxonomic Key to guide the field towards a unified lexicon for device description.

15.
Radiat Prot Dosimetry ; 172(1-3): 72-80, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27421468

ABSTRACT

Several important recent advances in the development and evolution of in vivo Tooth Biodosimetry using Electron Paramagnetic Resonance (EPR) allow its performance to meet or exceed the U.S. targeted requirements for accuracy and ease of operation and throughput in a large-scale radiation event. Ergonomically based changes to the magnet, coupled with the development of rotation of the magnet and advanced software to automate collection of data, have made it easier and faster to make a measurement. From start to finish, measurements require a total elapsed time of 5 min, with data acquisition taking place in less than 3 min. At the same time, the accuracy of the data for triage of large populations has improved, as indicated using the metrics of sensitivity, specificity and area under the ROC curve. Applying these standards to the intended population, EPR in vivo Tooth Biodosimetry has approximately the same diagnostic accuracy as the purported 'gold standard' (dicentric chromosome assay). Other improvements include miniaturisation of the spectrometer, leading to the creation of a significantly lighter and more compact prototype that is suitable for transporting for Point of Care (POC) operation and that can be operated off a single standard power outlet. Additional advancements in the resonator, including use of a disposable sensing loop attached to the incisor tooth, have resulted in a biodosimetry method where measurements can be made quickly with a simple 5-step workflow and by people needing only a few minutes of training (which can be built into the instrument as a training video). In sum, recent advancements allow this prototype to meet or exceed the US Federal Government's recommended targets for POC biodosimetry in large-scale events.


Subject(s)
Biological Assay/methods , Electron Spin Resonance Spectroscopy/methods , Radiation Exposure/analysis , Radiation Monitoring/methods , Tooth/chemistry , Tooth/radiation effects , Triage/methods , Biomarkers/analysis , Humans , Radiation Dosage , Radioactive Hazard Release , Reproducibility of Results , Sensitivity and Specificity , Technology Assessment, Biomedical
16.
Radiat Prot Dosimetry ; 172(1-3): 87-95, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27421470

ABSTRACT

Managing radiation injuries following a catastrophic event where large numbers of people may have been exposed to life-threatening doses of ionizing radiation relies on the availability of biodosimetry to assess whether individuals need to be triaged for care. Electron Paramagnetic Resonance (EPR) tooth dosimetry is a viable method to accurately estimate the amount of ionizing radiation to which an individual has been exposed. In the intended measurement conditions and scenario, it is essential that the measurement process be fast, straightforward and provides meaningful and accurate dose estimations for individuals in the expected measurement conditions. The sensing component of a conventional L-band EPR spectrometer used for tooth dosimetry typically consists of a surface coil resonator that is rigidly, physically attached to the coupler. This design can result in cumbersome operation, limitations in teeth geometries that may be measured and hinder the overall utility of the dosimeter. A novel surface coil resonator has been developed for the currently existing L-band (1.15 GHz) EPR tooth dosimeter for the intended use as a point of care device by minimally trained operators. This resonator development provides further utility to the dosimeter, and increases the usability of the dosimeter by non-expert operators in the intended use scenario.


Subject(s)
Biological Assay/instrumentation , Radiometry/instrumentation , Tooth/chemistry , Tooth/radiation effects , Transducers , Wireless Technology/instrumentation , Elastic Modulus , Equipment Design , Equipment Failure Analysis , Humans , Magnetics/instrumentation , Miniaturization , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...