Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
2.
J Atr Fibrillation ; 8(6): 1396, 2016.
Article in English | MEDLINE | ID: mdl-27909501

ABSTRACT

In patients known to be a high risk for sudden cardiac arrest, implantable cardioverter defibrillators (ICD) are a proven therapy to reduce risk of death. However, in patients without conventional indications for pacing, the optimal strategy for type of device, dual- versus single-chamber, remains debatable. The benefit of prophylactic pacing in this category of patients has never been documented. Although available atrial electrograms in a dual chamber system improve interpretation of stored arrhythmia events, allow monitoring of atrial fibrillation and may potentially reduce the risk of inappropriate shocks by enhancing automated arrhythmia discrimination, the use of dual-chamber ICDs has a number of disadvantages. The addition of an atrial lead adds complexity to implantation and extraction procedures, increases procedural cost and is associated with a higher risk of periprocedural complications. The single lead pacing system with ability to sense atrial signals via floating atrial electrodes (VDD) clinically became available in early 1980's but did not gain much popularity due to inconsistent atrial sensing and concerns about the potential need for an atrial lead if sinus node fails. Most ICD patients do not have indications for pacing at implantation and subsequent risk of symptomatic bradycardia seems to be low. The concept of atrial sensing via floating electrodes has recently been revitalized in the Biotronik DX ICD system (Biotronik, SE & Co., Berlin, Germany) aiming to provide all of the potential advantages of available atrial electrograms without the risks and incremental cost of an additional atrial lead. Compared to a traditional VDD pacing system, the DX ICD system uses an optimized (15 mm) atrial dipole spacing and improved atrial signal processing to offer more reliable atrial sensing. The initial experience with the DX system indicates that the clinically useful atrial signal amplitude in sinus rhythm remains stable over time. Future studies are needed to determine reliability of atrial sensing during tachyarrhythmias, particularly atrial fibrillation as well as clinical utility and cost-effectiveness of this technology in different populations of patients.

3.
Pacing Clin Electrophysiol ; 39(12): 1327-1334, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27778352

ABSTRACT

BACKGROUND: Available atrial electrograms in implantable cardioverter defibrillators (ICDs) improve arrhythmia diagnosis, allow monitoring for atrial fibrillation, and may reduce the risk of inappropriate therapies. A recently introduced ICD system using a single-lead with floating atrial electrodes provides diagnostic capability of a dual-chamber system without placing an additional lead. Data on long-term clinical performance of this system are limited. METHODS: We retrospectively analyzed data from 35 consecutive patients implanted with Biotronik VR-T DX devices and LinoxSmart DX leads. (Biotronik, SE & Co., Berlin, Germany) RESULTS: Of 35 patients (77% male, age 52 ± 11.28 years), 32 were followed for a mean of 432 ± 197 days (range 56-765). During implantation, average preamplified and amplified sinus P-wave amplitudes were 2.61 ± 1.39 mV (range 0.9-6.8 mV) and 8.7 ± 4.51 mV (range 1.4-18 mV), respectively. Despite statistically significant variations, the amplified P-wave amplitude measurements (calculated mean values over 3 months) remained within a clinically acceptable range during follow-up (5.4-8.7 mV). R-wave amplitude and ventricular pacing threshold measurements were stable over time. A total of 13 stored arrhythmia events (three ventricular tachycardia, eight supraventricular tachycardia, two atrial fibrillation) were reviewed. All of them showed readily interpretable atrial electrograms. Eight out of 10 (80%) supraventricular events were correctly classified by the device. Three patients received inappropriate ICD therapies. CONCLUSION: The single-lead ICD system using a floating atrial dipole provides reliable recording of atrial signals during sinus rhythm and arrhythmias. Our data suggest that the system may offer diagnostic advantages of a dual-chamber device without potential risks of an additional atrial lead.


Subject(s)
Amplifiers, Electronic , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/prevention & control , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electrodes, Implanted , Electrophysiologic Techniques, Cardiac/instrumentation , Equipment Design , Equipment Failure Analysis , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
4.
J Nucl Cardiol ; 22(1): 115-22, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24980454

ABSTRACT

BACKGROUND: Correction for soft tissue signal attenuation can improve the diagnostic accuracy of single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI). The aim of this study was to correlate SPECT-MPI findings with clinical outcomes in patients who underwent stress imaging in the supine position, who also underwent "second look" stress imaging in the prone position. METHODS: Patients without perfusion abnormalities were considered Normal (N = 270). Those with apparent supine stress perfusion abnormalities which all resolved during prone imaging formed the Normal-Prone group (N = 309). Patients with matched perfusion abnormalities during both supine and prone stress imaging were considered Abnormal (N = 169). RESULTS: During follow-up (187 ± 96 days), utilization rates for invasive coronary angiography were similar for Normal vs Normal-Prone patients (3.5% vs 3.8%; P = NS), but were significantly higher in Abnormal patients (42.4%, P < .0001). Coronary revascularization occurred in 0.78%, 0.64%, and 17.7% of Normal, Normal-Prone, and Abnormal patients, respectively (P < .001). Cardiac death or myocardial infarction occurred in 2.2%, 2.3%, and 6.3% of Normal, Normal-Prone, and Abnormal patients, respectively (P = .02). CONCLUSIONS: Second look SPECT-MPI identifies patients at low risk for death or myocardial infarction, who infrequently require invasive coronary angiography.


Subject(s)
Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Myocardial Infarction/diagnostic imaging , Myocardial Perfusion Imaging , Tomography, Emission-Computed, Single-Photon , Aged , Coronary Artery Disease/diagnosis , Death , Exercise Test , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Myocardial Infarction/diagnosis , Patient Positioning , Prognosis , Radiopharmaceuticals , Retrospective Studies , Treatment Outcome
5.
J Occup Environ Med ; 53(9): 1046-53, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21866051

ABSTRACT

OBJECTIVE: To estimate prevalence and risk factors for International Labour Organization radiographic abnormalities, and assess relationship of these abnormalities with spirometry results in former Department of Energy nuclear weapons workers. METHODS: Participants were offered chest x-ray (CXR) and lung function testing. Three occupational medicine physicians read CXRs. RESULTS: Forty-five (5.9%) of 757 screened workers were found to have isolated parenchymal abnormalities on CXR and this rate is higher than that in many Department of Energy studies. Parenchymal and pleural and isolated pleural abnormalities were found in 19 (2.5%) and 37 (4.9%) workers, respectively, and these rates are lower than those in other Department of Energy studies to date. Lung function impairment was associated with radiographic abnormalities. CONCLUSIONS: This study found an elevated rate of parenchymal abnormalities compared to other DoE populations but the effect of age or other causes could not be ruled out.


Subject(s)
Lung Diseases/epidemiology , Lung/diagnostic imaging , Nuclear Weapons , Occupational Diseases/epidemiology , Pleura/diagnostic imaging , Pleural Diseases/epidemiology , Aged , Aged, 80 and over , Asbestos/adverse effects , Barium/adverse effects , Beryllium/adverse effects , Beryllium/immunology , Explosive Agents/adverse effects , Female , Humans , Logistic Models , Lung/physiopathology , Lung Diseases/diagnostic imaging , Lung Diseases/physiopathology , Male , Middle Aged , Occupational Diseases/diagnostic imaging , Occupational Diseases/physiopathology , Occupational Exposure/adverse effects , Pleura/physiopathology , Pleural Diseases/diagnostic imaging , Pleural Diseases/physiopathology , Prevalence , Radiography , Spirometry , Statistics, Nonparametric , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...