1.
Ann Biomed Eng ; 49(12): 3176-3188, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34580782

ABSTRACT

Despite the potential for biomechanical conditioning with prosthetic use, the soft tissues of residual limbs following lower-limb amputation are vulnerable to damage. Imaging studies revealing morphological changes in these soft tissues have not distinguished between superficial and intramuscular adipose distribution, despite the recognition that intramuscular fat levels indicate reduced tolerance to mechanical loading. Furthermore, it is unclear how these changes may alter tissue tone and stiffness, which are key features in prosthetic socket design. This study was designed to compare the morphology and biomechanical response of limb tissues to mechanical loading in individuals with and without transtibial amputation, using magnetic resonance imaging in combination with tissue structural stiffness. The results revealed higher adipose infiltrating muscle in residual limbs than in intact limbs (residual: median 2.5% (range 0.2-8.9%); contralateral: 1.7% (0.1-5.1%); control: 0.9% (0.4-1.3%)), indicating muscle atrophy and adaptation post-amputation. The intramuscular adipose content correlated negatively with daily socket use, although there was no association with time post-amputation. Residual limbs were significantly stiffer than intact limbs at the patellar tendon site, which plays a key role in load transfer across the limb-prosthesis interface. The tissue changes following amputation have relevance in the clinical understanding of prosthetic socket design variables and soft tissue damage risk in this vulnerable group.


Subject(s)
Adaptation, Physiological , Amputation Stumps , Tibia/surgery , Artificial Limbs , Biomechanical Phenomena , Humans , Pressure , Skin/injuries , Soft Tissue Injuries/physiopathology , Stress, Mechanical
2.
J Tissue Viability ; 30(3): 395-401, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34030943

ABSTRACT

Temperature and humidity conditions at the interface between a support surface and the skin, termed microclimate, has been implicated in the development of pressure ulcers. Support surface technologies have been developed to control microclimate conditions, although only a few standard test methods exist to evaluate their performance. This study describes a combined experimental-computational approach to analyzing microclimate control systems. The study used a modified physical model protocol to evaluate two specific support surface systems involving a spacer fabric cover with i) no air flow and ii) an active fan. The physical model deposited moisture at a controlled rate for 25 min, and the microclimate conditions under the model and the surrounding area were monitored for 24 h. Using the experimental data as boundary conditions, a finite element model was developed using mass transport principles, which was calibrated using experimental results. Model inputs included mass density and mass diffusivity, resulting in an estimated absolute humidity change over time. The physical model tests revealed distinct differences between the support surfaces with and without active airflow, with the former having little effect on local humidity levels (RH>75% for 24hr). By contrast, there was a spatial and temporal change in microclimate with the active fan, with sensors positioned towards the source of airflow reaching ambient conditions within 24hr. The computational model was refined to produce comparable results with respect to both the spatial distribution of microclimate and the change in values over time. The combined experimental and computation approach was able to distinguish distinct difference in microclimate change between two support surface designs. The approach could enable the efficient evaluation of different mattress design principles to aid decision making for personalized support surface solutions, for the prevention of pressure ulcers.


Subject(s)
Computer Simulation , Microclimate , Models, Theoretical , Humans , Humidity/adverse effects , Pressure Ulcer/prevention & control , Program Development/methods , Skin Physiological Phenomena , Temperature
3.
Article in English | MEDLINE | ID: mdl-33241703

ABSTRACT

Respiratory masks are used to deliver non-invasive ventilation for cardiorespiratory pathologies. Masks must minimize skin tissue compression while maintaining a seal at the interface. Ill-fitting masks or those applied too tightly are implicated in pressure ulcer formation. This study aimed to analyse respiratory mask goodness of fit in a cohort of face shapes. A number of parameters were identified and analysed with a novel registration protocol. In the majority of cases, mask indentation exceeded the thickness of the interface material and significant gapping was observed. The size range was most appropriate for males, with only one size suitable for females.

4.
J Tissue Viability ; 29(4): 277-283, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32943281

ABSTRACT

BACKGROUND: Diabetes-Related Foot Ulcers (DRFUs) are a common and devastating consequence of Diabetes Mellitus and are associated with high morbidity, mortality, social and economic costs. Whilst peak plantar pressures during gait are implicated cited as a major contributory factor, DRFU occurrence has also been associated with increased periods of sedentary behaviour. The present study was designed aimed to assess the effects of sitting postures on plantar tissue health. METHODS: After a period of acclimatisation, transcutaneous oxygen tensions (TCPO2) and inflammatory cytokines (IL-1α and IL-1RA) were measured at the dorsal and plantar aspects of the forefoot before, during and after a 20-min period of seated-weight-bearing in participants with diabetes (n = 11) and no diabetes (n = 10). Corresponding interface pressures at the plantar site were also measured. RESULTS: During weight-bearing, participants with diabetes showed increases in tissue ischaemia which were linearly correlated proportional to plantar pressures (Pearson's r = 0.81; p < 0.05). Within the healthy group, no such correlation was evident (p > 0.05). There were also significant increases in post seated weight-bearing values for ratio for IL-1α and IL-1RA, normalised to total protein, post seated weight-bearing in participants with diabetes compared to healthy controls. CONCLUSION: This study shows that prolonged sitting may be detrimental to plantar skin health. It highlights the need to further examine the effects of prolonged sitting in individuals, who may have a reduced tolerance to loading in the plantar skin and soft tissues.


Subject(s)
Diabetes Complications/physiopathology , Diabetic Foot/diagnosis , Sedentary Behavior , Skin/physiopathology , Adult , Body Mass Index , Diabetes Mellitus/physiopathology , Diabetic Foot/classification , Female , Healthy Volunteers/statistics & numerical data , Humans , Interleukin 1 Receptor Antagonist Protein/analysis , Interleukin 1 Receptor Antagonist Protein/blood , Interleukin-1alpha/analysis , Interleukin-1alpha/blood , Male , Middle Aged , Pressure/adverse effects
5.
Med Eng Phys ; 78: 39-47, 2020 04.
Article in English | MEDLINE | ID: mdl-32035813

ABSTRACT

BACKGROUND: In the early stages of rehabilitation after primary amputation, residual limb soft tissues have not been mechanically conditioned to support load and are vulnerable to damage from prosthetic use. There is limited quantitative knowledge of skin and soft tissue response to prosthetic loading. METHODS: An in-vivo protocol was developed to establish suitable measures to assess tissue tolerance during loading representative of early prosthesis use. Ten participants without amputation one participant with trans-tibial amputation were recruited, and pressure applied to their calf in increments from 20 to 60 mmHg. Measurements were recorded at relevant skin sites including interface pressures, transcutaneous oxygen (TCPO2) and carbon dioxide (TCPCO2) tensions and inflammatory biomarkers. FINDINGS: At the maximum cuff pressure, mean interface pressures were between 66 and 74 mmHg, associated with decreased TCPO2 values. On the release of pressure, the ischaemic response was reversed. Significant upregulation (p < 0.05) in inflammatory biomarker IL-1α and its antagonist IL-1RA were observed at all sites immediately following loading. INTERPRETATION: The protocol was successful in applying representative prosthetic loads to lower limb tissues and monitoring the physiological response, both in terms of tissue ischemia and skin inflammation. Results indicated that the measurement approaches were sensitive to changes in interface conditions, offering a promising approach to monitor tissue status for people with amputation.


Subject(s)
Mechanical Tests/instrumentation , Prostheses and Implants , Adult , Biomarkers/metabolism , Biomechanical Phenomena , Carbon Dioxide/metabolism , Cohort Studies , Female , Humans , Male , Oxygen/metabolism , Pressure , Skin/metabolism , Weight-Bearing , Young Adult
6.
Biomech Model Mechanobiol ; 19(4): 1331-1346, 2020 Aug.
Article in English | MEDLINE | ID: mdl-31256276

ABSTRACT

It has been proposed that finite element analysis can complement clinical decision making for the appropriate design and manufacture of prosthetic sockets for amputees. However, clinical translation has not been achieved, in part due to lengthy solver times and the complexity involved in model development. In this study, a parametric model was created, informed by variation in (i) population-driven residuum shape morphology, (ii) soft tissue compliance and (iii) prosthetic socket design. A Kriging surrogate model was fitted to the response of the analyses across the design space enabling prediction for new residual limb morphologies and socket designs. It was predicted that morphological variability and prosthetic socket design had a substantial effect on socket-limb interfacial pressure and shear conditions as well as sub-dermal soft tissue strains. These relationships were investigated with a higher resolution of anatomical, surgical and design variability than previously reported, with a reduction in computational expense of six orders of magnitude. This enabled real-time predictions (1.6 ms) with error vs the analytical solutions of < 4 kPa in pressure at residuum tip, and < 3% in soft tissue strain. As such, this framework represents a substantial step towards implementation of finite element analysis in the prosthetics clinic.


Subject(s)
Artificial Limbs , Models, Biological , Prosthesis Design , Tibia/surgery , Biomechanical Phenomena , Finite Element Analysis , Humans , Pressure , Principal Component Analysis , Regression Analysis
7.
Biomech Model Mechanobiol ; 19(4): 1347-1360, 2020 Aug.
Article in English | MEDLINE | ID: mdl-31741116

ABSTRACT

In post-amputation rehabilitation, a common goal is to return to ambulation using a prosthetic limb, suspended by a customised socket. Prosthetic socket design aims to optimise load transfer between the residual limb and mechanical limb, by customisation to the user. This is a time-consuming process, and with the increase in people requiring these prosthetics, it is vital that these personalised devices can be produced rapidly while maintaining excellent fit, to maximise function and comfort. Prosthetic sockets are designed by capturing the residual limb's shape and applying a series of geometrical modifications, called rectifications. Expert knowledge is required to achieve a comfortable fit in this iterative process. A variety of rectifications can be made, grouped into established strategies [e.g. in transtibial sockets: patellar tendon bearing (PTB) and total surface bearing (TSB)], creating a complex design space. To date, adoption of advanced engineering solutions to support fitting has been limited. One method is numerical optimisation, which allows the designer a number of likely candidate solutions to start the design process. Numerical optimisation is commonly used in many industries but not prevalent in the design of prosthetic sockets. This paper therefore presents candidate shape optimisation methods which might benefit the prosthetist and the limb user, by blending the state of the art from prosthetic mechanical design, surrogate modelling and evolutionary computation. The result of the analysis is a series of prosthetic socket designs that preferentially load and unload the pressure tolerant and intolerant regions of the residual limb. This spectrum is bounded by the general forms of the PTB and TSB designs, with a series of variations in between that represent a compromise between these accepted approaches. This results in a difference in pressure of up to 31 kPa over the fibula head and 14 kPa over the residuum tip. The presented methods would allow a trained prosthetist to rapidly assess these likely candidates and then to make final detailed modifications and fine-tuning. Importantly, insights gained about the design should be seen as a compliment, not a replacement, for the prosthetist's skill and experience. We propose instead that this method might reduce the time spent on the early stages of socket design and allow prosthetists to focus on the most skilled and creative tasks of fine-tuning the design, in face-to-face consultation with their client.


Subject(s)
Algorithms , Prosthesis Design , Artificial Limbs , Automation , Humans , Pressure
8.
J Tissue Viability ; 28(4): 186-193, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31668875

ABSTRACT

Pressure ulcers (PUs) represent a substantial burden to both patients and healthcare providers. Accordingly, effective prevention strategies should follow early detection of PUs. Anaerobic metabolites, such as lactate and pyruvate, are promising noninvasive biomarkers indicative of tissue ischaemia, one of the major mechanisms leading to PU development. The aim of this study was to investigate if the temporal release profile of these metabolites in sweat and sebum is sensitive to detect local tissue changes resulting from prolonged mechanical loads. The sacrum of healthy volunteers was subjected to two different loading protocols. After a baseline measurement, the left and right side of the sacrum were subjected to continuous and intermittent loading regimen, respectively, at a pressure of 100 mmHg. Biomarker samples were collected every 20 min, with a total experimental time of 140 min. Sweat was collected at 37 ∘C and 80% relative humidity, and sebum at ambient conditions, from 11 to 13 volunteers, respectively. Both samples were analysed for lactate and pyruvate concentrations using ultra-high performance supercritical fluid chromatography mass spectrometry. Prior to analysis metabolite concentrations were normalized to individual baseline levels and, in the case of sweat, additional normalization was performed to an unloaded control site to account for fatigue of sweat glands. Although substantial variability was present, the temporal release profiles of both sweat and sebum metabolites reflected the applied loading regimen with increased levels upon load application, and recovery to baseline levels following load removal. Highest relative increases were 20% and 30% for sweat lactate and pyruvate, respectively, and 41% for sebum lactate. Sebum pyruvate was not present in quantifiable amounts. There was a linear correlation between the individual responses to intermittent and continuous loading. The present study revealed that metabolite biomarkers in both sweat and sebum were sensitive to the application of mechanical loads, indicative of local ischaemia within skin and soft tissues. Similar trends in metabolic biomarkers were observed in response to intermittent and continuous loading regimens in both sweat and sebum. Metabolites represent a potential means to monitor the health of loaded skin and soft tissues informing timely interventions of PU prevention.


Subject(s)
Anaerobiosis/physiology , Biomarkers/analysis , Pressure Ulcer/metabolism , Sebum/metabolism , Skin/metabolism , Sweat/metabolism , Adult , Aged , Biomarkers/metabolism , Female , Healthy Volunteers , Humans , Male , Middle Aged , Pressure Ulcer/physiopathology , Skin/physiopathology , United Kingdom , Weight-Bearing/physiology
9.
Clin Biomech (Bristol, Avon) ; 67: 70-77, 2019 07.
Article in English | MEDLINE | ID: mdl-31077978

ABSTRACT

BACKGROUND: In recent years, it has become increasingly apparent that medical device-related pressure ulcers represent a significant burden to both patients and healthcare providers. Medical devices can cause damage in a variety of patients from neonates to community based adults. To date, devices have typically incorporated generic designs with stiff polymer materials, which impinge on vulnerable soft tissues. As a result, medical devices that interact with the skin and underlying soft tissues can cause significant deformations due to high interface pressures caused by strapping or body weight. METHODS: This review provides a detailed analysis of the latest bioengineering tools to assess device related skin and soft tissue damage and future perspectives on the prevention of these chronic wounds. This includes measurement at the device-skin interface, imaging deformed tissues, and the early detection of damage through biochemical and biophysical marker detection. In addition, we assess the potential of computational modelling to provide a means for device design optimisation and material selection. INTERPRETATION: Future collaboration between academics, industrialists and clinicians should provide the basis to improve medical device design and prevent the formation of these potentially life altering wounds. Ensuring clinicians report devices that cause pressure ulcers to regulatory agencies will provide the opportunity to identify and improve devices, which are not fit for purpose.


Subject(s)
Bioengineering/methods , Pressure Ulcer/prevention & control , Body Weight , Computer Simulation , Humans , Polymers/chemistry , Pressure , Pressure Ulcer/etiology , Prosthesis Design , Respiration, Artificial/adverse effects , Skin/pathology
10.
J Tissue Viability ; 28(1): 1-6, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30638732

ABSTRACT

Pressure ulcers (PUs) are a major burden to both patients, carers and the healthcare system. It is therefore important to identify patients at risk and detect pressure ulcers at an early stage of their development. The pro-inflammatory cytokine IL-1α is a promising indicator of tissue damage. The aim of this study was to compare the temporal skin response, by means of IL-1α expression, to different loading regimens and to investigate the presence of individual variability. The sacrum of eleven healthy volunteers was subjected to two different loading protocols. After a baseline measurement, the left and right side of the sacrum were subjected to continuous and intermittent loading regimen, respectively, at a pressure of 100 mmHg. Data was collected every 20 min, allowing for a total experimental time of 140 min. Sebum, collected at ambient conditions using Sebutape, was analyzed for the pro-inflammatory cytokine IL-1α. Most robust results were obtained using a baseline normalization approach on individual data. The IL-1α level significantly changed upon load application and removal (p<0.05) for both loading regimens. Highest IL-1α ratio increase, 3.7-fold, was observed for 1 h continuous loading. During the refractory periods for both loading regimen the IL-1α levels were still found to be up-regulated compared to baseline (p<0.05). The IL-1α level increased significantly for the two initial loading periods (p<0.05), but stabilized during the final loading period for both loading regimens. Large individual variability in IL-1α ratio was observed in the responses, with median values of 1.91 (range 1.49-3.08), and 2.52 (range 1.96-4.29), for intermittent and continuous loading, respectively, although the differences were not statistically significant. Cluster analysis revealed the presence of two distinct sub-populations, with either a low or high response to the applied loading regimen. The measurement after the first loading period proved to be representative for the subsequent measurements on each site. This study revealed that trends in normalized IL-1α provided an early indicator for tissue status following periods of mechanical loading and refractory unloaded conditions. Additionally, the observed individual variability in the response potentially identifies patients at risk of developing PUs.


Subject(s)
Interleukin-1alpha/analysis , Pressure Ulcer/etiology , Skin/injuries , Stress, Mechanical , Adult , Aged , Female , Humans , Interleukin-1alpha/blood , Male , Middle Aged
11.
J Tissue Viability ; 26(3): 180-188, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28602246

ABSTRACT

Prolonged mechanical loading can lead to the breakdown of skin and underlying tissues which can, in turn, develop into a pressure ulcer. The benefits of pressure relief and/or redistribution to minimise risk have been well documented. Manufacturers have developed alternating air pressure mattresses (APAMs) to provide periodic relief for individuals on prolonged bed-rest. The present study describes the development of a control system, termed Pneumatic Manager which can vary the signature of an APAM, namely its pressure amplitude, cell profile and cycle period. An experimental array was designed to investigate the effects of varying these parameters, particularly with respect to its ability to maintain skin viability in a group of five healthy volunteers lying in a supine position. Transcutaneous gas (TcPO2/TcPCO2) tensions at the sacrum were monitored. In addition, pressures and microclimate parameters at the loaded support interface were also measured. In the majority of test conditions the alternating support produced sacral TcPO2 values, which either remained relatively high or fluctuated in concert with cycle period providing adequate viability. However, in 46% of cases at the extreme pressure amplitude of 100/0 mmHg, there was compromise to the skin viability at the sacrum, as reflected in depressed TcPO2 levels associated with an elevation of TcPCO2 levels above the normal range. In all cases, both the humidity and temperature levels increased during the test period. It is interesting to note that interface pressures at the sacrum rarely exceeded 60 mmHg. Although such studies need to be extended to involve bed-bound individuals, the results provide a design template for the optimum pressure signatures of APAM systems to ensure maintenance of skin viability during pronged loading.


Subject(s)
Beds/standards , Pressure/adverse effects , Transducers, Pressure/statistics & numerical data , Weights and Measures/instrumentation , Adult , Equipment Design/standards , Female , Humans , Male , Pressure Ulcer/physiopathology , Pressure Ulcer/prevention & control , Sacrococcygeal Region/blood supply , Sacrococcygeal Region/physiopathology
12.
Med Eng Phys ; 43: 1-18, 2017 05.
Article in English | MEDLINE | ID: mdl-28285881

ABSTRACT

The care and rehabilitation of individuals after lower limb amputation presents a substantial and growing socioeconomic challenge. Clinical outcome is closely linked to successful functional rehabilitation with a prosthetic limb, which depends upon comfortable prosthetic limb - residual limb load transfer. Despite early interest in the 1980s, the amputated limb has received considerably less attention in computational biomechanical analysis than other subjects, such as arthroplasty. This systematic literature review investigates the state of the art in residual limb finite element analysis published since 2000. The identified studies were grouped into the following categories: (1) residuum-prosthesis interface mechanics; (2) residuum soft tissue internal mechanics; (3) identification of residuum tissue characteristics; (4) proposals for incorporating FEA into the prosthesis fitting process; (5) analysis of the influence of prosthetic componentry concepts to improve load transfer to the residuum, such as the monolimb and structural socket compliance; and (6) analysis of osseointegrated (OI) prostheses. The state of the art is critically appraised in order to form recommendations for future modeling studies in terms of geometry, material properties, boundary conditions, interface models, and relevant but un-investigated issues. Finally, the practical implementation of these approaches is discussed.


Subject(s)
Amputation, Surgical , Artificial Limbs , Finite Element Analysis , Humans , Mechanical Phenomena , Osseointegration , Prosthesis Design
13.
Clin Biomech (Bristol, Avon) ; 40: 27-32, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27794259

ABSTRACT

BACKGROUND: Individuals with impaired mobility can spend prolonged periods on support surfaces, increasing their risk of developing pressure ulcers. Manufacturers have developed mattresses to maximise contact area. The present study evaluated both the biomechanical and physiological responses to lying postures on a Fluid Immersion Simulation mattress. METHODS: Seventeen healthy participants were recruited to evaluate the mattress during three prescribed settings of immersion (high, medium and low). Parameters reflecting biomechanical and physiological responses, and the microclimate were monitored during three postures (supine, lateral and high-sitting) over a 90minute test session. Transcutaneous oxygen and carbon dioxide gas responses were categorised according to three criteria and data were compared between each condition. FINDINGS: Results indicated that interface pressures remained consistent, with peak sacral values ranging from 21 to 27mmHg across all immersion settings and postures. The majority of participants (82%) exhibited minimal changes in gas tensions at the sacrum during all test conditions. By contrast, three participants exhibited decreased oxygen with increased carbon dioxide tensions for all three immersion settings. Supine and high sitting sacral microclimate values ranged between 30.1-30.6°C and 42.3-44.5% for temperature and relative humidity respectively. During lateral tilt there was a reduction of 1.7-2.5°C and 3.3-5.3% in these values. The majority of participants reported high comfort scores, although a few experienced bottoming out during the high-sitting posture at the high immersion setting. INTERPRETATION: Fluid Immersion Simulation provides an intelligent approach to increase the support area. Further research is required to provide evidence based guidance on the use of personalised support surfaces.


Subject(s)
Beds , Pressure Ulcer/prevention & control , Pressure/adverse effects , Adult , Aged , Aged, 80 and over , Blood Gas Monitoring, Transcutaneous , Carbon Dioxide/blood , Cross-Over Studies , Female , Humans , Male , Middle Aged , Oxygen/blood , Posture/physiology , Sacrum/physiology , Temperature , Young Adult
14.
Med Eng Phys ; 38(9): 895-903, 2016 09.
Article in English | MEDLINE | ID: mdl-27245749

ABSTRACT

It is proposed that direct mechanical loading can impair dermal lymphatic function, contributing to the causal pathway of pressure ulcers. The present study aims to investigate the effects of loading on human dermal lymphatic vessels. Ten participants were recruited with ages ranging from 24 to 61 years. Participants had intradermal Indocyanine Green injections administrated between left finger digits. Fluorescence was imaged for 5min sequences with an infra-red camera prior to lymph vessel loading, immediately after axial loading (60mmHg) and following a recovery period. Image processing was employed to defined transient lymph packets and compare lymph function between each test phase. The results revealed that between 1-8 transient events (median=4) occurred at baseline, with a median velocity of 8.1mm/sec (range 4.1-20.1mm/sec). Immediately post-loading, there was a significant (p<0.05) reduction in velocity (median=6.4, range 2.2-13.5mm/sec), although the number of transient lymph packages varied between participants. During the recovery period the number (range 1-7) and velocity (recovery median=9.6mm/sec) of transient packets were largely restored to basal values. The present study revealed that some individuals present with impaired dermal lymphatic function immediately after uniaxial mechanical loading. More research is needed to investigate the effects of pressure and shear on lymphatic vessel patency.


Subject(s)
Dermis/blood supply , Lymphatic Vessels/physiology , Vasoconstriction , Adult , Biomechanical Phenomena , Female , Humans , Image Processing, Computer-Assisted , Lymphatic Vessels/diagnostic imaging , Male , Middle Aged , Optical Imaging , Weight-Bearing , Young Adult