1.
J Surg Res ; 293: 618-624, 2024 01.
Article in English | MEDLINE | ID: mdl-37837817

ABSTRACT

INTRODUCTION: Current imaging techniques have several limitations in detecting parathyroid glands. We have investigated the calcium-sensing receptor (CaSR) as a potential target for specifically labeling parathyroid glands for radiologic detection. For accurate imaging it is vital that a large differential expression exists between the target tissue and adjacent structures. We sought to investigate the relative abundance of the CaSR in normal and abnormal parathyroid tissue, as well as normal and abnormal thyroid. METHODS: Existing clinical specimens were selected that represented a wide variety of pathologically and clinically confirmed malignant and benign thyroid and parathyroid specimens. Sections were stained for the CaSR using immunohistochemistry and scored for intensity and abundance of expression. (H score = intensity scored from 0 to 3 multiplied by the % of cells at each intensity. Range 0-300). RESULTS: All parathyroid specimens expressed the CaSR to a high degree. Normal parathyroid had the highest H score (271, s.d. 25.4). Abnormal parathyroid specimens were slightly lower but still much higher than normal thyroid (H score 38.3, s.d. 23.3). Medullary thyroid cancer also expressed the CaSR significantly higher than normal thyroid (H score 182, s.d. 69.1, P < 0.001) but below parathyroid levels. Hürthle cell carcinoma expressed the CaSR to a lesser degree but higher than normal thyroid (H score 101, s.d. 46.4, P = 0.0037). CONCLUSIONS: The CaSR is differentially expressed on parathyroid tissue making it a feasible target for parathyroid imaging. False positives might be anticipated with medullary and Hürthle cell cancers.


Subject(s)
Carcinoma, Neuroendocrine , Thyroid Neoplasms , Humans , Carcinoma, Neuroendocrine/pathology , Parathyroid Glands/diagnostic imaging , Parathyroid Glands/metabolism , Receptors, Calcium-Sensing/analysis , Receptors, Calcium-Sensing/metabolism , Thyroid Neoplasms/pathology
2.
J Am Soc Mass Spectrom ; 29(2): 297-303, 2018 02.
Article in English | MEDLINE | ID: mdl-28895085

ABSTRACT

A simple design for an open port sampling interface coupled to electrospray ionization (OPSI-ESI) is presented for the analysis of organic aerosols. The design uses minimal modifications to a Bruker electrospray (ESI) emitter to create a continuous flow, self-aspirating open port sampling interface. Considerations are presented for introducing aerosol to the open port sampling interface including aerosol gas flow and solvent flow rates. The device has been demonstrated for use with an aerosol of nicotine as well as aerosol formed in the pyrolysis of biomass. Upon comparison with extractive electrospray ionization (EESI), this device has similar sensitivity with increased reproducibility by nearly a factor of three. The device has the form factor of a standard Bruker/Agilent ESI emitter and can be used without any further instrument modifications. Graphical Abstract ᅟ.