Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Preprint in English | medRxiv | ID: ppmedrxiv-22277366

ABSTRACT

ObjectivesTo assess the performances of three commonly used rapid antigen diagnostic tests (Ag-RDTs) used as self-tests in asymptomatic individuals in the Omicron period. DesignCross-sectional diagnostic test accuracy study. SettingThree public health service COVID-19 test sites in the Netherlands. Participants3,600 asymptomatic individuals aged [≥]16 years presenting for SARS-CoV-2 testing for any reason except confirmatory testing after a positive self-test. InterventionsParticipants were sampled for RT-PCR (reference test) and received one self-test (either Acon Flowflex (Flowflex), MP Biomedicals (MPBio), or Siemens-Healthineers Clinitest (Clinitest)) to perform unsupervised at home within three hours and blinded to the RT-PCR result. Main Outcome(s) and Measures(s)Diagnostic accuracies (sensitivity, specificity, positive and negative predictive values) of each self-test compared to RT-PCR. ResultsOverall sensitivities of the three self-tests were 27.5% (95% CI: 21.3-34.3%) for Flowflex, 20.9% (13.9-29.4%) for MPBio, and 25.6% (19.1-33.1%) for Clinitest. After applying a viral load cut-off ([≥]5.2 log10 SARS-CoV-2 E-gene copies/mL), sensitivities increased to 48.3% (95% CI: 37.6-59.2%), 37.8% (22.5-55.2%), and 40.0% (29.5-51.2%), respectively. No consistent differences were found in sensitivities by COVID-19 vaccination status, having had a prior SARS-CoV-2 infection, gender or age across the three self-tests. Specificities were >99% for all tests in most analyses. ConclusionsThe sensitivities of three commonly used SARS-CoV-2 Ag-RDTs when used as self-tests in asymptomatic individuals in the Omicron period, were very low. Our findings indicate that Ag-RDT self-testing in asymptomatic individuals may only detect the minority of infections at that point in time and may not be sufficient to prevent the spreading of the virus to other (vulnerable) persons. Repeated self-testing in case of a negative self-test is advocated to improve the diagnostic yield of the self-tests, and individuals should certainly be advised to re-test when symptoms develop. Summary boxO_ST_ABSWhat is already known on this topicC_ST_ABSO_LIIf sufficiently reliable, SARS-CoV-2 self-testing by asymptomatic persons prior to admission in places where groups gather could have a huge public health impact by lowering the reproduction number or keep it below one for longer periods. C_LIO_LICurrent evidence suggests that SARS-CoV-2 rapid antigen diagnostic tests (Ag-RDTs) when used as self-tests by asymptomatic individuals perform suboptimal, but sample sizes of the previous studies were too small to draw robust conclusions, and also empirical data on the accuracy of Ag-RDT self-tests in asymptomatic individuals during the Omicron period are scarce. C_LI What this study addsO_LICompared to RT-PCR testing, overall sensitivities of three commercially available SARS-CoV-2 Ag-RDTs when used as self-tests by asymptomatic individuals (primary analysis population of non-confirmatory testers; n= 3600, 87% of full analysis population) in the Omicron period, were very low: 27.5% (95% CI: 21.3-34.3%) for the Acon Flowflex test, 20.9% (13.9-29.4%) for the MP Biomedicals test, and 25.6% (19.1-33.1%) for the Siemens Healthineers Clinitest Ag-RDT, which increased to 48.3% (95% CI: 37.6-59.2%), 37.8% (22.5-55.2%), and 40.0% (29.5-51.2%), respectively, when applying a viral load cut-off ([≥]5.2 log10 SARS-CoV-2 E-gene copies/mL). C_LIO_LIOur findings indicate that Ag-RDT self-testing in asymptomatic individuals may only detect the minority of infections at that point in time and may not be sufficient to prevent the spreading of the virus to other (vulnerable) persons. Repeated self-testing in case of a negative self-test is advocated to improve the diagnostic yield of the self-tests, and individuals should certainly be advised to re-test when symptoms develop. C_LI

2.
Preprint in English | medRxiv | ID: ppmedrxiv-21253874

ABSTRACT

BackgroundPre-/asymptomatic close contacts of SARS-CoV-2 infected individuals were tested at day 5 after contact by real-time reverse transcriptase polymerase chain reaction (RT-PCR). Diagnostic accuracy of antigen-detecting rapid diagnostic tests (Ag-RDT) in pre-/asymptomatic close contacts was up till now unknown. MethodsWe performed a prospective cross-sectional diagnostic test accuracy study. Close contacts (e.g. selected via the test-and-trace program or contact tracing app) aged [≥]16 years and asymptomatic when requesting a test, were included consecutively and tested at day 5 at four Dutch public health service test sites. We evaluated two Ag-RDTs (BD Veritor System Ag-RDT (BD), and Roche/SD Biosensor Ag-RDT (SD-B)) with RT-PCR as the reference standard. Virus culture was performed in RT-PCR positive individuals to determine the viral load cut-off above which 95% was culture positive, as a proxy of infectiousness. ResultsOf 2,678 BD-tested individuals, 233 (8.7%) were RT-PCR positive and BD detected 149 (sensitivity 63.9%; 95% confidence interval 57.4%-70.1%). Out of 1,596 SD-B-tested individuals, 132 (8.3%) were RT-PCR positive and SD-B detected 83 (sensitivity 62.9%; 54.0%-71.1%). When applying an infectiousness viral load cut-off [≥] 5.2 log10 gene copies/mL, the sensitivity was 90.1% (84.2%-94.4%) for BD, 86.8% (78.1% to 93.0%) for SD-B overall, and 88.1% (80.5%-93.5%) for BD, 85.1% (74.3%-92.6%) for SD-B for those still asymptomatic at the actual time of sampling. Specificity was >99% for both Ag-RDTs in all analyses. ConclusionsThe sensitivity for detecting SARS-CoV-2 of both Ag-RDTs in pre-/asymptomatic close contacts is over 60%, increasing to over 85% after applying an infectiousness viral load cut-off. Trial registration numberNot applicable. A study protocol is available upon request.

SELECTION OF CITATIONS
SEARCH DETAIL
...