Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Inorg Chem ; 61(26): 9897-9905, 2022 Jul 04.
Article in English | MEDLINE | ID: mdl-35730617

ABSTRACT

A substituent decorating strategy for modification of the functional cavity is of great importance in the design of metal-organic frameworks (MOFs). Herein, three new isostructural cationic MOFs, [Cu3(Xpip)2]·NO3·nH2O (Xpip stands for X-substituted phenylimidazophenanthroline, where X = adm (SCNU-2), f (SCNU-3), and none for SCNU-4), have been successfully synthesized and shown gyroidal utc-c topology and large pore sizes which can be adjusted by different substituents (-N(CH3)2, -F, and -H). Interestingly, the differences of the substituents (sizes and proton donor/acceptor) show essential effects on the adsorption abilities of carbon dioxide and dyes, where SCNU-4 exhibits the highest CO2 affinity and the biggest adsorption capacity for anionic dyes Fluorescein Sodium, and SCNU-3 adsorbs the largest amount (1503.6 mg/g) of Acid Fuchsin to date for the reported porous materials. The detailed studies in adsorption kinetics, adsorption isotherms, and theoretical calculation of the binding energies between the structures and dye molecules confirm that the electric properties of the frameworks (cationic) and substituents directed to the pore surface are two important factors dramatically affecting the selective dye adsorption.

2.
Biosens Bioelectron ; 117: 175-182, 2018 Oct 15.
Article in English | MEDLINE | ID: mdl-29902633

ABSTRACT

Here we report an electrochemical immunoassay platform called Proton-ELISA (H-ELISA) for the detection of bioanalytes. H-ELISA uniquely utilizes protons as an immunoassay detection medium, generated by the enzyme glucose oxidase (GOx) coupled with Fenton's reagent in a proton amplification reaction cascade that results in a highly amplified signal. A proton-sensitive dual-gated ion-sensitive field effect transistor (DG-ISFET) sensor was also developed for sensitive and accurate detection of the proton signal in H-ELISA. The DG-ISFET sensor comprises of a 128 × 128 array of 16,384 sensing transistors each with an individually addressable back gate to allow for a very high signal throughput and improved accuracy. We then demonstrated that the platform could detect C-reactive protein and immunoglobulin E down to concentrations of 12.5 and 125 pg/mL, respectively. We further showed that the platform is compatible with complex biological sample conditions such as human serum, suggesting that the platform is sufficiently robust for potential diagnostic applications.


Subject(s)
Blood Chemical Analysis/methods , C-Reactive Protein/analysis , Electrochemical Techniques , Enzyme-Linked Immunosorbent Assay , Immunoassay/methods , Immunoglobulin E/analysis , Protons , Glucose Oxidase/metabolism , Humans , Immunoglobulin E/blood , Ions/chemistry , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL
...