Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 67
Filter
1.
Angew Chem Int Ed Engl ; : e202411503, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38985723

ABSTRACT

Anisotropy is crucial for birefringence (Δn) in optical materials, but optimizing it remains a formidable challenge (Δn > 0.3). Supramolecular frameworks incorporating π-conjugated components are promising for achieving enhanced birefringence since their structural diversity and inherent anisotropy. Herein, we first synthesized (C6H6NO2)+Cl- (NAC). And then constructed a halogen bonded supramolecular framework I+(C6H4NO2)- (INA) by halogen aliovalent substitution of Cl- with I+. The organic moieties are protonated and deprotonated nicotinic acid (NA), respectively. The antiparallel arrangement of birefringent-active units in NAC and INA leads to significant differences in bonding characteristics between interlayer and intralayer domains. Moreover, [O···I+···N] halogen bond in 1D [I+(C6H4NO2)-] chain exhibits stronger interactions and stricter directionality, resulting in a more pronounced in-plane anisotropy between the intrachain and interchain directions. Consequently, INA exhibits exceptional birefringent performance, with a value of 0.778 at 550 nm, twice that of NAC (0.363 at 550 nm). This value significantly exceeds those of commercial birefringent crystals, such as CaCO3 (0.172 at 546 nm), and is the highest reported value among ultraviolet birefringent crystals. This work presents a novel design strategy that employs halogen bonds as connection sites and modes for birefringent-active units, opening new avenues for developing high-performance birefringent crystals.

2.
Dalton Trans ; 53(25): 10536-10543, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38842192

ABSTRACT

Herein, the first F-containing iodate-phosphate, namely Ba2Ga2F6(IO3)(PO4), was prepared via a hydrothermal reaction, in which HPF6 (70 wt% solution in water) was used as the source of both fluoride and phosphate anions for the first time. Ba2Ga2F6(IO3)(PO4) features an unprecedented 1D [Ga2F6(IO3)(PO4)]4- helix chain, composed of a 1D Ga(1)(IO3)O4F chain via the bridging of 0D Ga(2)(PO4)F5. The UV-Vis spectrum shows that Ba2Ga2F6(IO3)(PO4) has a wide bandgap with a short-UV absorption edge (4.35 eV; 253 nm). Birefringence measurement under a polarizing microscope shows that Ba2Ga2F6(IO3)(PO4) displays a moderate birefringence of 0.072@550 nm, which is consistent with the value (0.070@550 nm) obtained by DFT calculations, indicating that Ba2Ga2F6(IO3)(PO4) has potential applications as a short-UV birefringent material. This study highlights the crucial role played by the incorporation of specific functional groups into compounds, shedding light on their contribution to promising inorganic functional materials.

3.
Entropy (Basel) ; 26(6)2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38920533

ABSTRACT

Network topology plays a key role in determining the characteristics and dynamical behaviors of a network. But in practice, network topology is sometimes hidden or uncertain ahead of time because of network complexity. In this paper, a robust-synchronization-based topology observer (STO) is proposed and applied to solve the problem of identifying the topology of complex delayed networks (TICDNs). In comparison to the existing literature, the proposed STO does not require any prior knowledge about the range of topological parameters and does not have strict limits on topology type. Furthermore, the proposed STO is suitable not only for networks with fixed coupling strength, but also for networks with adaptive coupling strength. Finally, a few comparison examples for TICDNs are used to verify the feasibility and efficiency of the proposed STO, and the results show that the proposed STO outperforms the other methods.

4.
Photoacoustics ; 38: 100615, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38817689

ABSTRACT

Background: Accurate assessment of Rheumatoid Arthritis (RA) activity remains a challenge. Multimodal photoacoustic/ultrasound (PA/US) joint imaging emerges as a novel imaging modality capable of depicting microvascularization and oxygenation levels in inflamed joints associated with RA. However, the scarcity of large-scale studies limits the exploration of correlating joint oxygenation status with disease activity. Objective: This study aimed to explore the correlation between multimodal PA/US imaging scores and RA disease activity, assessing its clinical applicability in managing RA. Methods: In this study, we recruited 111 patients diagnosed with RA and conducted examinations of seven small joints on their clinically dominant side using a PA/US imaging system. The PA and power Doppler ultrasound (PDUS) signals were semi-quantitatively assessed using a 0-3 grading system. The cumulative scores for PA and PDUS across these seven joints (PA-sum and PDUS-sum) were calculated. Relative oxygen saturation (So2) values of inflamed joints on the clinically dominant side were measured, and categorized into four distinct PA+So2 patterns. The correlation between PA/US imaging scores and disease activity indices was systematically evaluated. Results: Analysis of 777 small joints in 111 patients revealed that the PA-sum scores exhibited a strong positive correlation with standard clinical scores for RA, including DAS28 [ESR] (ρ = 0.682), DAS28 [CRP] (ρ = 0.683), CDAI (ρ = 0.738), and SDAI (ρ = 0.739), all with p < 0.001. These correlations were superior to those of the PDUS-sum scores (DAS28 [ESR] ρ = 0.559, DAS28 [CRP] ρ = 0.555, CDAI ρ = 0.575, SDAI ρ = 0.581, p < 0.001). Significantly, in patients with higher PA-sum scores, notable differences were observed in the erythrocyte sedimentation rate (ESR) (p < 0.01) and swollen joint count 28 (SJC28) (p < 0.01) between hypoxia and intermediate groups. Notably, RA patients in the hypoxia group exhibited higher clinical scores in certain clinical indices. Conclusion: Multi-modal PA/US imaging introduces potential advancements in RA assessment, especially regarding So2 evaluations in synovial tissues and associated PA scores. However, further studies are warranted, particularly with more substantial sample sizes and in multi-center settings. Summary: This study utilized multi-modal PA/US imaging to analyze Rheumatoid Arthritis (RA) patients' synovial tissues and affected joints. When juxtaposed with traditional PDUS imaging, the PA approach demonstrated enhanced sensitivity, especially concerning detecting small vessels in thickened synovium and inflamed tendon sheaths. Furthermore, correlations between the derived PA scores, PA+So2 patterns, and standard clinical RA scores were observed. These findings suggest that multi-modal PA/US imaging could be a valuable tool in the comprehensive assessment of RA, offering insights not only into disease activity but also into the oxygenation status of synovial tissues. However, as promising as these results are, further investigations, especially in larger and diverse patient populations, are imperative. Key points: ⸸ Multi-modal PA/US Imaging in RA: This novel technique was used to assess the So2 values in synovial tissues and determine PA scores of affected RA joints.⸸ Correlation significantly with Clinical RA Scores: Correlations significantly were noted between PA scores, PA+So2 patterns, and standard clinical RA metrics, hinting at the potential clinical applicability of the technique.

5.
Photoacoustics ; 38: 100606, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38665366

ABSTRACT

Background: The differentiation between benign and malignant breast tumors extends beyond morphological structures to encompass functional alterations within the nodules. The combination of photoacoustic (PA) imaging and radiomics unveils functional insights and intricate details that are imperceptible to the naked eye. Purpose: This study aims to assess the efficacy of PA imaging in breast cancer radiomics, focusing on the impact of peritumoral region size on radiomic model accuracy. Materials and methods: From January 2022 to November 2023, data were collected from 358 patients with breast nodules, diagnosed via PA/US examination and classified as BI-RADS 3-5. The study used the largest lesion dimension in PA images to define the region of interest, expanded by 2 mm, 5 mm, and 8 mm, for extracting radiomic features. Techniques from statistics and machine learning were applied for feature selection, and logistic regression classifiers were used to build radiomic models. These models integrated both intratumoral and peritumoral data, with logistic regressions identifying key predictive features. Results: The developed nomogram, combining 5 mm peritumoral data with intratumoral and clinical features, showed superior diagnostic performance, achieving an AUC of 0.950 in the training cohort and 0.899 in validation. This model outperformed those based solely on clinical features or other radiomic methods, with the 5 mm peritumoral region proving most effective in identifying malignant nodules. Conclusion: This research demonstrates the significant potential of PA imaging in breast cancer radiomics, especially the advantage of integrating 5 mm peritumoral with intratumoral features. This approach not only surpasses models based on clinical data but also underscores the importance of comprehensive radiomic analysis in accurately characterizing breast nodules.

6.
J Clin Transl Hepatol ; 12(4): 333-345, 2024 Apr 28.
Article in English | MEDLINE | ID: mdl-38638378

ABSTRACT

Background and Aims: The global prevalence of nonalcoholic fatty liver disease (NAFLD) is 25%. This study aimed to explore differences in the gut microbial community and blood lipids between normal livers and those affected by NAFLD using 16S ribosomal deoxyribonucleic acid sequencing. Methods: Gut microbiome profiles of 40 NAFLD and 20 non-NAFLD controls were analyzed. Information about four blood lipids and 13 other clinical features was collected. Patients were divided into three groups by ultrasound and FibroScan, those with a normal liver, mild FL (FL1), and moderate-to-severe FL (FL2). FL1 and FL2 patients were divided into two groups, those with either hyperlipidemia or non-hyperlipidemia based on their blood lipids. Potential keystone species within the groups were identified using univariate analysis and a specificity-occupancy plot. Significant difference in biochemical parameters ion NAFLD patients and healthy individuals were identified by detrended correspondence analysis and canonical correspondence analysis. Results: Decreased gut bacterial diversity was found in patients with NAFLD. Firmicutes/Bacteroidetes decreased as NAFLD progressed. Faecalibacterium and Ruminococcus 2 were the most representative fatty-related bacteria. Glutamate pyruvic transaminase, aspartate aminotransferase, and white blood cell count were selected as the most significant biochemical indexes. Calculation of areas under the curve identified two microbiomes combined with the three biochemical indexes that identified normal liver and FL2 very well but performed poorly in diagnosing FL1. Conclusions: Faecalibacterium and Ruminococcus 2, combined with glutamate pyruvic transaminase, aspartate aminotransferase, and white blood cell count distinguished NAFLD. We speculate that regulating the health of gut microbiota may release NAFLD, in addition to providing new targets for clinicians to treat NAFLD.

7.
Clin Breast Cancer ; 24(5): e379-e388.e1, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38548517

ABSTRACT

OBJECTIVES: To develop a nomogram based on photoacoustic imaging (PAI) radiomics and BI-RADs to identify breast cancer (BC) in BI-RADS 4 or 5 lesions detected by ultrasound (US). METHODS: In this retrospective study, 119 females with 119 breast lesions at US and PAI examination were included (January 2022 to December 2022). Patients were divided into the training set (n = 83) or testing set (n = 36) to develop a nomogram to identify BC in BI-RADS 4 or 5 lesions. Relevant factors at clinic, BI-RADS category, and PAI were reviewed. Univariate and multivariate regression was used to evaluate factors for associations with BC. To evaluate the diagnostic performance of nomogram, the area under the curve (AUC) of receiver operating characteristic curve, accuracy, specificity and sensitivity was employed. RESULTS: The nomogram that included BI-RADS category and PAI radiomics score demonstrated a high AUC of 0.925 (95%CI: 0.8467-0.9712) in the training set and 0.926 (95%CI: 0.846-1.000) in the test set. The nomogram also showed significantly better discrimination than the radiomics score (P = .048) or BI-RADS category (P = .009) in the training set. These significant differences were demonstrated in the testing set, outperform the radiomics score (P = .038) and BI-RADS category (P = .013). CONCLUSIONS: The nomogram developed with BI-RADS and PAI radiomics score can effectively identify BC in BI-RADS 4 or 5 lesions. This technique has the potential to further improve early diagnostic accuracy for BC.


Subject(s)
Breast Neoplasms , Nomograms , Photoacoustic Techniques , Ultrasonography, Mammary , Humans , Female , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Retrospective Studies , Middle Aged , Photoacoustic Techniques/methods , Adult , Ultrasonography, Mammary/methods , Aged , ROC Curve , Sensitivity and Specificity , Breast/diagnostic imaging , Breast/pathology , Radiomics
8.
Biosensors (Basel) ; 14(2)2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38391993

ABSTRACT

To address the need for high-resolution imaging in lung nodule detection and overcome the limitations of the shallow imaging depth associated with high-frequency ultrasound and the complex structure of lung tissue, we successfully integrated 50 MHz ultrasound transducers with 18-gauge biopsy needles. Featuring a miniaturized size of 0.6 × 0.5 × 0.5 mm3, the 50 MHz micromachined 1-3 composite transducer was tested to perform mechanical scanning of a nodule within a lung-tissue-mimicking phantom in vitro. The high-frequency transducer demonstrated the ability to achieve imaging with an axial resolution of 30 µm for measuring nodule edges. Moreover, the integrated biopsy needle prototype exhibited high accuracy (1.74% discrepancy) in estimating nodule area compared to actual dimensions in vitro. These results underscore the promising potential of biopsy-needle-integrated transducers in enhancing the accuracy of endoscopic ultrasound-guided fine needle aspiration biopsy (EUS-FNA) for clinical applications.


Subject(s)
Endoscopic Ultrasound-Guided Fine Needle Aspiration , Transducers , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Phantoms, Imaging
9.
Ultrasound Med Biol ; 50(5): 722-728, 2024 05.
Article in English | MEDLINE | ID: mdl-38369431

ABSTRACT

OBJECTIVE: Although ultrasound is a common tool for breast cancer screening, its accuracy is often operator-dependent. In this study, we proposed a new automated deep-learning framework that extracts video-based ultrasound data for breast cancer screening. METHODS: Our framework incorporates DenseNet121, MobileNet, and Xception as backbones for both video- and image-based models. We used data from 3907 patients to train and evaluate the models, which were tested using video- and image-based methods, as well as reader studies with human experts. RESULTS: This study evaluated 3907 female patients aged 22 to 86 years. The results indicated that the MobileNet video model achieved an AUROC of 0.961 in prospective data testing, surpassing the DenseNet121 video model. In real-world data testing, it demonstrated an accuracy of 92.59%, outperforming both the DenseNet121 and Xception video models, and exceeding the 76.00% to 85.60% accuracy range of human experts. Additionally, the MobileNet video model exceeded the performance of image models and other video models across all evaluation metrics, including accuracy, sensitivity, specificity, F1 score, and AUC. Its exceptional performance, particularly suitable for resource-limited clinical settings, demonstrates its potential for clinical application in breast cancer screening. CONCLUSIONS: The level of expertise reached by the video models was greater than that achieved by image-based models. We have developed an artificial intelligence framework based on videos that may be able to aid breast cancer diagnosis and alleviate the shortage of experienced experts.


Subject(s)
Breast Neoplasms , Deep Learning , Humans , Female , Breast Neoplasms/diagnostic imaging , Artificial Intelligence , Prospective Studies , Ultrasonography
10.
Clin Breast Cancer ; 24(4): e210-e218.e1, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38423948

ABSTRACT

BACKGROUND: Hypoxia is a hallmark of breast cancer (BC). Photoacoustic (PA) imaging, based on the use of laser-generated ultrasound (US), can detect oxygen saturation (So2) in the tissues of breast lesion patients. PURPOSE: To measure the oxygenation status of tissue in and on both sides of the lesion in breast lesion participants using a multimodal Photoacoustic/ultrasound (PA/US) imaging system and to determine the correlation between So2 measured by PA imaging and benign or malignant disease. MATERIALS AND METHODS: Multimodal PA/US imaging and gray-scale US (GSUS) of breast lesion was performed in consecutive breast lesion participants imaged in the US Outpatient Clinic between 2022 and 2023. Dual-wavelength PA imaging was used to measure the So2 value inside the lesion and on both sides of the tissue, and to distinguish benign from malignant lesions based on the So2 value. The ability of So2 to distinguish benign from malignant breast lesions was evaluated by the receiver operating characteristic curve (ROC) and the De-Long test. RESULTS: A total of 120 breast lesion participants (median age, 42.5 years) were included in the study. The malignant lesions exhibited lower So2 levels compared to benign lesions (malignant: 71.30%; benign: 83.81%; P < .01). Moreover, PA/US imaging demonstrates superior diagnostic results compared to GSUS, with an area under the curve (AUC) of 0.89 versus 0.70, sensitivity of 89.58% versus 85.42%, and specificity of 86.11% versus 55.56% at the So2 cut-off value of 78.85 (P < .001). The false positive rate in GSUS reduced by 30.75%, and the false negative rate diminished by 4.16% with PA /US diagnosis. Finally, the So2 on both sides tissues of malignant lesions are lower than that of benign lesions (P < .01). CONCLUSION: PA imaging allows for the assessment of So2 within the lesions of breast lesion patients, thereby facilitating a superior distinction between benign and malignant lesions.


Subject(s)
Breast Neoplasms , Oxygen Saturation , Photoacoustic Techniques , Ultrasonography, Mammary , Humans , Female , Photoacoustic Techniques/methods , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Breast Neoplasms/metabolism , Adult , Middle Aged , Ultrasonography, Mammary/methods , Aged , Breast/diagnostic imaging , Breast/pathology , ROC Curve , Diagnosis, Differential , Multimodal Imaging/methods
11.
Ultrasonics ; 138: 107245, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38232449

ABSTRACT

As the demand for clean energy becomes greater worldwide, there will also be an increasing demand for next generation nuclear power plants that incorporate advanced sensors and monitoring equipment. A major challenge posed by nuclear power plants is that, during normal operation, the reactor compartment is subjected to high operating temperatures and radiation flux. Diagnostic sensors monitoring such structures are also subject to temperatures reaching hundreds of degrees Celsius, which puts them at risk for heat degradation. In this work, the ability of carbon nanofibers to work in conjunction with a liquid metal as a photoacoustic transmitter was demonstrated at high temperatures. Fields metal, a Bi-In-Sn eutectic, and gallium are compared as acoustic mediums. Fields metal was shown experimentally to have superior performance over gallium and other reference cases. Under stimulation from a low fluence 6 ns pulse laser at 6 mJ/cm2 with 532 nm green light, the Fields metal transducer transmitted a 200 kHz longitudinal wave with amplitude >5.5 times that generated by a gallium transducer at 300 °C. Each high temperature test was conducted from a hot to cold progression, beginning as high as 300 °C, and then cooling down to 100 °C. Each test shows increasing signal amplitude of the liquid metal transducers as temperature decreases. Carbon nanofibers show a strong improvement over previously used candle-soot nanoparticles in both their ability to produce strong acoustic signals and absorb higher laser fluences up to 12 mJ/cm2.

12.
Article in English | MEDLINE | ID: mdl-38261605

ABSTRACT

OBJECTIVES: Rheumatoid arthritis (RA) is characterized by hypoxia in the synovial tissue. While photoacoustic imaging (PA) offers a method to evaluate tissue oxygenation in RA patients, studies exploring the link between extra-synovial tissue of wrist oxygenation and disease activity remain scarce. We aimed to assess synovial oxygenation in RA patients using a multimodal photoacoustic-ultrasound (PA/US) imaging system and establish its correlation with disease activity. METHODS: A retrospective study was conducted on 111 patients with RA and 72 healthy controls from 2022 to 2023. Dual-wavelength PA imaging quantified oxygen saturation (So2) levels in the synovial membrane and peri-wrist region. Oxygenation states were categorised as hyperoxia, intermediate oxygenation, and hypoxia based on So2 values. The association between oxygenation levels and the clinical disease activity index was evaluated using a one-way analysis of variance, complemented by the Kruskal-Wallis test with Bonferroni adjustment. RESULTS: Of the patients with RA, 39 exhibited hyperoxia, 24 had intermediate oxygenation, and 48 had hypoxia in the wrist extra-synovial tissue. All of the control participants exhibited the hyperoxia status. Oxygenation levels in patients with RA correlated with clinical metrics. Patients with intermediate oxygenation had a lower disease activity index compared with those with hypoxia and hyperoxia. CONCLUSION: A significant correlation exists between wrist extra-synovial tissue oxygenation and disease activity in patients with RA.

13.
BMC Med Inform Decis Mak ; 24(1): 1, 2024 01 02.
Article in English | MEDLINE | ID: mdl-38166852

ABSTRACT

BACKGROUND: The application of artificial intelligence (AI) in the ultrasound (US) diagnosis of breast cancer (BCa) is increasingly prevalent. However, the impact of US-probe frequencies on the diagnostic efficacy of AI models has not been clearly established. OBJECTIVES: To explore the impact of using US-video of variable frequencies on the diagnostic efficacy of AI in breast US screening. METHODS: This study utilized different frequency US-probes (L14: frequency range: 3.0-14.0 MHz, central frequency 9 MHz, L9: frequency range: 2.5-9.0 MHz, central frequency 6.5 MHz and L13: frequency range: 3.6-13.5 MHz, central frequency 8 MHz, L7: frequency range: 3-7 MHz, central frequency 4.0 MHz, linear arrays) to collect breast-video and applied an entropy-based deep learning approach for evaluation. We analyzed the average two-dimensional image entropy (2-DIE) of these videos and the performance of AI models in processing videos from these different frequencies to assess how probe frequency affects AI diagnostic performance. RESULTS: The study found that in testing set 1, L9 was higher than L14 in average 2-DIE; in testing set 2, L13 was higher in average 2-DIE than L7. The diagnostic efficacy of US-data, utilized in AI model analysis, varied across different frequencies (AUC: L9 > L14: 0.849 vs. 0.784; L13 > L7: 0.920 vs. 0.887). CONCLUSION: This study indicate that US-data acquired using probes with varying frequencies exhibit diverse average 2-DIE values, and datasets characterized by higher average 2-DIE demonstrate enhanced diagnostic outcomes in AI-driven BCa diagnosis. Unlike other studies, our research emphasizes the importance of US-probe frequency selection on AI model diagnostic performance, rather than focusing solely on the AI algorithms themselves. These insights offer a new perspective for early BCa screening and diagnosis and are of significant for future choices of US equipment and optimization of AI algorithms.


The research on artificial intelligence-assisted breast diagnosis often relies on static images or dynamic videos obtained from ultrasound probes with different frequencies. However, the effect of frequency-induced image variations on the diagnostic performance of artificial intelligence models remains unclear. In this study, we aimed to explore the impact of using ultrasound images with variable frequencies on AI's diagnostic efficacy in breast ultrasound screening. Our approach involved employing a video and entropy-based feature breast network to compare the diagnostic efficiency and average two-dimensional image entropy of the L14 (frequency range: 3.0-14.0 MHz, central frequency 9 MHz), L9 (frequency range: 2.5-9.0 MHz, central frequency 6.5 MHz) linear array probe and L13 (frequency range: 3.6-13.5 MHz, central frequency 8 MHz), and L7 (frequency range: 3-7 MHz, central frequency 4.0 MHz) linear array probes. The results revealed that the diagnostic efficiency of AI models differed based on the frequency of the ultrasound probe. It is noteworthy that ultrasound images acquired with different frequency probes exhibit different average two-dimensional image entropy, while higher average two-dimensional image entropy positively affect the diagnostic performance of the AI model. We concluded that a dataset with higher average two-dimensional image entropy is associated with superior diagnostic efficacy for AI-based breast diagnosis. These findings contribute to a better understanding of how ultrasound image variations impact AI-assisted breast diagnosis, potentially leading to improved breast cancer screening outcomes.


Subject(s)
Artificial Intelligence , Breast Neoplasms , Humans , Female , Entropy , Ultrasonography , Breast Neoplasms/diagnostic imaging , Algorithms
14.
Comput Methods Programs Biomed ; 245: 108039, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38266556

ABSTRACT

BACKGROUND: The risk of ductal carcinoma in situ (DCIS) identified by biopsy often increases during surgery. Therefore, confirming the DCIS grade preoperatively is necessary for clinical decision-making. PURPOSE: To train a three-classification deep learning (DL) model based on ultrasound (US), combining clinical data, mammography (MG), US, and core needle biopsy (CNB) pathology to predict low-grade DCIS, intermediate-to-high-grade DCIS, and upstaged DCIS. MATERIALS AND METHODS: Data of 733 patients with 754 DCIS cases confirmed by biopsy were retrospectively collected from May 2013 to June 2022 (N1), and other data (N2) were confirmed by biopsy as low-grade DCIS. The lesions were randomly divided into training (n=471), validation (n=142), and test (n = 141) sets to establish the DCIS-Net. Information on the DCIS-Net, clinical (age and sign), US (size, calcifications, type, breast imaging reporting and data system [BI-RADS]), MG (microcalcifications, BI-RADS), and CNB pathology (nuclear grade, architectural features, and immunohistochemistry) were collected. Logistic regression and random forest analyses were conducted to develop Multimodal DCIS-Net to calculate the specificity, sensitivity, accuracy, receiver operating characteristic curve, and area under the curve (AUC). RESULTS: In the test set of N1, the accuracy and AUC of the multimodal DCIS-Net were 0.752-0.766 and 0.859-0.907 in the three-classification task, respectively. The accuracy and AUC for discriminating DCIS from upstaged DCIS were 0.751-0.780 and 0.829-0.861, respectively. In the test set of N2, the accuracy and AUC of discriminating low-grade DCIS from upstaged low-grade DCIS were 0.769-0.987 and 0.818-0.939, respectively. DL was ranked from one to five in the importance of features in the multimodal-DCIS-Net. CONCLUSION: By developing the DCIS-Net and integrating it with multimodal information, diagnosing low-grade DCIS, intermediate-to high-grade DCIS, and upstaged DCIS is possible. It can also be used to distinguish DCIS from upstaged DCIS and low-grade DCIS from upstaged low-grade DCIS, which could pave the way for the DCIS clinical workflow.


Subject(s)
Breast Neoplasms , Calcinosis , Carcinoma, Ductal, Breast , Carcinoma, Intraductal, Noninfiltrating , Pathology, Surgical , Humans , Female , Carcinoma, Intraductal, Noninfiltrating/diagnostic imaging , Carcinoma, Intraductal, Noninfiltrating/surgery , Retrospective Studies , Mammography , Breast Neoplasms/diagnostic imaging
15.
Postgrad Med J ; 100(1183): 309-318, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38275274

ABSTRACT

BACKGROUND: The application of photoacoustic imaging (PAI), utilizing laser-induced ultrasound, shows potential in assessing blood oxygenation in breast nodules. However, its effectiveness in distinguishing between malignant and benign nodules remains insufficiently explored. PURPOSE: This study aims to develop nomogram models for predicting the benign or malignant nature of breast nodules using PAI. METHOD: A prospective cohort study enrolled 369 breast nodules, subjecting them to PAI and ultrasound examination. The training and testing cohorts were randomly divided into two cohorts in a ratio of 3:1. Based on the source of the variables, three models were developed, Model 1: photoacoustic-BIRADS+BMI + blood oxygenation, Model 2: BIRADS+Shape+Intranodal blood (Doppler) + BMI, Model 3: photoacoustic-BIRADS+BIRADS+ Shape+Intranodal blood (Doppler) + BMI + blood oxygenation. Risk factors were identified through logistic regression, resulting in the creation of three predictive models. These models were evaluated using calibration curves, subject receiver operating characteristic (ROC), and decision curve analysis. RESULTS: The area under the ROC curve for the training cohort was 0.91 (95% confidence interval, 95% CI: 0.88-0.95), 0.92 (95% CI: 0.89-0.95), and 0.97 (95% CI: 0.96-0.99) for Models 1-3, and the ROC curve for the testing cohort was 0.95 (95% CI: 0.91-0.98), 0.89 (95% CI: 0.83-0.96), and 0.97 (95% CI: 0.95-0.99) for Models 1-3. CONCLUSIONS: The calibration curves demonstrate that the model's predictions agree with the actual values. Decision curve analysis suggests a good clinical application.


Subject(s)
Breast Neoplasms , Nomograms , Photoacoustic Techniques , Humans , Female , Photoacoustic Techniques/methods , Breast Neoplasms/diagnostic imaging , Prospective Studies , Middle Aged , Adult , Ultrasonography, Mammary/methods , ROC Curve , Aged , Predictive Value of Tests , Diagnosis, Differential
16.
Article in English | MEDLINE | ID: mdl-37971905

ABSTRACT

Due to the rapid developments in materials science and fabrication techniques, wearable devices have recently received increased attention for biomedical applications, particularly in medical ultrasound imaging, sensing, and therapy. Ultrasound is ubiquitous in biomedical applications because of its non-invasive nature, nonionic radiating, high precision, and real-time capabilities. While conventional ultrasound transducers are rigid and bulky, flexible transducers can be conformed to curved body areas for continuous sensing without restricting tissue movement or transducer shifting. This article comprehensively reviews the application of flexible ultrasound transducers in the field of biomedical imaging, sensing, and therapy. First, we review the background of flexible ultrasound transducers. Following that, we discuss advanced materials and fabrication techniques for flexible ultrasound transducers and their enabling technology status. Lastly, we highlight and summarize some promising preliminary data with recent applications of flexible ultrasound transducers in biomedical imaging, sensing, and therapy. We also provide technical barriers, challenges, and future perspectives for further research and development.

17.
Int J Hyperthermia ; 40(1): 2263672, 2023.
Article in English | MEDLINE | ID: mdl-37806666

ABSTRACT

Mechanical high-intensity focused ultrasound (M-HIFU), which includes histotripsy, is a non-ionizing, non-thermal ablation technology that can be delivered by noninvasive methods. Because acoustic cavitation is the primary mechanism of tissue disruption, histotripsy is distinct from the conventional HIFU techniques resulting in hyperthermia and thermal injury. Phase I human trials have shown the initial safety and efficacy of histotripsy in treating patients with malignant liver tumors. In addition to tissue ablation, a promising benefit of M-HIFU has been stimulating a local and systemic antitumor immune response in preclinical models and potentially in the Phase I trial. Preclinical studies combining systemic immune therapies appear promising, but clinical studies of combinations have been complicated by systemic toxicities. Consequently, combining M-HIFU with systemic immunotherapy has been demonstrated in preclinical models and may be testing in future clinical studies. An additional alternative is to combine intratumoral M-HIFU and immunotherapy using microcatheter-placed devices to deliver both M-HIFU and immunotherapy intratumorally. The promise of M-HIFU as a component of anti-cancer therapy is promising, but as forms of HIFU are tested in preclinical and clinical studies, investigators should report not only the parameters of the energy delivered but also details of the preclinical models to enable analysis of the immune responses. Ultimately, as clinical trials continue, clinical responses and immune analysis of patients undergoing M-HIFU including forms of histotripsy will provide opportunities to optimize clinical responses and to optimize application and scheduling of M-HIFU in the context of the multi-modality care of the cancer patient.


Subject(s)
Carcinoma, Hepatocellular , High-Intensity Focused Ultrasound Ablation , Liver Neoplasms , Humans , High-Intensity Focused Ultrasound Ablation/methods , Immunotherapy
18.
BMC Med Inform Decis Mak ; 23(1): 174, 2023 09 04.
Article in English | MEDLINE | ID: mdl-37667320

ABSTRACT

BACKGROUND: This retrospective study aims to validate the effectiveness of artificial intelligence (AI) to detect and classify non-mass breast lesions (NMLs) on ultrasound (US) images. METHODS: A total of 228 patients with NMLs and 596 volunteers without breast lesions on US images were enrolled in the study from January 2020 to December 2022. The pathological results served as the gold standard for NMLs. Two AI models were developed to accurately detect and classify NMLs on US images, including DenseNet121_448 and MobileNet_448. To evaluate and compare the diagnostic performance of AI models, the area under the curve (AUC), accuracy, specificity and sensitivity was employed. RESULTS: A total of 228 NMLs patients confirmed by postoperative pathology with 870 US images and 596 volunteers with 1003 US images were enrolled. In the detection experiment, the MobileNet_448 achieved the good performance in the testing set, with the AUC, accuracy, sensitivity, and specificity were 0.999 (95%CI: 0.997-1.000),96.5%,96.9% and 96.1%, respectively. It was no statistically significant compared to DenseNet121_448. In the classification experiment, the MobileNet_448 model achieved the highest diagnostic performance in the testing set, with the AUC, accuracy, sensitivity, and specificity were 0.837 (95%CI: 0.990-1.000), 70.5%, 80.3% and 74.6%, respectively. CONCLUSIONS: This study suggests that the AI models, particularly MobileNet_448, can effectively detect and classify NMLs in US images. This technique has the potential to improve early diagnostic accuracy for NMLs.


Subject(s)
Artificial Intelligence , Breast , Humans , Retrospective Studies , Ultrasonography , Area Under Curve
19.
Am J Med Sci ; 366(6): 449-457, 2023 12.
Article in English | MEDLINE | ID: mdl-37716602

ABSTRACT

BACKGROUND: Hepatic fibrosis is a common pathological process in many chronic liver diseases. TXNDC5 has been shown to be involved in the progression of renal and pulmonary fibrosis. However, the role of TXNDC5 in hepatic fibrosis is unknown. The purpose of this study is to explore the role and mechanism of TXNDC5 in hepatic fibrosis. METHODS: We used TGF-ß1 to activate LX-2 cells and reduced TXNDC5 expression by short hairpin RNA. Cell viability was assessed by CCK-8 assay. Cell apoptosis was analyzed by flow cytometry or Tunel assay. The fibrosis-related proteins and endoplasmic reticulum stress (ERs)-related proteins were measured by western blot. ELISA was performed to detect COL1AL levels and MMP2/9 activities in cell medium. A mouse model of hepatic fibrosis was constructed by intraperitoneal injection of CCL4. HE and Masson staining were performed to assess fibrosis in mouse liver tissue. RESULTS: The results show that TXNDC5 was up-regulated in activated LX-2 cells and CCL4-induced hepatic fibrosis mice. Knockdown of TXNDC5 inhibited the viability of activated LX-2 cells and the production of collagen COL1A1. Knockdown of TXNDC5 promoted apoptosis of activated LX-2 cells. Mechanically, inhibition of TXNDC5 enhanced ERs, and the ERs inhibitor 4-Phenylbutyric acid (4-PBA) reversed the effect of TXNDC5 on activated LX-2 cells. More importantly, knockdown of TXNDC5 alleviated CCl4-induced hepatic fibrosis in mice. CONCLUSIONS: Knockdown of TXNDC5 may reduce hepatic fibrosis by regulating ERs, and targeting TXNDC5 seems to be a candidate treatment for hepatic fibrosis.


Subject(s)
Liver Cirrhosis , Transforming Growth Factor beta1 , Animals , Mice , Collagen , Disease Models, Animal , Endoplasmic Reticulum Stress , Fibrosis , Hepatic Stellate Cells/metabolism , Liver Cirrhosis/chemically induced , Liver Cirrhosis/drug therapy , Transforming Growth Factor beta1/metabolism
20.
Chem Sci ; 14(35): 9533-9542, 2023 Sep 13.
Article in English | MEDLINE | ID: mdl-37712033

ABSTRACT

In this study, we identify a novel class of second-order nonlinear optical (NLO) crystals, non-π-conjugated piperazine (H10C4N2, PIP) metal halides, represented by two centimeter-sized, noncentrosymmetric organic-inorganic metal halides (OIMHs), namely H12C4N2CdI4 (P212121) and H11C4N2CdI3 (Cc). H12C4N2CdI4 is the first to be prepared, and its structure contains a CdI4 tetrahedron, which led to a poor NLO performance, including a weak and non-phase-matchable second harmonic generation (SHG) response of 0.5 × KH2PO4 (KDP), a small birefringence of 0.047 @1064 nm and a narrow bandgap of 3.86 eV. Moreover, H12C4N2CdI4 is regarded as the model compound, and we further obtain H11C4N2CdI3via the replacement of CdI4 with a highly polarizable CdNI3 tetrahedron, which results in a sharp enhancement of SHG response and birefringence. H11C4N2CdI3 exhibits a promising NLO performance including 6 × KDP, 4.10 eV, Δn = 0.074 @1064 nm and phase matchability, indicating that it is the first OIMH to simultaneously exhibit strong SHG response (>5 × KDP) and a wide bandgap (>4.0 eV). Our work presents a novel direction for designing high-performance NLO crystals based on organic-inorganic halides and provides important insights into the role of the hybridized tetrahedron in enhancing the SHG response and birefringence.

SELECTION OF CITATIONS
SEARCH DETAIL
...