Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Nanosci Nanotechnol ; 18(4): 2732-2737, 2018 Apr 01.
Article in English | MEDLINE | ID: mdl-29442950

ABSTRACT

Flexible and compressible temperature sensors are highly desired for artificial skin and epidermal electronics. Here we demonstrated a flexible and compressible resistive temperature sensor using hierarchically buckled carbon nanotube/rubber bi-sheath-core structure (a buckled carbon nanotube outer sheath and a buckled rubber inner sheath wrapped around a rubber fiber core). When heated, lateral contacts of the adjacent buckles increase, resulting in electrical resistance decrease and serving as highly sensitive temperature sensors. This bi-sheath-core fiber temperature sensor showed high linearity, good repeatability, large negative temperature coefficient of resistance (NTC = -54.7/°C), and insensitivity to compressive deformations (up to -20% strain). The NTC and temperature dependence of percent resistance change can be easily tuned by modulating the buckling bi-sheath-core structures such as varying the number of nanotube layers and the rubber sheath stiffness.

2.
Polymers (Basel) ; 10(4)2018 Mar 28.
Article in English | MEDLINE | ID: mdl-30966410

ABSTRACT

The increasing demand for wearable glucose sensing has stimulated growing interest in stretchable electrodes. The development of the electrode materials having large stretchability, low detection limit, and good selectivity is the key component for constructing high performance wearable glucose sensors. In this work, we presented fabrication of stretchable conductor based on the copper coated carbon nanotube sheath-core fiber, and its application as non-enzymatic electrode for glucose detection with high stretchability, low detection limit, and selectivity. The sheath-core fiber was fabricated by coating copper coated carbon nanotube on a pre-stretched rubber fiber core followed by release of pre-stretch, which had a hierarchically buckled structure. It showed a small resistance change as low as 27% as strain increasing from 0% to 500% strain, and a low resistance of 0.4 Ω·cm-1 at strain of 500%. This electrode showed linear glucose concentration detection in the range between 0.05 mM and 5 mM and good selectivity against sucrose, lactic acid, uric acid, acrylic acid in phosphate buffer saline solution, and showed stable signal in high salt concentration. The limit of detection (LOD) was 0.05 mM, for the range of 0.05⁻5 mM, the sensitivity is 46 mA·M-1. This electrode can withstand large strain of up to 60% with negligible influence on its performance.

SELECTION OF CITATIONS
SEARCH DETAIL
...