Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Biomech (Bristol, Avon) ; 110: 106132, 2023 12.
Article in English | MEDLINE | ID: mdl-37924756

ABSTRACT

BACKGROUND: Proximal junctional kyphosis is a common long-term complication in adult spinal deformity surgery that involves long-segment posterior spinal fusion. However, the underlying biomechanical mechanisms of the impact of osteoporosis on proximal junctional kyphosis remain unclear. The present study was to evaluate adjacent segment degeneration and spine mechanical instability in osteoporotic patients who underwent long-segment posterior thoracolumbar fusion. METHODS: Finite element models of the thoracolumbar spine T1-L5 with posterior long-segment T8-L5 fusion under different degrees of osteoporosis were constructed to analyze intervertebral disc stress characterization, vertebrae mechanical transfer, and pedicle screw system loads during various motions. FINDINGS: Compared with normal bone mass, the maximum von Mises stresses of T7 and T8 were increased by 20.32%, 22.38%, 44.69%, 4.49% and 29.48%, 17.84%, 40.95%, 3.20% during flexion, extension, lateral bending, and axial rotation in the mild osteoporosis model, and by 21.21%, 18.32%, 88.28%, 2.94% and 37.76%, 15.09%, 61.47%, -0.04% in severe osteoporosis model. The peak stresses among T6/T7, T7/T8, and T8/T9 discs were 14.77 MPa, 11.55 MPa, and 2.39 MPa under lateral bending conditions for the severe osteoporosis model, respectively. As the severity of osteoporosis increased, stress levels on SCR8 and SCR9 intensified during various movements. INTERPRETATION: Osteoporosis had an adverse effect on proximal junctional kyphosis. The stress levels in cortical bone, intervertebral discs and screws were increased with bone mass loss, which can easily lead to intervertebral disc degeneration, bone destruction as well as screw pullout. These factors have significantly affected or accelerated the occurrence of proximal junctional kyphosis.


Subject(s)
Kyphosis , Osteoporosis , Pedicle Screws , Spinal Fusion , Adult , Humans , Lumbar Vertebrae/surgery , Thoracic Vertebrae/surgery , Biomechanical Phenomena , Kyphosis/etiology , Kyphosis/surgery , Osteoporosis/complications , Spinal Fusion/adverse effects , Range of Motion, Articular , Finite Element Analysis
2.
Clin Biomech (Bristol, Avon) ; 94: 105621, 2022 04.
Article in English | MEDLINE | ID: mdl-35299117

ABSTRACT

BACKGROUND: Proximal junctional kyphosis is a known complication of posterior long-segment thoracolumbar fusion. Here, the biomechanical effectiveness of ligament tethers strengthening and vertebral body augmentation, in proximal junctional kyphosis prevention was explored using the finite element analysis. METHODS: Based on a validated model of T1-L5 with the pedicle screw system instrumented T8-L5, strengthening models with different strategies were created to assess the range of motion in proximal vertebrae, vertebrae stress, pedicle screw stress, and pressure on intervertebral discs during extension, flexion, lateral bending, and axial rotation motions. Strengthening strategies included two- and three-level posterior ligament tethers (TE-T7-T9 and TE-T6-T9), and tethers with T7 &T8 vertebral body augmentation (TECE-T7-T9 and TECE-T6-T9). FINDINGS: Compared to the spinal fusion model, the ligament tethers strengthening significantly reduced the flexion-extension range of motion difference among the proximal vertebrae. During the flexion-extension motion, the T8 vertebra stresses in the TE-T7-T9, TE-T6-T9, TECE-T7-T9, and TECE-T6-T9 models were distinctively reduced, the values decreased by 26.8%, 28.3%, 28.8%, and 9.6%, respectively, during flexion, and by 21.9%, 35.2%, 23%, and 18.6%, respectively, during extension. In the strengthening models, the maximum stresses on the T7/T8 intervertebral disc in the TE-T6-T9 model were reduced by 13.8% during flexion and by 14.7% during extension. INTERPRETATION: Based on our results, the ligament strengthening configuration of the three-level posterior tethers produced a more gradual transition in range of motion, vertebrae stresses, and intervertebral discs stress between the fused and non-fused segments, especially during flexion-extension, which may significantly decrease the proximal junctional kyphosis biomechanical risk.


Subject(s)
Kyphosis , Spinal Fusion , Biomechanical Phenomena , Humans , Kyphosis/prevention & control , Kyphosis/surgery , Ligaments/surgery , Spinal Fusion/adverse effects , Spinal Fusion/methods , Thoracic Vertebrae/surgery
3.
Clin Biomech (Bristol, Avon) ; 87: 105415, 2021 07.
Article in English | MEDLINE | ID: mdl-34174675

ABSTRACT

Background Proximal junction kyphosis is a common clinical complication of posterior long-segment spinal fusion and vertebral body augmentation method is one of the effective approaches to prevent it. The purpose of this study was to explore the biomechanical effect of proximal junction kyphosis after posterior long-segment thoracolumbar fusion with different vertebral augmentation schemes using finite element analysis. Methods 3D nonlinear finite element models of T1-L5 spine posterior long-segment T8-L5 thoracolumbar fusion combined with T7, T8 and T7&T8 vertebral bone cement augmentation were constructed from human spine CT data and clinical surgical operation scheme to analyze the von Mises stress in the vertebrae, intervertebral discs pressure and pedicle screws system loads under the flexion, extension, lateral bending and axial rotation motion. Findings Compared with thoracolumbar posterior long-segment fusion model, T7 maximum stress in T7, T8 and T7&T8 vertebrae augmentation models were reduced by 8.64%, 7.17%, 8.51%;0.79%, -3.88%,1.67%;4.02%, 5.30%, 4.27% and 3.18%, 3.06%, -6.38% under the flexion, extension, lateral bending and axial rotation motion. T7/T8 intervertebral disc pressure in T7, T8, T7&T8 vertebral augmentation models were 36.71Mpa,29.78Mpa,36.47Mpa;22.25Mpa,18.35Mpa,22.06Mpa;84.27Mpa,68.17Mpa, 83.89Mpa and 52.23Mpa, 38.78Mpa,52.10Mpa under the same condition. The maximum stress 178.2Mpa of pedicle screws is mainly distributed at the root of screw. Interpretation Thoracolumbar posterior long-segment fusion with proximal double-segment vertebral augmentation should be recommended to prevent proximal junction kyphosis than single-segment augmentation. Simulation results can provide theoretical foundations and assist surgeons in selecting the appropriate operation scheme.


Subject(s)
Kyphosis , Pedicle Screws , Spinal Fusion , Biomechanical Phenomena , Finite Element Analysis , Humans , Kyphosis/diagnostic imaging , Kyphosis/etiology , Kyphosis/surgery , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Range of Motion, Articular , Spinal Fusion/adverse effects , Thoracic Vertebrae/diagnostic imaging , Thoracic Vertebrae/surgery , Vertebral Body
SELECTION OF CITATIONS
SEARCH DETAIL
...