1.
Eur J Ophthalmol ; 32(3): 1810-1813, 2022 May.
Article in English | MEDLINE | ID: mdl-34658287

ABSTRACT

PURPOSE: To describe a novel technique in unfolding an endothelium-in Descemet membrane (DM) graft. METHODS: New surgical technique description. RESULTS: We describe a novel technique that allows immediate and controlled unfolding of the endothelium-in Descemet membrane graft that was successful in 5 of our DMEK patients. It is essential to acquire this "side press-and-release" technique when the graft does not unfold spontaneously as expected. CONCLUSIONS: This controlled and simple manoeuvre is an efficient and safe method of unfolding an endothelium-in DM graft.


Subject(s)
Descemet Membrane , Descemet Stripping Endothelial Keratoplasty , Cell Count , Descemet Membrane/surgery , Descemet Stripping Endothelial Keratoplasty/methods , Endothelium, Corneal/transplantation , Humans , Visual Acuity